Having problems with your Vacuums ?

I have a Eureka Central Vac CV1601b. The motor does not stop unless the Unit is unplug from the electrical outlet. Any Idea?.I removed the control unit to check if there was disconnected wires or burnt wires. Everything look normal. The circuit board does not show area that overheated. There seem to be 2 relays. Likely one of the two went bad. What do you think.

Answers :

If the unit is relay controlled, there is always the possibility that when the unit was turned on, the relay contacts welded themselves shut making the power button ineffective.
\015\012If you're familiar with relay pinouts, with the unit unplugged, verify the contact closures with an ohmmeter or continuity checker. With the unit unplugged, the relay contacts should be in their "normal" state (probably open).
\015\012Try gently tapping the relays to see if it can be freed that way. If that works, there's nothing stopping them from welding themselves together again. The relay may need replacement.
Repair Help & Product Troubleshooting for Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

I have a Eureka Central Vac CV1601b. The motor does not stop unless the Unit is unplug from the electrical outlet. Any Idea?.I removed the control unit to check if there was disconnected wires or burnt wires. Everything look normal. The circuit board does not show area that overheated. There seem to be 2 relays. Likely one of the two went bad. What do you think.

If the unit is relay controlled, there is always the possibility that when the unit was turned on, the relay contacts welded themselves shut making the power button ineffective. \015\012\015\012If you're familiar with relay pinouts, with ... Vacuums

Riccar 1700 melted connector to circuit board...

It might be an easy fix but should be done by a qualified Riccar dealer. ... Riccar Vacuums

Cleaning solution does not come out of the rotating cleaning head or the hand-held nozzle the solution pump seems ok but does not run (electrical continuity check between the two leads on the pump show very low resistance so they seem to be intact) - no dirt or blockage is apparent (it is a very simple device with 1 moving part wires to the pump also pass a continuity check THERE IS NO VOLTAGE on the pump leads from the control circuit board when I turn on the "manual" cleaning mode - a

You can contact Bissell directly at the following\015\012\015\012For UK inquiries:\015\012Monday - Thursday 9 am — 5 pm\015\012Friday 9 am — 4 pm\015\012\015\012BISSELL Homecare (Overseas) Inc ... Bissell SpotBot Robotic Wet/Dry Vacuum

I have model Model # 11635923500 Sears Kenmore--the unit runs but the brush does not turn--do I need circuit board or wiring ?

... Kenmore Vacuums

I have replaced the circuit board twice on my hayden 2400 and after working for 24 hours the circuit board then fails, with no signs of it tripping. Everything is wired in correctly the supplier is unsure of the problem but leading up to me replacing the circuit board the machine itself had became intermittent switching on and off while hoovering

Disconnect the wiring from the unit, and go back and plug in your hose. \012\012Get a volt tester and test the voltage coming from the lines at the machine. It should read 0 volts. Check both AC and DC voltage. \012\012Also, c ... Hayden Industries SuperVac 2400 Central System Vacuum

Dc15 fuse The roller brushes on my dc15 stopped working..I checked the obvious and then noticed that the 2 amp fuse was blown on the circuit board . I've replaced it with the same type bought from Maplins but it keeps blowing .. I tested the yellow an blue wires leading from the circuit board to the roller brush head and the are in tact and I can run a current through them ... Any thoughts from anyone .? Your help would be. Appreciated thanks Lee

Hi Lee,I'm sorry to hear you're having difficulty with your DC15. If you'd like some help, please give us a call on 0800 298 0298 - we may be able to resolve the issue with some troubleshooting over the phone.Best wishes,Jack ... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

Hi, my circuit board resistors are burnt due to my re-wiring the resistor switch. How do I fix this - S3755 wiring diagram?? need to know the correct resistors or get a new board

The only way is to get a replacement board. even the dealers are not provided with that level of wiring diagrams. ... Hoover S3755 WindTunnel Bagless Canister Vacuum

