Having problems with your Vacuums ?

Losing sucking power, the unitbarely lifts tissue paper up off the floor and in to the unit. The sucking power is not what it used to be. Clogged perhaps?


Answers :

Your filters are getting clogged. It sounds like you have a bagless!? You will need to replace or clean your hepa filter. It is usually located inside or underneath of your canister. It would also be good to clean the rest of your filters also.
Repair Help & Product Troubleshooting for Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Losing sucking power, the unitbarely lifts tissue paper up off the floor and in to the unit. The sucking power is not what it used to be. Clogged perhaps?


Your filters are getting clogged. It sounds like you have a bagless!? You will need to replace or clean your hepa filter. It is usually located inside or underneath of your canister. It would also be good to clean the rest of your filters also. ... Vacuums

Attachment problem used a new unit w/attachment for 5 minutes...dispensed solution in a powerful triangular fashion. Then the fluid quit dispensing out of the attachment nozle amost like the pump quit working. Primed the unit several times w/ no success. checked for clogs. can't tell if the floor portion is "pumping' or just dribbling solution onto the floor with the trigger. can see no leaks at this point. unit worked for about 5 minutes on apholstery


Make sure everything is filled and secured tightly, if this a new unit it should be something simple ok, also check where machine folds down that the solution hose is not being pinched its right behind the dirty water tank ... Hoover SteamVac F5914-900 SpinScrub Upright Vacuum

I have a Bissell ProHeat 2X which releases the water/shampoo mix fine, and will suck up using the hose, but will not suck up using the main floor unit. Have checked it all out, and there do not appear to be any blockages. Help please


The vacuum on its back then look under the front where the water comes\015\012out, you will see few little round holes now the chances are these\015\012holes are blocked so get something long like a pin and poke these holes\015\012through you should ... Vacuums

No power There appears to be no power to the floor unit. There are no clogs anywhere.


Those have a tendency to short out in the wands. Use a test light or meter to find out where the power stops. Test lower wand first then upper then hose, then unit. Replacement wands are available, there's really no fixing them. I'll include a link t ... Kenmore 25512/ 25513 Progressive Canister Vacuum

My Dyson has suddenly starting making this LOUD, horrible sound when I am using it on the carpet setting. However, when I use it on the floor setting, I do not get this noise. Also, I think the 'sucking' power is not as strong.


You need to check the beater bar on the bottom and the hose from the beater to the canister. You may have something stuck in the beater system. ... Dyson DC07 Bagless Upright Cyclonic Vacuum

We have a Beam1500 central vac. It sucks stuff off the floor, but then just clogs in the head of the unit.


The head itself is likely the power head..,which is sweeping but the neck is probably clogged. Detach your wand and look thru. Drop a coin thru your hose handle and shake thru the other end. If these are clear the issue is the head.Then check t ... Beam Industries 750 Classic Bagless Central System Cyclonic Vacuum

I have a hoover 3000 i have not used in awhile, and since I removed a large rug, I would like to use it again on my slate floor. HOWEVER, I cannot get it to pick up ANY water in the water recovery unit......it is dry, dry, dry. I have put in a new filter, cleaned the nozzle unit, the scrubber , and reconnected both the recovery unit and the water unit several times, but to no avail. I would like to get a graut attachment a well as replacement part, but since I can't get the basic unit to work, I


Have you made sure the plastic filter cover with the round hole in it that covers the filter is in place ( part # 59177096 ). This piece seems to get lost, and without it there is no pick-up. The other common problem is that the wheel assembly has be ... Hoover Floormate H3000 Upright Wet/Dry Vacuum

Electrolux Centralux I have a Electrolux Centralux. When I plug the hose in at one of the wall outlets the motor will not start. If I go to the motor and slap the unit it will start.....then...it will not stop unless I unplug the power cord to the motor. If I plug the power cord back in, the unit will not restart until I slap the motor unit again. The unit has only been used 20 - 30 times. Any suggestions?? Thanks, Bruce


I dont know if you had your unit looked at yet but it sounds like the Power module is going. I repair the machines so I know some of the work. ... Electrolux Centralux Vacuum

Our Dyson DC28 won't turn on. I used the machine earlier on today emptied the unit and put it back on charge. 5 hours later have gone to use the unit again, however now seems to have no power to i


... Dyson DC28 Animal Bagless Upright Vacuum

I recently bought an upright MC-E4061 and have a problem with the paper filter clogging prematurely, it needs weekly cleaning. The filter clogs too easily with the main plastic bowl having very little debris! Our older panasonic, used daily, is not problematic. Please could you advise as the paper filter is time consuming to clear.


