\015 The breaker on our beam model 167 central vac popped while in use. every time i try and restart it, it immediately pops again. What's the problem? Circuit board? Motor? overheating?\015

Answers :

How to install a new circuit board?
Http://geeksquad.fixya.com/ThreadView.aspx?prdid=0&thid=797869
\015\012Generic problem for all Vacuums
\015\012Beam Central Vac Breaker Pops
\015\012Posted by tinateggart1 on Jul 17, 2008
\015\012The breaker on our beam model 167 central vac popped while in use. Every time I try and restart it, it immediately pops again. What's the problem? Circuit board? Motor? Overheating?
\015\012Hello,
I would advise you to ALWAYS to FIRST UNPLUG YOUR VACUUM before beginning any service procedure. Chances are it is the relay switch on the inside of the Beam Central Vac, if it was a motor, it would not turn on @ all. If it was a circuit board, it may or may not be turned on, but if it will turn on and then pop your circuit breaker than it probably is the relay switch. Please, check with your local Beam vacuum cleaner dealer in your area or contact the Beam website or cust serv @ the phone number listed below. So if you need further assistance, please feel free to contact your local vacuum cleaner dealer in your area or in the yellow pages, or contact the factory phone number or website to further assist you with your questions.

\015\012http://www.beamvac.com/usa/ Owner Support
\015\012Customer Service 1-800-369-2326 Phone #
\015\012Email: [email protected]
\015\012Technical Support: [email protected]
\015\012Thanks, Don the Vac Man
Go Ahead. Use Us.



Repair Help & Product Troubleshooting for Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Beam Central Vac Breaker Pops


How to install a new circuit board? ... Vacuums

Installed new VX550C central vac unit today. Breaker at electric panel trips after unit is ran one time. Reset, use once, then breaker trips again at next use.


... Vacuums

I have to reset my Beam Central vac quite often!!!


Check to see if there is a clog in the system. Something is causing stress on your motor causing it to switch off. Or it could be the motor itself failing.First check for a clog, if you can't find anything wrong, call Beam for assistance ... Vacuums

I have a central vac beam model BM1372 the rug


... Vacuums

On my Air Vac model AV425A Central Vacuum System, I discovered the circuit breaker opened. When I close it, the vacuum motor goes on. It doesn't matter which position the on/off switch is on, it runs until I open the circuit breaker again.


... M&S Systems ZX7000 Bagged Central System Vacuum

Problems with Beam central vac


My Beam central vac has started turning off after about 10 minutes of use. I thought it was the hose, but the hose in the garage does the same thing, and I've also tried the other outlets, and the same. The canister was just emptied about two weeks a ... Beam Industries 2775 Serenity Plus Central System Vacuum

Beam central vac motor reset button keeps tripping


... Beam Industries 2900 Serenity Plus Central System Vacuum

Problems with removing "twist-off" bucket from beam central vac.


... Beam Industries 2775 Serenity Plus Central System Vacuum

Beam central vac motor reset button keeps tripping


... Beam Industries 2900 Serenity Plus Central System Vacuum

Everything new central vac nutone vx 550 turns on and off by itself it trips the circuit breaker suction is great at times at other times there is no suction i had different inlets the suction was fine then went to half it compacity tried to change the inlets only changed one the system does whatever it wants to do


... Broan-NuTone VX550 Bagged Central System Vacuum

I have a one year old Beam central vac. It has supervalves. The handle (connected to the hose stopped turning on the unit. The handle still powers the brush but no longer turns on the suction?


Http://geeksquad.fixya.com/ThreadView.aspx?prdid=0&thid=566201 ... Vacuums

My beater bar is struggling to turn. actually, it appears as though it is the motor that is struggling, as it slows down when going against the pile and the motor labours so much that it frequently fails to turn the bar until i lift it up again. the belt appears ok, and it is clean of hair etc. it is a 5 year old beam central vac. thanks, D


... Beam Industries 875 Classic Central System Vacuum

I need an operational manual for a beam central vac model 178. It came with the house and I need to take it apart and clean it. Does the filter thing inside the system come off. It is caked in dust and dirt and I think it is effecting the performance of the vacuum.


... Vacuums

Recently my central vac system started making a louder than usual and laboured sound when in uise, enough so that I took note and inspected the canister and motor while running. The motor was trowing off blue sparks and looked like it could 'POP' at any moment. I will not risk using it until I know what the problem is and how to repair it. My assumption is the motor needs to be replaced. The system came with the resale house I bought 3 yrs ago but I do not know the age of the system itself.


... Vacuums

Electrolux central vac powerhead (N106M) frequently tripping built-in circuit breaker. It seems to be only when pushing in one direction, why would the motor draw more current in one direction? (it doesn't seem to be related to carpet "grain")


Have you checked the roller brush. Thread, string, and hair wrapped around the brush will create stess on the motor, resulting in overheating and shut off. Clean the brush and try. ... Electrolux Centralux Vacuum

Beam central vac


Don't know the exact model, but it sounds like the low voltage relay is stuck. This will be inside the unit, probably mounted on a replaceable board. You may be able to temporarily free it with a quick tap on the top of the relay if you locate it. Bu ... Beam Industries 2775 Serenity Plus Central System Vacuum

Replacing relay board on beam central vac


... Vacuums

I have a model 1561 electrolux central vac..can i use a hose and accessories from a model 15448 model electrolux central vac to compliment my central vac unit


If the hose fits into the inlets, then there should be no problem. ... Electrolux Centralux Vacuum

Central vac our central vac will not work unless the main vac in the garage is switched on manualy.... its sucking fine but i have to switch it off at the main switch in the garage after i have used it normaly i just plug in the hose and vac away and it switches itself off we have just had cable installed with a fisher guy in the walls do you think that would be the problem thanks a lot


It is possible that the low voltage wiring that controls your central vacuum has been damaged during the cable work. You can check to see if the low voltage relay is working by shorting the two terminals together at the unit. Just disconnect the two ... M&S Systems AirVac AVP1200 Platinum Series Central Vac - 12,000 sq ft Bagged Central System Vacuum

How to unclog central vac pipe - M&S Systems AirVac AVP1200 Platinum Series Central Vac - 12,000 sq ft Bagged Central System Vacuum


... M&S Systems AirVac AVP1200 Platinum Series Central Vac - 12,000 sq ft Bagged Central System Vacuum

Hi I need help because I have a problem with my Electrolux Centralux Central Vac system in my house. When I plug the vac hose in the central vac socket at first I heard the motor running very gently with NO suction then after a minute or so it went completely dead and they is NO motor sound, suction, or anything happening what so ever. Can anyone tell me what this problem is???


Have you checked for a clog in the lines or in the hose? If there is no clog in the system anywhere, then your motor could be dying. ... Electrolux Centralux Vacuum

No suction I am getting no suction on my central vac at the vac. I do not believe that the piping is plugged up, the vacuum is not creating suction. What are the causes of no suction at the vacuum and how do I take the top half of the Nutone central vac off?


Use the guide at builtinvacuum.com/flowchrt.html to find the issue and solution. Most likely you need to test it without any filter and be sure the bottom of the unit is attached :) To get access to the motors you need to unbolt the very top sides. ... Broan-NuTone CV350 Performance Bagged Central System Vacuum

WIRING IN 24 VOLT INLET VALVE FOR CENTRAL VAC. I GET A CONSTANT ON. I HAVE TRIED MAY DIFFERENT COMBINATIONS BUT I CONTINUE TO HAVE MY CENTRAL VAC AS A CONSTANT ON? COULD IT BE THE 24V WIRE?


No, there is only two possibilities. One, the low voltage wires are touching somewhere in the system or two, the relay is stuck in the on position. To find out which it is disconnect the low voltage wire from the unit (theres two clips on the side) a ... Beam Industries Wet/Dry Auto Central System Vacuum

Broan-Nutone Built-in central vac. system. 1 1/2 years old. Motor will not come on on.


... Broan-NuTone VX475 Bagged Central System Vacuum

Central Vac will not turn on.


These problems are nearly exclusively caused by a bad circut board and replacing it is the fix. Bad boards can cause many different effects so its nearly impossible to be sure. The 9v signal wire is not enough to short out an entire unit so it is ... Easy Flo EF1400 Central System Vacuum