Dyson DC04 i have a loose wire where the cable enters the cleaner how do i open the part where the on/off button is. A wire is loose probably but I cannot get to the interior to check its status. How can I take it apart? the plug is sealed but could it be a loose wire in there?

Answers :

You have to remove the yellow switch but to do this there is a small hole at the side of the switch nearest to the machine you have to push something in this which will push the clip that is holding the switch if you can do this there is a screw behind this that allows you to remove the switch
Repair Help & Product Troubleshooting for Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Dyson DC04 i have a loose wire where the cable enters the cleaner how do i open the part where the on/off button is. A wire is loose probably but I cannot get to the interior to check its status. How can I take it apart? the plug is sealed but could it be a loose wire in there?

You have to remove the yellow switch but to do this there is a small hole at the side of the switch nearest to the machine you have to push something in this which will push the clip that is holding the switch if you can do this there is a screw behi ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

We have a series e rainbow cleaner. my wife had been using it i turned off and turned the canister up sie down to get the serial number. it would not turn back on.we need a new hose and thats why i was looking for the serial num. it has a rocker switch and the motor will work on low but will not run on the suction side. i have checked the wiring harnesses out as best i could without taken it all apart. im wondering if it may be the switch. it started once and then stopped.

There is one way to verify if it is the switch.It's kind of dangerous though,but not too bad.You need an extra piece of wire,fairly thick.I would use 4 guage myself.Hold it with pliers,just in case it gets hot.Turn the switch on and hold the wire to ... Rainbow Vacuums

Green and yellow wire has broken loose want to know where it needs to go and could it affect the unit from not putting out steam

... EuroSteam Vacuums

The brush wouldn't work when the selector switch was in carpet mode. Took the power head apart and removed the motor. Everything o.k. in the power head. Checked and found that the neutural wire had pulled out of the connector, the connector was never crimped at the factory. What a day! Took 2 hours and a large pizza to get it done. Neutral wire was in the hose just below the handle. Reconnected the wire and crimped it, put everything back together. It works!!!!

Great. ... Kenmore Vacuums

NO POWER My Dyson DCO4 Absolute (purple&lime) won't' switch on. I've checked the plug fuse, wall socket and also filters and hoses on machine all seem fine so think the problem is with the on/off button (maybe loose wire or something) but how do i get to it, is there a special way to remove the green on/off button in order to check the connection? Thankyou in advance for the help i am sure you will be able to provide.

The problem is almost certainly a fatigue break in the flex. These usually happen where the flex enters the handle through the rubber sleeve near the on off switch. You will need to cut about four inches off the wire and reconnect it to the switch. ... Vacuums

Is there a diagram/picture to help me visualize how to put cleaner belt back in vacuum? I was taking base of vacuum apart so I could get rid of hair that were wrapped on the roller. The cleaner belt came to loose and I could not figure how to fix it back. the model is eureka upright bagless series 430

Hi,Sorry to hear your belt fell out. Not good if you've never replaced a belt before...Here is a website where you can read a detailed description of how to change a belt: http://www.ehow.com/how_8034505_eureka-belt-replacemen ... Eureka 431A Optima Bagless Upright Vacuum

** suction The best way to describe it is that when I was vacuuming I could see dust clouds at the front of the vacuum where the light is swirling around in the air. It was like it was blowing dust around instead of picking it up. I checked the tubing and found that it was clogged with some paper and hair ***** etc.... So I cleaned it out and tried it again and it still was not picking up properly. I had my husband take all the tubing apart to check for other clogging and there was none. When I

You have an airflow problem. You may still have a blocked intake or tube, also check the filter. The air is supposed to go in the bottom (of course) and I'm sure you k**w where it goes out. You probably can **te a reduction in exhaust. If this is ... Oreck XL Ultra Bagged Upright Vacuum


... Electrolux UltraLux 2000 Bagged Canister Vacuum

I have a Kenmore 116.36932 (upright-bagless vacuum) that the motor protector by-pass valve has opened. I've clean out the area between the agitator brush where the flexible extension hose starts. There was some blockage there. I checked the rest of the system (extenstion hose, back filter area, pipe area to canister and area to side filter. I took the 2 filters out and the by-pass valve is still open. Where else could there be a blockage that I can take apart to clean and put back together

... Vacuums

I have a miele s184 and on the same side where the hose connects to the bottom of the vacuum, the housing is very loose. It does not come apart , but it looks like it could. I cannot locate a screw or anything to tighten. Can you help.

... Miele S184 Powerhouse Bagged Upright Vacuum

My Sanitaire Commercial vacuum SC5815 A-2 does not turn on. It is quite new and seems to be "totally dead." Serial number: 0632005978 It is firmly plugged in, I have tried numerous electrical outlets, and I have tried the on-off switch numerous times. I wonder if there is a simple circuit breaker switch somewhere on the vacuum that I could switch without going to a repair shop? Or, I wonder if some latch is loose that shuts off the current, but I have checked the latches and they are clo

... Electrolux Sanitaire True HEPA Upright Commercial Vacuum Red EUKSC5713A

I am having problems with the roller on my Oreck DTX-1300. It turns on and off intermittantly while I'm vacuuming. I have completly taken it apart and cleaned and inspected the roller unit.(I am very much mechanically inclined) This has stumped me, I have checked the electrical from the vacuum to the floor unit, and everything else that I could think of. Question: what does the metal sensore plate on the bottom of the roller unit do?? Anything anybody can tell me, I would greatly appreciate. Cap

... Oreck DutchTech DTX1300A Bagged Canister Vacuum

My Electrolux Regency Series upright vacuum brush motor does not activate. Cleaned the brush and press reset to no avail. Opened handle switch assembly and checked each wire attached to all three switch settings. Tried disassembling brush assembly but could not pry open after removing all screws.

... Electrolux Vacuums

My Lasko fan is a year old type wta, TP120 volt AC 60 Hz 0.38 amps... the tower turns on but it wont blow any air out... what could be the problem i already checked and made sure all the wires are still connected.

... Vacuums

I cannot charge my two year old electrolux pronto. I purchased a brand new hand held vacuum for it, but even the new one does not charge. When I plug in the cord nothing happens. If I turn on either the long handle or the portable unit within the long unit, the blue charging light comes on for a few seconds, then out. This tells me that the circuit is intact without a broken wire somewhere. I took it all apart carefully and could see nothing broken or out of place. On re-constructing it, it

It must be the charging transformer. We have already ruled out the vacuum unit. Unfortunately the transformer is not a serviceable part, and will need to be replaced. ... Electrolux Pronto 2-In-1 Stick/Hand Vacuum - Cayenne

I have a Miele s251i vacuum that was working just fine until I umplugged it (while running) and re-plugged it in at a closer socket. When I replugged it, it started for a second and then stopped. Will not start now whether we use the on/off switch or not...suggestions? Would also like to know how to disassemble the unit so I could check out the wiring with a multitester..thanks

I just had exactly the same problem. Opened the vac, checked the circuit\012 next to the motor and it can be clearly seen that the Triac burned thru\012 the PCB. Will replace it and check again. Vac bought long ago, works \012extremely well. ... Miele Vacuums

Oreck Upright Hi Redev, I'm not sure what model I have (about 6 years old...upright, looks like the one in the picture). I changed the belt (which was torn) and then the next time I used it, it cut off on me. Now if won't turn on at all. (I turn the switch on and off and nothing happens as if it is not plugged in but it is!). I noticed at the top where the power cord enters the handle, it is all frayed. Could the electrical wires have detached? Anything you think I should check before taking it

The cord could be bad and will ahve to be replaced. It would have to have a problem inside the handle or down by the motor. ... Oreck XL2600 Vacuum

Have Fresh Aire 2.1 about 4 years was running great then went dead. I cant find where the fuse is and have unit apart. I plug in no fan dim display shows to errors. Unit was pretty dirty at the time. I need schematic and suggestions. Also need to knpw how to remove the honeycomb from the light unit to check for blown bulb. Seems brittle and I could break it with trying to pry with augur or sharp screwdiver object.

I'm sorry this may only be a partial help. But fuses are usually very close to the motor, OR where the switch is located. Pretty easy to find by testing but you have to be or so careful you dont electricute yourself. Now if your testing shows v ... Vacuums

This ge model aew10ajs1 keeps shuting off an doing its owen thing i checked for loose wires an the outlet is good the coil is a little dirty but not bad

The motor may be overheating due to a clogged filter. there are temperature switches in them that are safety switches in them to keep them from catching fire. ... GE Vacuums

No suction I cleaned and checked all hoses, sounds like something is stuck inside, like a sock, took machine apart as much as I could and couldn't find anything. Any suggestions?

Ok first thing to do is remove & clean the 2 piece premotor filter or purchase new.Now remove soleplate from bottom of machine to do this rotate the 3 plastic screws to unlock position. Lift sole plate off now remove any blockagers or ... Dyson DC07 All Floors Bagless Upright Cyclonic Vacuum

I had a loose wire in my Oreck XL motor. I took it

Lights are 12 volts.\015\012\015\012The motor has taps on it to pull 12 volts rather than 120 volts for the lights, uses the motor as a transformer.\015\012\015\012Should be black and white to the motor from the switch, believ ... Oreck XL Ultra Bagged Upright Vacuum

Loose wire ive got a loose wire inside my vax cyclonic 1700w and ive stripped it down but cant see anything and its still not working but it was working when i moved the wire from side to side. Please help

Sounds to me like you have a open wire. There is a break in the wire inside to the insulation and as you move it, it gains and loses connection. You can test it with a continuity tester as you move the wire or just replace it to see if that solves th ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Loose wire Been tugged causing loose wire at handle end of flex

Needs new cable 20.00 for replacement 0800 294 4692 ... Dyson DC14 Animal Bagless Upright Cyclonic Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?

... Vacuums

Wiring diagram for Model #11635922500 - KENMORE Upright vac I took the cover off of the vacuum to repair the power cord and must have pulled a wire out of its wire nut by the sweeper bar. If I had a diagram it would be no problem to replace. The bad has four short gray wires coming out of it. It is one of the gray wires that has come loose.

... Kenmore Vacuums
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar