Having problems with your Vacuums ?

Hoover Wind Tunnel U5720-950

\015 I was sucking up kitty litter and the vacuum stopped working. After letting the vacuum cool for an hour, I tried to run it and it quit after 3 to 5 seconds with a nasty burning smell.\015\012\015\012I tried to take it apart to clean the motor out but can't figure out how to get to the motor.\015

Answers :

Be sure it has a new bag and fillter, or try running it on a clean surface with the door off. if it still has a burn smell and only runs a few seconds the motor is probably bad. expensive and difficult to access. kitty litter has moisture in it and the vac motor is strong enough to pull the moisture out and draw it through the motor which will damage the commutator. kitty litter (and plaster dust) are stone dust composed and will pass some material through filters in to motors. for such jobs you should use a shop vac style machine , since they have a bypass motor that doesn't pass material through it.
Repair Help & Product Troubleshooting for Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hoover Wind Tunnel U5720-950


Be sure it has a new bag and fillter, or try running it on a clean surface with the door off. if it still has a burn smell and only runs a few seconds the motor is probably bad. expensive and difficult to access. kitty litter has moisture in it and t ... Vacuums

Hoover wind tunnel 12 amps motor 30.0


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Repplacing power cord on Hoover Wind tunnel (not self propelled)


I am thinking that the cord goes in on the back, just below the handle. Remove the handle, then from the front, remove the tool holder(#8), then you can get to where the cord comes in and hooks up.\015\012\015\012 ... Hoover U5753-900 WindTunnel Bagless Upright Vacuum

Need manual for hoover bagless wind tunnel


... Hoover Vacuums

Hoover Wind Tunnel


If this is new, you have a years warranty on it, take it for repair. Did you get the right belts, the numbers are 38528035 for the flat belt and 38528034 for the V belt. Also if you are catching something like a towel or area rug in the brush roll, ... Vacuums

Hoover Wind tunnel cyclonic is dead. Will not


... Hoover U5780-900 Windtunnel Cyclonic Bagless UprightVacuum

Hoover wind tunnel 2 bagless vacuum not working


Place handle in low position and turn cleaner over so bottom side is up.\015\012Remove the 4 screws in bottom plate and lift off.\015\012Look on the left side of the agitator brush. You should see the belt there. Remove agi ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Hoover wind tunnel


Did you check down by the brush roll for a clog in the dirt inlet. And is the brush roll turning freely, if it is being lugged down, it can cause the motor to overheat and the thermo protector will caught it off, until the motor cools down. But if ... Vacuums

How do you change the Hoover wind tunnel belts?


If you turn the vacuum over there will be (4) screws that hold on the base cover for the roller brush. Remove the screws and the cover and you can get to the belt(s). You can get replacement belts here: ... Hoover Company Wind Tunnel U53019 Upright Vacuum

Filter in Hoover Wind Tunnel Vacuum


Definitely not. Do not use water or any liquids to clean it. Te normal use life is 2-3 years keeping it maintained. You can clean it dry with the dust brush from your vac attachments. place in a plastic bag and tap it some folks even us an air compre ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Hoover Wind Tunnel ON/Off Switch


Replace the rocker switch inside the handle. Part #28161067, it's about $2.50. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover Wind Tunnel does not turn on


That is a pretty good lifespan for a hoover, but its probably the power switch that's bad. Hoover uses a very poor quality switch. It shouldn't cost to much to have it replaced ... Kenmore 33721 Upright Vacuum

My self-propelled Hoover wind tunnel vac. cleaner is hard to push


... Hoover Vacuums

Hoover Wind Tunnel U6433-900


The problem i see the most is that people have the setting on the front of the vacuumfor "floors" not carpet, switch it over and it will start as soon as the handle is released , if not try belts and finally motor burnt out. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Changing belts on Hoover wind tunnel U6401


Take off the bottom plate covering the brush roll, 4 screws. There are 2 belts, if you replace both, put the V belt on 1st, then stretch the flat belt over the motor shaft, then over the bigger pulley along side the V belt.\015\012\015\0 ... Vacuums

How to change the V belt on hoover wind tunnel U6435-900 ?


Below I have listed a link to the manual which has instructions and a link to the V belt you need.\015\012\011\011\011\011\011\011Windtunnel Manual ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover wind tunnel vacuum cleaner shuts off during use


Check the inlet down by the brush roll to make sure it isn't clogged. If not and the hose isn't clogged, then probably the thermo protector (part #28382093) maybe bad. It is mounted near the motor. Could be motor Part #43576188. But I would suspe ... Hoover U5444-900 5100 Wind Tunnel 15 Inch Wide Hepa Filter Bagged Black VacuumVacuum

I have a Hoover u6446-900 wind tunnel. The carpet...


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

I have a Hoover Wind Tunnel Supreme mach 3.9. It


Check the filter above the dirt tank. If you take out the dirt cup and look where in slides into the machine, there is a filter that is probably dirty. It can be cleaned or replaced ... Hoover Vacuums

Hoover wind tunnel vaccuum cleaner i need to know


... Hoover Vacuums

Repplacing power cord on Hoover Wind tunnel (not self propelled)


HiThis is HARD and you NEED electrical knowledge and IF NOT UP TO IT YOU COULD CAUSE PROBLEMS TO YOUR SELF AND OTHERS.You do not say what the problem is with the cord.If is it damaged then it needs to be replaced with a new one.and then ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover Wind Tunnel bagless- issue with turning on


Have you tried to plug the vaccuum in another outlet that is on another breaker? It could be the vaccuum tripped the breaker. Turn the breaker back on. The manual mentions the thermal protector could have been activated. If this happened it reset ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Hoover Wind Tunnel U6458-900 Self Propel doesn't work - via other expert advice here for other models of Hoover - I'm thinking it is the actuator that needs to be replaced as I can see the cable does not connect to anything on the bottom. My problem is - I can't get the cover off. Been trying for a couple of hours. I removed every screw I can seem to find but something is hold it down. I also am wondering if/when I do eventually get the cover off, would I need to replace the cable when I replac


On some models there are hook/springs that hold the cover of the base snug. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover wind tunnel not picking up properly - Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum


My turbopower 6200 does not seem to be picking up. The beater bar I don't think is working? ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Replacing a belt Hoover wind tunnel - Hoover Vacuums


You will find four screws under the bottom cover. remove these. remove the beater bar, loop new belt on bar on pulley area. install the bar and then pull the belt over the motor shaft. re-install cover. ... Hoover Vacuums