Model # 5770 the brush motor runs and shuts down after a few seconds...Turn unit off and the brush again will run for a second or two...If I don't turn unit off brush will not start up..Could it be the printed board..the motor brushes..or the wiring that goes from the printed board to the main motor...Thank you

Seems like your unit goes into failsafe because it detects something wrong. Well you should check the brushes and replace them if they are worn out. Also check the wiring for shorts etc, becaue the unit maybe tripping due to an overload. The printed ... Bissell Vacuums

The battery will not charge in the sweeper. I can remove the battery and wire it to the power supply for charging and it will charge up and run the sweeper. So the power supply and the battery are both good. Obviously there is a circuit failure in the on board charging control. Anyone know a fix or a likely faulty component? I had a shark handheld about 8 years ago and it developed the same problem. I examined the little circuit board inside but saw no visible indications that would isolate t

... Euro-Pro Cordless Bagless Upright Sweeper - Blue/Gray

I need a relay board for a Nutone CV 450 12.6 amp dual motor vacumn unit. Where can I locate one? Part #??? Unit will run by itself, then shut off. Unit wll not run at all. It has a mind of its own. Crossed a couple of wires on one of the relays and the unit runs smooth as silk. I assume its the relay, but can't locate part number.

Why not just replace the relay? Part number 1094117... ... Broan-NuTone CV450 Central Bagged Central System Vacuum

Eureka Boss Smart Vac 4870 evidentally overheated. Allowed unit to cool and observed a spark/smoke at outlet when it was replugged into the power outlet. Unit will not power up now. Circuit breakers in the home are fine. Is there a fuse that can be replaced in the unit? Does the unit need to be serviced? Is there a Eureka Authorized Service Center in Orlando, Florida?

Seems Eureka is putting faulty, insufficient wiring in many models, most especially my model (if you do a search of this site, you will be how many people have experienced fried wires and switches). There should be a class-action lawsuit in my opini ... Vacuums

I cannot charge my two year old electrolux pronto. I purchased a brand new hand held vacuum for it, but even the new one does not charge. When I plug in the cord nothing happens. If I turn on either the long handle or the portable unit within the long unit, the blue charging light comes on for a few seconds, then out. This tells me that the circuit is intact without a broken wire somewhere. I took it all apart carefully and could see nothing broken or out of place. On re-constructing it, it

It must be the charging transformer. We have already ruled out the vacuum unit. Unfortunately the transformer is not a serviceable part, and will need to be replaced. ... Electrolux Pronto 2-In-1 Stick/Hand Vacuum - Cayenne

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?

... Vacuums

Our vac unit is 1 1/2 yrs old. It will not shut off, I've tryed your problem solver by hitting the unit with a hammer. I'm an electrician I was surprise by this advice but never the less I did it and it doesn't turn off. The model # E130J I believe it's the printed circuit board, please advise Thanks Doug

Your machine is still under warranty if you purchased it new (5 years). Take it to the shop you purchased it from (Aerus Electrolux), or call them for free pick up, and ask them to repair it. The boards do go bad occassionally. It could also be t ... Electrolux Centralux Vacuum

I just received a Sharper Image SI724 Hybrid GP air purifier and it will not turn on. There is a green light that comes on at the bottom front of the unit, but the light on the top do not show any color and do nothing. I have tried to clean the fine wires to no avail. Is it just a bad unit or is there an in-home fix I could use?

If you just got it and it doesn't work ... you should return it for an adjustment. If you fool with it, you will probably void any warranty there may be on the device. ... Vacuums

Acces to circuit board on dyson dc25 printer

... Dyson DC25 Vacuum

Simplicity Jack turns off repeatedly during use. Vacuum doesn't feel hot. I have opened up the vacuum and have checked wiring etc.. Is there a faulty censor on the circuit board. How do I check or replace needed part?

... Electrolux Oxygen 3 Upright Vacuum Cleaner - EL5035 Vacuum

To : admiralstopf I have a U-Line clear ice maker UCLR2060B40. The authorixed service center has been trying to fix my unit since October to March. They have replaced the circuit board 2x and the Thermister and rain tube. They clai they were able to get it to work on their bench (not sure if true) but they can not get it to work in the house. They gave up and refunded my payment. Now what? Jonathan

Unfortunately we are not affiliated with any manufacturers. What I would do at this point is to contact the manufacturer of your ice maker and let them know what has transpired when you attempted to have their authorized repair center fix your issue. ... Vacuums

The last time the vacuum cleaner was used the outlet sparked causing it to smoke when turning on vacuum cleaner. I replaced the outlet and plugged it in and things seemed o.k. Today I turned on the vacuum, it stayed on for a mili second and went off. I checked the switch on the vacuum and it showed voltage coming and going, but would not turn on again. I checked all the wires in the area of the switch all seemed o.k. I thought maybe there might be a short in the cord. When I went to plug

... Sharp Twin Energy EC-12TWT4 Bagged Upright Vacuum

Rewiring kenmore vac with circuit board need wiring diagram for mdl 116.22271501c

... Kenmore 23313 Whispertone Bagged Canister Vacuum

Our Hoover U8172-900 brush motor is not working. Do you have a wiring diagram so I can determine if the motor circuit board is the problem or the motor?

No diagrram is necessary unless you have dismandled.\012Check if the brushes are touching the mtor commutator. If not you can easily remove both the brushes and polish the surface evenly .Insert only after cleaning the motor commutator till the ... Hoover Vacuums

I fear the motor has failed on my Electrolux Oxygen EL6988D. Just six months after the warranty expired, I was vacuuming when it suddenly stopped. There was no blockage in the tube and it wasn't working hard or long . . . it just stopped. I looked around the Internet and it appeared that many similar Electrolux units have a fuse. I hoped my problem might just be a blown fuse, so I took the machine apart. There are two small printed circuit boards, but no fuse. There is an in-line

Hi,\015\012\015\012I don't think you need a new motor, but please stop testing the machine with live power. It's dangerous and unnecessary. Your tests indicate to me that the motor is fine and your thermal-fuse - I think this is wh ... Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum

I have a Hayden SuperVac 3600, almost 10 years old. The unit still runs, but now when I switch to the power nozzle, it doesn't have power to turn that. I think this happened once before and maybe they replaced a circuit board(?). We took it to a local repairman this time and he says he can fix it temporarily with a new cartridge, but that he won't promise it won't happen again soon.....

The hose has fuseable link inside, generally a 3-7 amp. It is at the wall end underneath the hose cuff. Easy to replace as it crimps in line. If you have a meter you can also test the detachable hose to wall cord for continuity, then check the hose t ... Hayden Industries SuperVac 6000 Central System Vacuum

SubBrand name 'Exmork', 5 Kw Sine wave inverter Intermittently, breaks into a spurious mode which causes it to draw excessive current while the output waveform becomes seriously corrupted with severe transient spikes close to the crossover point. We have available oscilloscope images showing the problem graphically. We have four of these inverters out in the field, and they all exhibit the problem from time to time. The fault has precipitated failures in the Power-board module in two units

Had similar problems with my inverters a while back tried to sort it out myself all to no avail. Eventually found out it was a problem from the manufacturers and all that were produced had the same fault. Had to change my brand to Su-Kam inverters. I ... Vacuums

I have an Eureka Express canister vacuum - I believe it's model 8284 - that just stopped working. Plug it in, turn it on, and absolutely nothing happens. I took it to the local sew and vac place and they say it's a circuit board that is no longer available. I've looked at all the parts lists and diagrams for that vacuum and I would swear there isn't a circuit board there. (I wouldn't have even thought that in 1989 they would have used circuits.) In any case, I absolutely love this machine a

Given the age of the machine weighed against you fondness for it, unless you can find a fault with either the switch or the cord, there is little else that can be done. With time the electrical lead can break down and one o ... Electrolux Vacuums