Having problems with your Broan-NuTone CV350 Central Vacuum ?

Switches will not turn off unit. model #cv450w


Answers :

If the switches on the hose will not turn off the vac you have a short in the wiring of the vac pipe system or a defective relay on the circuit board. Plug the vac in again without the hose and disconnect the thin low voltage wiring were it plugs into or screws onto the vac.
If the vac continues to run once disconnected from the low voltage circuit you have a defective relay in the vac itself. Some are circuit board mounted , others freestanding. To avoid a service call you can take the tank off the wall and take it to a pro shop or remove the top hosing if you are confident and check out the relay for a replacement part.
If the vac stops your issue is in the house. Has any painting been done or any inlets removed lately.. check that area first for a short at the inlet. Go back to any and all inlets and remove them one at a time checking the mounting screws and backing plates for loose wiring which is touching either the metal inner wall plate in the wall or a common screw . Test the vac as you go.
If this does not help, you will need to examine the wiring in the house , running along the pipe. Again if anything has been disturbed recently, near the vac, or near any piping that would be your first suspect area.
Post back to advise.
Repair Help & Product Troubleshooting for Broan-NuTone CV350 Central Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Switches will not turn off unit. model #cv450w


If the switches on the hose will not turn off the vac you have a short in the wiring of the vac pipe system or a defective relay on the circuit board. Plug the vac in again without the hose and disconnect the thin low voltage wiring were it plugs int ... Broan-NuTone CV350 Central Vacuum

Our dustbuster (dont' have model number with me-sorry) won't turn off when I pull back on the switch handle. I disassembled the unit and realize that the tab on the switch handle that pulls back on the internal switch handle to turn it off is not strong enough for its simple task. Does B&D have a proper replacement part?


If you can provide a model number, I can check availability of the switch and can either order it for you, or supply the B&D part number and you can order it from most local vacuum shops in your area or from Black & Decker direct online: ... Black & Decker 15.6 Volt DustBuster Vacuum

We recently bought a home with a 52" Hampton Bay Berlini Model 729 395 ceiling fan with a light that operates on a remote control. There is also a wall switch plate with two circular controls - one pushes and spins, the other turns with 4 clicks. We can not get the light or the fan to operate using either the switches or the remote. We have checked the circuit breaker. The manual that came with the unit - provided to us from the previous homeowner - really only describes how to install the uni


Nancy do you want to sell the Berlini fan if youstillo have it? ... Vacuums

My wife has a Revlon Rv051 curling iron .. has worked fine for several years but now it has stopped working. No response to pushing the ON switch (normally turns on a red LED). I've opened the unit and verified the integrity of the cord and swivel contact between the cord and the PC card. Unfortunately w/o any documentation of the PC card, I'm at a loss as to what to try next. My wife has had this unit for several years ... liked it well enough that she now has two more of the same model but


Is power making it to the switch? Sometimes the plug of the unit with pushbuttons has issues and fails. Maybe you can switch a plug from 1 of the other ones you have to test. ... Vacuums

Stops Immediately. We have a Beam Serenity model 2100 installed in the home and when the hose is inserted into the wall it turns on for a few seconds and then shuts off on it's own. Turning the handle's power switch off/on restarts the unit only to have it once again stop after a few more seconds. The canaster is clean. What could be causing this stopping issue? Thanks.


The Relay Control Board in the 2100 is bad. Replace and it should work just fine. ... Beam Industries 2900 Serenity Plus Central System Vacuum

Phantom model LC 51 00 of 5/98. Unit will no longer run. IE turn on switch and nothing happens.


... Fantom Vacums Lighting Canister Vacuum

When trying to use my Hayden Model 3600 central vac when trying to turn on the unit runs for 1 or 2 seconds and shuts off and continues to do so while switched on. I have thoroughly cleaned the filter and dirk canister but the intermittent running still occurs. Any suggestions?


... Hayden Industries SuperVac 3600 Central System Vacuum

Shark s3325 stopped working while steaming; thinking the unit had ran out of water I allowed unit to cool before refilling, however unit over flowed with only 700ml water added. When I plugged unit back into outlet it would not turn on (red light was not on) but I hear a click upon plugging in unit, when turning unit power button on and when turning on the handle switch. Please advise how to resolve this problem.


... Euro-Pro S3325 Handheld Steam Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?


... Vacuums

Unit has power from Plug to unit. Current flows all the way to switch and switch seems to be ok but unit will not turn on. Wife says it was cutting on and off when moving it around. Checked conntec


You either have a bad switch oir you have a short in the cord.plug it in and turn it on then move the cord around from top to bottom and see if it acts up..if not tap on the switch afew times and if it cuts out then the switch is bad.try to plug it i ... Vacuums

Hoover Upright Vacuum model U5470-900 - The On/Off switch on the handle does not properly engage the power switch deeper in the handle assembly. It appears to ride over the lower switch and doesn't engage it to operate it. If I play with it, I can get it to maybe turn on the vacuum, but, then the upper handle switch won't turn it off. Our current workaround is to use the power cord for on/off operation.


... Hoover Vacuums

I have a Electrolux canister model L-E (circa 1986). Won't turn on. I think the foot switch is broken inside. Was working fine - turned it off then would not turn on BUT foot switch sounded different, kinda hollow sound. Perhaps I'm reaching but wortha a shot? Mary


I have one of these LE models also. Yes, the on/off button is broken. I have had to replace it twice on mine. My local vacuum repair shop suggested NOT to use your foot to operate this switch, but just press it on or off with your fingers. That will ... Electrolux UltraLux 2000 Bagged Canister Vacuum

The unit does not start when I turn on the switch on the handle. The power nozzel runs, but the vacuum motor does not. The reset button is not popped, there is 110volts to the unit, and I tried flicking the switch inside the unit underneath the filter with no responce.