... Panasonic Vacuums

HI, I have a Kenmore 25813 and it seems like there is an intermittent short. When I have the extension wand on and the power floor attachment on, when it rotate the wand the light cuts out and so does the power floor attachment, when I twist it back it comes on again. I don't have this problem if I remove the wand and just use the crevice tool with the hose. Any idea where the short might be and can I fix it myself? Thanks. Gary


This is common you may have a short in the contacts from the handle to the wand or a break in the cord that goes into the powerhead ... Kenmore 25812 / 25813 Progressive Bagged Canister Vacuum

We have a Kenmore canister vacuum cleaner 25614504. It has in intermittant light and power flicker in the power mate unit as it is moving over the floor. This behavior can be simulated by jiggling the power cord where it eners the power mate. I do not know how to enter the power mate to see if there is a loose wire.


... Kenmore 28614 Canister Vacuum

The power brush floor rug attachment on my Eureka 6997 A Oxygen Canister Vacuum goes on an off as I use it. I replaced the The power cord from the handle has 2 plug in connections: 1 at the handle / upper wand 1 at the lower wand top of the power brush attachment I replaced the entire wand assembly and it worked great for a year or so and now it's doing the same thing again. I was told to keep the power switch on the handle set to off when connecting the power brush attachment or it will bu


This is from the prongs not making a good connection causing an arch inside the plugg causing what looks like rust on the plugg. I would try snugging up the connection by squeezing the female section to get a better connection on the prongs when it i ... Vacuums

I have a Hoover Elite Rewind vacuum. Actually,this is my second one. However, after about 4 months of use, it emits a "sour" smell when I'm using it. I empty the cannister before each use and clean out the filter monthly. My house has mainly hardwood floors, so I typically only use it on area rugs and 2 small carpeted rooms. Is there any way that I can get rid of the smell? I've tried putting a dryer sheet in the cannister, but this gets stuck in the filter mechanism. Also, carpet fresh clogs th


Does it smell like an electrical burning odor? could very possibly be the motor going bad already. ive seen it happen. but if not try freshwave odor absorbing pearls. i carry it in my store and we do have shipping. Truly the only thing you should use ... Hoover U5507900 Elite Rewind Bagless Upright Vacuum

Help Please help,I do not have a how to use guide. Can you tell me how to use this thing?It is a "Bissell- Power Steamer- Pro heat Plus."It was a gift (used) with out a guide.I do not want water on my floors or carpet so I need to do this right.Thank you so much Sandra


Try this\015\012http://www.fixya.com/support/p49884-bissell_7920_proheat_pro_tech_upright/manual-17858 ... Bissell 7920 ProHeat Pro-Tech Upright Wet/Dry Vacuum

Hoover SteamVac Plus 1200 upright hot water extractor Water/carpet cleaner applying o.k. Suction on the "floor" does not work. Suction on the hand tool works somewhat, but water is not collecting in the bucket. There is suction coming from the floor but water is not going into the bucket. It does not appear to be clogged because I can feel with my hand that air is flowing from the floor. The water is not being sucked into the bucket.


... Hoover Vacuums

Our unit is 7024A Electrolux Oxygen 3 - it seems to work great but suddenly, the head or 'power brush' or whatever it is called - has died. I checked by removing the hose and plugging it directly into the body, but it is still dead. Without that motorized head working, the vacuum is useless. Is it worth replacing? The unit is only about 1 year old and has seen light use only. Very frustrating, since it was the most expensive unit in the store:(


... Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum

Miele, Flamenco II. 2 probs. 1. the head brush is not turning when I put it on the floor. If I pick it up to look inside...the brush is spinning fast..I put it down on the floor...the head does not spin at all. 2. The suction power has dropped significantly. The suction used to be so intense, the head would **** itself to my floor and hold on...now, hardly any suction at all.


Sounds like the belt is not on correctly on the beater brush or the belt is worned out now for the suction check filters or bags that need to be empty or clean ... Miele Vacuums

My bissell proheat 2x carpet cleaner is not spraying from the bottom or sucking up when turned on. The hand tool works just fine. I have made sure it was on floor cleaning when I used it to try and clean my carpet. the busshes are working but nothing else is happening this cleaner is about 21/2 years old and has only been used maybe 5 times so it has not had alot of use.


Hi,Here is a tip that will give you all the information you need to fix your BissellProheat Vacuum Problem.Bissell Proheat Upright Wet/ ... Bissell 9500 ProHeat 2X CleanShot Upright Deep Cleaner, Red Berends Vacuum

My Prosine 2.0 display panel displays Panel Fault: Memory error and the display error as well as all LEDs are off. The unit looks as if it has no power to it. I reset (power off.power on) the Prosine and all LEDs on the display (except for the back lit display) turn on for about 3 seconds then all go off again. I am able to use 120v RV Resort power and all 120v equip works. The Coach batteries do not charge and were low. I charged the Coach batteries with an external charger. The charge works ye


... Vacuums

I have a Hoover SteamVac F5914-900 SpinScrub... The last time I used the hand tool attachment, it worked fine. Just tried to use it again, and now I only drips of water will come out of the hand sprayer, if that. I have tried prepping it for up to 15 seconds like the manual says... no luck with that. Also it is making a big puddle on the floor, probably because the brushes on the main unit keep spinning when I am trying to use the hand tool which I dont think they are supposed to do? Can a


The brushes can be turned off on most of them via a switch on the hood. There shouldn't be water coming out onto the floor unless you are pulling the trigger at that top. You probably broke this when attempting to use the tools. ... Hoover SteamVac F5914-900 SpinScrub Upright Vacuum

I just bought a Bissell Proheat Plaitnum 2 powersteamer at a yard sale that looks like it has hardly been used. So far I'm only able to get the water onto the carpet by using the hand tools. When I put it on floor mode it will suck up the water but not dispense it.


Hi,Here is a tip that will give you all the information you need to fix your BissellProheat Vacuum Problem.Bissell Proheat Upright Wet/ ... Bissell 1698 PowerSteamer ProHeat Upright Wet/Dry Vacuum

Bought today a used rca rp3721a clock radio without the manual. need user manual to adjust all the settings, for example TIME, ALARM TIME, ALARM ON AND OFF, radio or "beeper" alarm on, entire unit on and off without unplugging it from shore power,and anything I haven't thought of up to here. The unit is RCA Model RP3721A clock radio, and appears to be functional. Our problem seems to be "the nut behind the wheel". e-mail: [email protected]


Hello,I advice you check the links below to search for the\015\012manual of your device, the link contain almost virtually all the manuals of all \015\012device.manualsonline.comORmanualnguide.com ... Vacuums

Old Sanyo 1500 watt "Power Control" vacuum cleaner. I need to remove the plastic covers that are attached to the on/off switch and the power cord recoil. This will allow me to remove the retaining screws for the upper motor cowling. The motor and wiring is clogged with wood dust and I want to blow the dust out using compressed air.


... Sanyo Vacuums

Extreamly Loud this vaccuum has great sucking power I have used it about 4 times it is very loud it sounds like a screeming banshee. It actualy hurts your ears to use it. the filters are new the roller is clean and rotates freely what is the problem with it?


Most likely you have a bad motor bearing. It's a pretty common problem with vacuums of this type... a good way to check is to open the bottom where you replace the belt, and look at the motor pulley. If it's blued, your bearing is most likely generat ... Eureka 2971AV EZ Kleen Bagless Upright Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.1324 seconds