Having problems with your Dyson DC07 Bagless Upright Cyclonic Vacuum ?

Motor cuts out after 5 mins on dyson vacuum

\015 All parts recently cleaned works fine for few minutesthen cuts out\015

Answers :

Hi Peter,

I'm sorry to hear about this. From what you've described, it sounds as if your machine may be overheating due to a blockage - the filter may also need a wash.

To locate and remove any blockages, please follow the steps shown in our online support guide:

http://www.dyson.com/support/help.asp?article=4&product=DC07-SY-HEPA_US

In normal use, the filter needs to be washed at least once every 3-6 months, as shown in the video below. Use cold water without detergent, and allow at least 12 hours for it to dry somewhere warm before replacing it in the machine.

This should resolve the issue, but for any further assistance or advice, please call us on 0800 298 0298 (UK), or 1-866-693-9766 (US).

Best wishes,

Jack
Dyson Online Customer Support
http://www.dyson.com

Repair Help & Product Troubleshooting for Dyson DC07 Bagless Upright Cyclonic Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Motor cuts out after 5 mins on dyson vacuum


Hi Peter,I'm sorry to hear about this. From what you've described, it sounds as if your machine may be overheating due to a blockage - the filter may also need a wash.To locate and remove any blockages, please follow the steps shown i ... Dyson DC07 Bagless Upright Cyclonic Vacuum

DYson DC07 not sucking properly when in upright mode. I have tried cleaning out pipes etc and even tried an old motor section I had in garage (replaced once under warranty as kept cutting out and they left old motor section here). Even the old motor section had same prob so this suggests its something in the rest of the vacuum cleaner (whats left after you have lifted off the green motor section and dust collection area if you see what I mean? Any advice weclome please.


Blocked filters ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Dyson DC07 My DC07 cuts out after 5 mins and I want to replace the thermal cutout. I have cleaned it thoroughly, including the cyclones but it still cuts out. How does the plastic moulding around the motor dismantle? I have started by removing the 4 torx screws but the upper grey housing does not want to detach and I am worried about breaking the plastic. Appreciate any advice.


Try this page: -http://www.fixya.com/support/t192124-overheating_dyson_dc07Regards Gualo ... Dyson DC07 Bagless Upright Cyclonic Vacuum

I have a nearly 9 year old Electrolux Excellio Z5228 vacuum cleaner. It has recently started cutting out during operation. I cleaned the micro filter (between bag & motor) via brush & hitting against wall & seems / looks quite clean. I washed the gore filter (output from motor to clean the exhaust air) as per instructions, then let to dry. It was very clogged but now very clean. The vacuum clearner still cuts out often. Even after a long rest (say overnight) it still won't start, then ano


... Electrolux Vacuums

Thermal senser on the side of the vacuum motor there is a little thermal senser that has rust all inside of it ,my ? is will that cause the motor to shut down ,could the rust in the senser causing it to cut off ,cause the vacuum runs well then cuts off


If it is going bad, it will cause the motor to shut down, replace it then you will know if that is the problem or a problem with the motor itself. ... Vacuums

Motor My vacuum cut out as I was using it. After some experimenting I found that the circuit reset had gone off. When I tried a second time while near the motor , there was a flash and again the motor shut off. At this time I am guessing that the motor is faulty. The central vacuuming is approximately 12 years old.


If it tripped the reset again, I would probably agree with you. Check out centralvacuum.com for another motor. They aren't the cheapest, but they have excellent support. Good Luck!! ... Easy Flo EF1400 Central System Vacuum

Dyson DC07 Vacume cleaner trips on thermal after 10 min motor not excesive hot resets after 15 min has been doing this for the last 3 mths. Could it be faulty thermal or motor overheat how can I check without changing motor


First, check both filters on that unit. the premotor filter on the side, and the hepa filter underneath the canister. if those filters are clean move through the suction channel and look for a clog or obstruction. also make sure the canister is clean ... Dyson DC07 All Floors Bagless Upright Cyclonic Vacuum

Why does my dyson dc04 work for about 5 mins then cut out the wire on my dyson 04 needs replacin but i cant get the casing off. My DC04 cuts out after abou 5 minutes use. I think there may be a thermal cut-out somewhere?


Thermal cut out in coils of motor,you have not been keeping filers clea,I THINK.\015\012motor is avaliable ... Vacuums

Kenmore canister vacuum model 116-25512506. It has a 2 stage switch on the handle, the vacuum motor will not work, the carpet beater attachment does work, the vacuum motor will not cut on at all with either stage, 1st stage is vac only, 2nd is vac a carpet attachment. Carpet attachment will work, vac does not.


Try to find the reset button. It should be somwhere near the bottom area. It looks like a red dot that you can push inward. If you can press and hold the reset button, it will restart your suction and solve your problem. ... Vacuums

We have a Kenmore Progressive Model 116 Upright bagged vacuum with Hepa filter. It's at least a couple years old. For quite some time now when ever we use the vacuum the vacuum motor will shut off nafter about 5 min. of use. We then need to let it sit for awhile and then we can run it again for another 5 min. The bag has been change. Any one have any ideas how to fix this?


I suspect that you have a restriction. The motor sounds like the thermal break is stopping the motor before damage, due to heat.\012You must witness that the entire suction and discharge side are clear. This is not always very easy, but necessa ... Kenmore 34612 Bagged Upright Vacuum

Dyson vacuum cuts off


Hi this sound like a familiar problem of the motor o/heating due to lack of ventilation ? check the filters ok? remove the cover concealing the roller brush/beater and check for clogging at the underneath and housing clear it out properly ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Where do you hook the clear hose that is in the compartment with the motor ? Second where the vacuum hose connects to the bag it keeps cutting in and out of power. I replaced the female cord to motor and still cuts out."no suction "


Would you care to tell us the make and model of the vacuum you're asking about? ... Vacuums

I have a dyson animal dc17 vacuum and it totally died. Now I can't figure out which wires go where when I install my new motor. (motor #: 160906G) Do you happen to know where the various color wires go or a place I can see a diagram of the motor with wires attached? I should have taken a photo of it before tearing out the old motor. I don't know where to connect the three coming out from the upright portion of the machine and the red seems to go to a switch (?) and there is a black (connected t


... Vacuums

After vacuuming with my Dyson animal DC 17 I placed the vacuum in a upright position and the vacuum cuts completely off. Also the wand no longer has suction....


Hi John,I'm sorry to hear you're having difficulties with your DC17. This issue sounds unusual, and we'd appreciate the opportunity to provide further assistance. Please call us free on 1-866-693-9766 - or if you'd prefer, email your details ... Dyson DC17 Animal Bagless Upright Cyclonic Vacuum

Simplicity vacuum My vacuum just cut off and now it wont start. I pressed there restart button but nothing happens I have 2 fairly old Industrial hitachi dry vacuum in my workshop both 110v and both wont start. Both i was told were manufactured in Italy and both have a manual and auto switch. It has a black top, takes an orange paper filter inside and its bin is dark blue. Sorry i've forgotton the model number. I've inspected the wiring but it's fine, could it be the motor and how do i gain acc


Just take it in to your vacuum store. ... Hoover U5753-900 WindTunnel Bagless Upright Vacuum

Have a rainbow e series with 2 speed motor replaced motor with another now after 5 minutes on the vacuum the motor cuts off intermitently like a power surge. all the connections and wires have continuity any ideas???


... Vacuums

Electrolux 2 in 1 Ergorapido stick Vacuum. Motor runs then cuts out after 3 - 4 seconds. Sometimes it will run properly for 10 minutes so batteries are good. Why does it cut our usually?


If the hand held is working correctly (By itself) try pulling up a little bit on the 4 metal connection tabs on the wand. The connection tabs were not making a proper connection on my unit. ... Electrolux Pronto 2-In-1 Stick/Hand Vacuum - Cayenne

Motorized brush bar not turning on Dyson Vacuum


Apparent common failure is that either the thin yellow and or blue motor drive wires that run from the LH side of the vacuum where the "control board" is located down into the hinge / ball area become stretched and then fray and eventually break. Ha ... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

Dyson dc14 cuts off after @10 mins. checked for clogs, but none. but, recently cleaned alot off the beater bar


Check the filters. There is a video tutorial here: Looking after your Dyson ... Dyson DC14 Animal Bagless Upright Cyclonic Vacuum

Dyson dc05 motor cuts out


Hi,\015\012\015\012Check for either voltage to switch or if your not happy or compettant working on live mains.\015\012Switch meter to ohms ensure vacuum is unpluged from mains follow live wire (brown) from plug to exit point on the ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Motor loud I have a dyson dc17..recently when i turned it on and pulled the handle down to vacuum the motor was very loud..put the handle in the upright position it is quiet.any suggestions?


When you put the handle down it turns on the brush roll. you may need to clean the brush roll or replce it if the bearings are bad.also clutch and 2 belts are started when putting handle down for brush operation. ... Dyson DC17 Animal Bagless Upright Cyclonic Vacuum

Why does my dyson dc04 work for about 5 mins then cut out the wire on my dyson 04 needs replacin but i cant get the casing off.


This post may be of assistance: http://www.fixya.com/support/t2842769-fix_new_power_cable_dyson_dc07\015\012\015\012Hope it helps ... Dyson DCO7 Animal Bagless Upright Cyclonic Vacuum

I'm trying to figure out which dyson vacuum is better, the DC14 or DC17. from what i read, the DC17 is the newer model of the DC14, the DC17 added an extra motor for the brush, but from the dyson site, the DC17 has less suction power. it went from 250AW (dc14) to 220AW (dc17). is that a significant difference that i should be worried about?


Hi,DC17 is much better than DC14. I always believe User's review are much better than what Features Company usually Displays.Read :-http://www.epinions.com/review/Dyson_DC17_Animal_Vacuum/content_404790546052 ... Vacuums

I have a dyson canniter stow away vacuum. i've had it for 2 years and it just started having a problem. when i turn it on the motor starts just fine but the vacuum head does not turn on. Yet when i push it forward it trys to start and turns on for a second and turn off - almost like the connector isn't connecting the hose to the head very well anymore.


Hi, After reading you're problem, the symptom's are just like you said. Its just a matter of checking the connections. The connection where it plugs into the head it self. When you push forward the forward motion and down pressure makes ... Dyson "Stowaway" Canister Vacuum Vacuum

HOW DO I CHANGE THE MOTOR ON A DYSON UPRIGHT - Dyson DC07 Bagless Upright Cyclonic Vacuum


Go to www.dysonmedic.com then scroll to the bottom of the page and click on DC07 motor replacement. You will find very detailed illustrated guidance. ... Dyson DC07 Bagless Upright Cyclonic Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.1067 seconds