... Electrolux Centralux Vacuum

RE: Goldstar dehumidifier: Model #DH404EY6, S/N 602TAQP05412 My unit is ~4 yr. old, has worked w/o problems until now. It will no longer auto. turn on. When I manually turn it on, the motor turns on, and then immediately shuts off, and "01" appears on the LED screen for humidity level setpoint. Is this an error code, and what does it mean? Can the unit be repaired? Thanks, Wolfgang


... Vacuums

I have a 3 year old NuTone CV 353W central vac system and recently the switch on the hose handle does not turn the system on from any outlet in the house. I have to plug the hose into the outlet and then turn the unit on from the switch on the cannister. Any help would be greatly appreciated. Thanks


A great way to check if your switch in the hose is bad would be to turn the hose sideways in the inlet. If the unit turns on you most likely need a new switch. ... Broan-NuTone CV450 Central Bagged Central System Vacuum

Our vacuum will not stay running.. We have cleaned both filters several times since dyson told us there was a switch which turns the vacuum off if the filter in the ball was dirty, but we still need to keep pushing the switch several times to turn the unit back on while vacuuming.


... Dyson DC25 All Floors Bagless Upright Vacuum

My lux 7000 has a new bag but when i start to use it with the power unit or without the unit shut's it self off i can reset the lites or the motor if you will by clicking the on off switch 4or 5 times and i'm ready to go again untill you start to work and off it goes you can repeat the switch thing as long as u want, it just won't let u vacuum ,it turn's it self off .I blew it all out but found nothing in it. if u don't try to vacuum it will run as long as u want to listen to it. Can you


Have you replace the afterfilter? It may also cause this if rather dirty. It's located under the tool caddy/air diffuser on the back half of the machine.\015\012Try this: Disconnect hose, turn on vacuum. Does it continue running? If so, pl ... Electrolux Lux 7000 Bagged Canister Vacuum

My Kenmore progressive upright vacuum, model 11635923500 has a problem with the brush rotating. Sometimes the brush will not rotate until the unit in lowered way down, like the activate switch has rotated. Can I get inside the unit to check the switch, if so were do I look


... Kenmore Vacuums

Model # 5770 the brush motor runs and shuts down after a few seconds...Turn unit off and the brush again will run for a second or two...If I don't turn unit off brush will not start up..Could it be the printed board..the motor brushes..or the wiring that goes from the printed board to the main motor...Thank you


Seems like your unit goes into failsafe because it detects something wrong. Well you should check the brushes and replace them if they are worn out. Also check the wiring for shorts etc, becaue the unit maybe tripping due to an overload. The printed ... Bissell Vacuums

Over heating Light Comes on as soon as I try to turn the unit on. I have a Miele S558 Silver Moon vacuum that has only been used once and it shut off and will not come back on. The overheating light comes on as soon as I try to switch speeds on the handle or turn the unit on at the canister, and the vacuum will not run. Do you have any idea what the problem is?


... Miele s558 Silver Moon Vacuum

On-off switch My problem is finding a source for an on-off switch for an electrolux vacuum sweeper model 2100. I have replaced the broken toggle and now the sweeper turns on but only as long as the outside button is depressed. It appears that the on-off switch itself is broken as the switch does not ''hold'' when the toggle is activated. It seems to return to it's ''off'' setting as soon as the toggle is released. What ''holds'' the switch in its ''on'' position? Does it depend only on the on-


Hi Hugh. The 2100 has a rocker switch under neath the button. it is probably broken, or the button has a worn detent spring. If you would like, I could send you a switch kit with the rocker, button, and detent spring enclosed for around 20 dollars ... Vacuums

I have a model u6476 self propelled hoover.The switch will not turn or off all of the time.The plastic slide does not operate the switch but slides over it.The switch seems to work easy enough by hand.Cleaner was purchased 2-23-07 Any iseas?


If the rod isn't pushing the switch, then something inside the handle asm. broke and isn't holding the rod in place. More often then not, it is the switch, but could be the rod in this case. ... Vacuums

Eureka Vacuum Excalibur Model 6975A on/off switch won't turn off. Probably need new switch but can't figure out how to get cover off to get at switch


... Vacuums

I had the vacuum cleaner question about the canister and the wand/powerhead... the Kenmore Progressive Vacuum canister model 116.25812 and the canister not powering off without unplugging the vacuum. The solution I received that they both run on their own switch so it is normal makes sense. However, is there a power switch on the canister anywhere? The only way for the canister to be turned off is by unplugging it. Any ideas? One would think there would be a switch. I am new to fixya and hope


Hi. On some models, one switch controls all of the power. Your issue, which is no working switch is almost certainly a blown triac on the circuit boar ... Vacuums

Electrolux Epic 6500 SR ...no power to power nozzle. I think it is the switch in the handle because if I use my friend's hose/handle (same model), my power nozzle works fine when I turn on the switch. If you think it is the switch, can I get a part for it?


That's about the best one to narrow down a problem, however, there could also be a break in your hose wiring. Switches, hoses, and hose handle assemblies are all available at your local Aerus Electrolux store. Simply take your entire machine in so ... Vacuums
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy