Having problems with your Beam Industries Wet/Dry Auto Central System Vacuum ?

WIRING IN 24 VOLT INLET VALVE FOR CENTRAL VAC. I GET A CONSTANT ON. I HAVE TRIED MAY DIFFERENT COMBINATIONS BUT I CONTINUE TO HAVE MY CENTRAL VAC AS A CONSTANT ON? COULD IT BE THE 24V WIRE?


Answers :

No, there is only two possibilities. One, the low voltage wires are touching somewhere in the system or two, the relay is stuck in the on position. To find out which it is disconnect the low voltage wire from the unit (theres two clips on the side) and then plug the canister in. If the it still runs with the wire disconnected then it is the relay board. If it doesn't then it is the low voltage wiring in the system. Good luck!
Repair Help & Product Troubleshooting for Beam Industries Wet/Dry Auto Central System Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

WIRING IN 24 VOLT INLET VALVE FOR CENTRAL VAC. I GET A CONSTANT ON. I HAVE TRIED MAY DIFFERENT COMBINATIONS BUT I CONTINUE TO HAVE MY CENTRAL VAC AS A CONSTANT ON? COULD IT BE THE 24V WIRE?


No, there is only two possibilities. One, the low voltage wires are touching somewhere in the system or two, the relay is stuck in the on position. To find out which it is disconnect the low voltage wire from the unit (theres two clips on the side) a ... Beam Industries Wet/Dry Auto Central System Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?


... Vacuums

Kenmore central Vac - where to connect low voltage wires?


Mosy central vacs have 2 spades close together that stick out on the side, usually where the circuit breaker and auto/manual switch is. This is where you plug the low voltage wires into. ... Vacuums

I have a Eureka Central Vac CV1601b. The motor does not stop unless the Unit is unplug from the electrical outlet. Any Idea?.I removed the control unit to check if there was disconnected wires or burnt wires. Everything look normal. The circuit board does not show area that overheated. There seem to be 2 relays. Likely one of the two went bad. What do you think.


If the unit is relay controlled, there is always the possibility that when the unit was turned on, the relay contacts welded themselves shut making the power button ineffective. \015\012\015\012If you're familiar with relay pinouts, with ... Vacuums

Need connector wires inside wand. Electrolux central vac. 16" wand 1 1/4" wand dia. Don't need wand, just the wires.


Go to a store like Lowe's and look in their electrical department. You need wire the same gauge size (stranded or solid) and comparable insulation. Hope this helps! ... Vacuums

I have FILTER QUEEN vac that a friend gave me because he unhooked the 5 wires coming from the motor and he didn't know where they when could I get photo of the wires coming from the motor and whe


I would go through the manufacturer for the diagram. ... Filter Queen Cheetah II Ash - MU305 Bagless Canister Vacuum

On my M&S Air Vac AV425 central vaccuum system, the system usually turns on by inserting the vaccuum hose into one of the vaccuum outlets. However, it now runs continuously. I am able to turn it off only by unplugging the vaccuum from the electrical outlet. I would like to know how to trouble shoot the problem or how to find someone who services Air Vac systems in the Bridgewater, New jersey area.


We are a central vacuum service company and we service all of new jersey. sounds like you have a short some where that keeps your unit running or it could be your relay module thats stuck our number is 908-721-7595 its j&j central vacuum services ... Vacuums

We have an Eureka The Boss Central Vac Model ACV2001B. When you plug in the vac the motor starts momentarily and then stops. What could be the problem? Thank you.


Most likely there is a short in the low voltage wiring in the hose. ... Vacuums

Kenmore Central Vac - Where to connect the low voltage wires


You need female spade connectors and most hardware stores should have them. ... Vacuums

Electrolux central vac, floor sweep malfunctioning


For 9.99 I'll tell you how I did it. Thankyou very much. ... Electrolux Centralux Vacuum

When trying to use my Hayden Model 3600 central vac when trying to turn on the unit runs for 1 or 2 seconds and shuts off and continues to do so while switched on. I have thoroughly cleaned the filter and dirk canister but the intermittent running still occurs. Any suggestions?


... Hayden Industries SuperVac 3600 Central System Vacuum

I have a NUTONE central vac, when I turn on the power, It sounds like its grinding glass and doesnt suction. Could it be that broken glass got caught in the motor and all I need to do is clean it, or is this the sound of a failed motor?


More likely it's something in the fan. However, I suggest taking it to a vacuum repair shop to make sure. Something could have got into the fan system and is making a racket, but the motor itself won't crunch up glass. ... Electrolux Central Vacuum

Central Vac Model 34834 600A series--amber light on constantly, even when the cannister is empty, why


... Vacuums

Continuous running My Eureka Central Vac will not turn off. I have to unplug it.


Central vacs have relays in them, some stand alone, others mount on a circuit board. A stuck relay causes this type of problem. At the unit disconnect the low voltage wires, plug in your unit, does it still come on, if it does then you have a bad ... Eureka 1810 Central System Vacuum

NuTone CV750 Central Vacuum won't shut off. The on/off switch on side of unit has no effect. Did continuity test on switch, it tests ok. I've disconnected the low voltage wiring at the side of unit, that had no effect.


I will assume that you disconnected the switch from the circuit when you did the continuity test -- that is really important.\015\012If so, then i think that the relay inside the top of the unit is stuck on, or the low voltage wires (inside the ... Broan-NuTone CV750 Central Vacuum

Recently my central vac system started making a louder than usual and laboured sound when in uise, enough so that I took note and inspected the canister and motor while running. The motor was trowing off blue sparks and looked like it could 'POP' at any moment. I will not risk using it until I know what the problem is and how to repair it. My assumption is the motor needs to be replaced. The system came with the resale house I bought 3 yrs ago but I do not know the age of the system itself.


... Vacuums

Low suction I have a Hoover central vacuum system. I've reset the fuse box, checked the fuses, all of the lines are clear and there are no holes for escaped air to travel out. The filter has been cleaned as well. The vac works well with high suction when hooked directly to the unit, however when using any of the indoor connections there is extremely low suction. The machine still turns on so I do not believe it is an electronic issue. I have troubleshooted the issue as best I could and would


... Hoover L2310 GUV Central System Vacuum

I have an aerus central vac. When I took it apart to try and clean ther motor the wiring came off. where can I get the info I need to rewire


Go to http://aerushome.com/ to locate an authorized shop near you.\015\012Their service department will have the info, but generally will require the machine to be brought in to ... Electrolux Centralux Vacuum

Wireing up central vac too braker box. - Vacuums


Http://www.geeksquad.fixya.com/ThreadView.aspx?prdid=0&thid=579196\015\012Generic problem for all ... Vacuums

I need a wiring diagram for a m&s central vac ntsp700a and can't find it anywhere.


... M&S Systems Vacuums

Can the two inlet pipes be connected to one line? The central vacuum I have is probably from 1993/4. It has one exhaust pipe and two inlet pipes. It was initially under my stairs. I would like to move it and have in fact moved it to the garage but am now fitting the pipes. I would like to join the two pipes that were previously going to the two inlets into one pipe. Can I do it? Also would I then join the wires? Would I put a plate on the other inlet? THANKS. It is a SMART president's choice vac


There is no real reason why not...As long as you have enough "****" then that should be fine, you will need to "Y" join and NOT a "****" joint. ... Vacuums

Low suction I have an Electrolux central vac that is approx. 11 yrs old. the suction is very low. this started about 1 week ago. I checked the hose and it is clear. I also went into the attic and checked the pipes(as far as I could see them) and they appeared to be intact.


1) Have you checked the filter? If it is clogged your suction will be low. Also, you could have a pipe loose where you can't see. Make sure that you can get a coin to go all the way through the hose. make sure the suction motor ( the unit ) is coming ... Electrolux Central Vacuum

What do I do when there is no suction. My central vac just stopped picking up and though I emptied the machine and replaced the filter there continues to be no suction.


1. If it's an older model, the hose is likely well worn and probably has leaks at each end where it attaches to the handle and connector at the other end. If this is the case, a new hose is needed.\015\0122. A blockage in the hose. To check t ... Electrolux Pu3650 Central System Vacuum

I have a model 1561 electrolux central vac..can i use a hose and accessories from a model 15448 model electrolux central vac to compliment my central vac unit


If the hose fits into the inlets, then there should be no problem. ... Electrolux Centralux Vacuum

Central vac (Hoover) always on!


\\thanks for the response... turns out I had two problems - both embarrasing I'm afraid...\015\012\015\0121) there was no auto mode on the switch - turns out that the OFF postion was auto.\015\012\015\0122) I had an undisovere ... Hoover L2310 GUV Central System Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0419 seconds