Having problems with your Dyson DC18 Allergy Bagless Upright Vacuum ?

Handle sucksion no longer working. When we go to use the extender to vacuum the handle does not have air flow.

Answers :

Repair Help & Product Troubleshooting for Dyson DC18 Allergy Bagless Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Handle sucksion no longer working. When we go to use the extender to vacuum the handle does not have air flow.

... Dyson DC18 Allergy Bagless Upright Vacuum

U5468-900 handle on/off switch no longer works. Switch on main body works fine. Seems like handle assembly has worn out. Can I get a replacement?

... Hoover U5468-900 WindTunnel Bagged Upright Vacuum

We have the Kenmore progressive direct drive (bagless) and have had it for about 3 years. We have taken good care of it, and paid quite a bit for it hoping that it would last for a good long time. It has started making a noise that seems to be an overflow air type of noise coming out of a bottom air outlet opening for when the air flow is blocked. We have looked into clogs, changed filters, and the whole works, to no avail! Quite Frustrating since I love this purple vacuum! The machine started

There has to be a clog or block somewhere - if the motor works, it should work did you try a wire coat hanger to go up in further where you cannot see?Bets regardsCk ... Kenmore Progressive Bagless Upright with Inteli-Clean SystemVacuum

Hoover SteamVac Plus 1200 upright hot water extractor Water/carpet cleaner applying o.k. Suction on the "floor" does not work. Suction on the hand tool works somewhat, but water is not collecting in the bucket. There is suction coming from the floor but water is not going into the bucket. It does not appear to be clogged because I can feel with my hand that air is flowing from the floor. The water is not being sucked into the bucket.

... Hoover Vacuums

I have an Aerus Guardian canister vacuum with a clogged hose. The tiny stuffed animal toy is lodged right below where the swivel handle meets the hose. Switching the air flow does not dislodge it. I would like to remove the handle from the hose. Any suggestions?

Consider this. If your vacuum is still under warranty, removing the hose will void the warranty on the hose. I strongly recommend calling an authorized dealer/consultant.\012Although it may seem to be fairly simple to remove the handle, there ... Electrolux Guardian Bagged Canister Vacuum

My Lg Canister vacuum keeps beeping and shutting down even after filters have been cleaned or replaced also air flow is low causing the brush attactment not to work properly

... Vacuums

Have a quite new easyvac. Worked great the first time. Emptied the cannister, put it back together, and now have no suction. Only hot air flowing out from near the bottom of the clear cannister.

Check the clear canister. You may not have:\015\012\015\012gotten it seated correctly\015\012there is dirt or some other object preventing a good seal\015\012you lost or dislodged ... Bissell Vacuums

We have a Wertheim 3180 vaccum that the suction is no longer working. The air is blowing out but no suction coming in.

... Vacuums

Shark s3325 stopped working while steaming; thinking the unit had ran out of water I allowed unit to cool before refilling, however unit over flowed with only 700ml water added. When I plugged unit back into outlet it would not turn on (red light was not on) but I hear a click upon plugging in unit, when turning unit power button on and when turning on the handle switch. Please advise how to resolve this problem.

... Euro-Pro S3325 Handheld Steam Vacuum

Poor flow takes two cycles to brew one cup. Heater working etc. Something stuck inside inner tube? Sucking air somewhere? can it be dis assembled?

This problem is usually caused by calcium carbonate deposits from hard water collecting in the thermal pump mechanism. The fix is to make a 1/2 pot mixture of white vinegar and cold water (about 50:50) and run through several times. Let cool off each ... Vacuums

My vaccum has a 3 position handle. This no longer works, so I have to pick up vacuum to move it. Makes it hard to vacuum scatter rugs. It does not lock into place

What is the brand and model of the vaccum? the description i see says Hoover U6311930. When I check the info for this model it gives me maytag vaccum cleaner. ... Hoover U6311-930 Power Drive Bagged Upright Vacuum

While vacuuming air started flowing out of a hole on the right side of the machine directly below the canister that catches dirt. And the engine became hot to the touch. We have only had the unit for 3 months and no one in Austin Tx works on this model so any help would be appreciated.

... Shark Navigator Bagless Upright Vacuum

Suction Problem I took my unit to my work and used it, when I returned home it wouldn't suck up anything. I took the recovery take out and it has inward suction. Shouldn't that be outward, so it goes into the tank? It also blows out of the bottom by the brushes. I check the filter in the bottom and that is fine. Is it possible that it is somehow reversed the direction of the air flow (rotor running backwards)? I am perplexed. What am I missing?

There is a stand pipe seal where the bucket sits on, and if it isn't there or out of place could cause a suction problem like you said yours is doing. In the picture it is #10. The motor seal may have gone bad and is leaking # 15.\015\012 ... Hoover F7220900 SteamVac V2 Upright Vacuum

We have a Dyson DC28. The brush no longer turns while vacumming the carpets. Also, the lights on the handle to adjust for different heights do not work. Can you help. I see of no way to get to the belt but I don't think it is broken.

Hi there,I'm sorry to hear you're having difficulties with your DC28. It's probably best if you get in touch with us directly so we can resolve this issue for you as quickly as possible. If a repair is necessary, this should be covered by our ... Dyson DC28 Animal Bagless Upright Vacuum

The problem has been getting worse. It works, then cuts off. Then works and cuts off. Making sure the canister is not full. Time b/w it working is getting longer and longer. Almost seems this time when I change the outlet it is plugged into it works. But then shuts off quicker than it was doing before. I'm getting very frustrated.

We had exactly the same problem with our Animal. After the motor was replaced under warranty a different engineer came out and diagnosed it as the cyclone chamber itself being clogged.(the bit with the purple cylinders on it). This is completely unse ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Bisell Healthy home vacuum stopped working. The troubleshooting guide said there could be a problem in the connection at the handle. None of the phillips screwdrivers we have seem to work in removing the screw that holds the handle to the vacuum. What size phillips screw driver should we be using? If the screw is stripped, how can we get it out to replace it since it is not easily accessible in the handle?

You should use a p2 size phillips. there is only one screw right in the center that holds the handle assy on. frequently that screw backs out and allows the handle to slide back and loose connection. make sure the handle is tightly pressed in and the ... Vacuums

My infinity vacuum has an air flow restriction/no suction

... Vacuums

Brush not working when the handle is reclined

Sonds like you have a problem with the self propel switch in the handle. Since you didn't provide a specific model number, I can only give you generic information on what might be the problem.. Here is a link for a hoover upright model ( may or may n ... Hoover Vacuums

I have a Kenmore Central Vacuum Type K Model s107. The system will not work with the short handle, therefore I can not use the adapter brush ect. It will work when it is connected to the long handled main attacment. Any suggestions on how to fix this problem?

... Kenmore Vacuums

Hoover U6637-960 the self propel is not not working. When lowering the handle it acts like it would like to work but the roller will not turn. appears to be something to do with the self propel part of the handle . took the screws aout but can not get it apart. Is there another belt of something in there?

This vac has 2 belts. If both self propel and roller not spinning then most likely it is the wide flat belt broken or off. 4 screws on the bottom should gain you access to the belt area. another issue for this model series is a worn pulley on the rol ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Roomba Discovery My Roomba Discovery seems to work fine, mechanically, but it no longer seems to collect any dust. (The collection bin remains empty after the Roomba has circulated around the floor for quite a while). The brush has been replaced and spins normally. Does anyone have an idea why this machine's vacuum function no longer seems to work? I would appreciate any feedback. Jeremy

Did you replace the filter? when you remove the dust bin there is a small filter that needs to be cleaned, or replaced. You can buy a maintenance kit that replaces the brushes and filters as well, its good to replace them all regularly ... Roomba Robotic Floor Bagless Vacuum

The handle for my Eureka 5993 AVZ was getting very hot when used. Finally, the wires around the switch melted and now the vacuum will not work. What is wrong? Is the switch bad? The wires only melted in the immediate vicinity of the three-prong switch. Nothing else appears to be wrong; the vacuum worked fine when it was running - except for the handle getting hot. Thank you!

Try cleaning all...\015\012if have sam paoblem need replaced main motor.... ... Eureka 5893AVZ Bagless Upright Cyclonic Vacuum

Bissell Pro-Heat 7901-1 no cleaning solution is pumped out. The flow indicator is spinning and the belt is spinning the beater bar. Have cleaned the flow indicator, checked vavles in the solution tank and water tank and they are working properly. Also checked the trigger to make sure it works okay. Any ideas?? Moody Fan

Bissell Pro Heat shampooer - Fill the soap dispenser with extremely hot water and shampoo with only water for a few minutes. There is often dried soap in the lines. Make sure that all filters are clean. Press the soap container and the water conta ... Bissell 7901-1 ProHeat Scotchgard Upright Wet/Dry Vacuum

The mechanical off/on in the handle is not working with the electrical on/off switch upon removal of the handle you can cut the machine off by hand but after ensuring the the handle is re-placed in the proper position the machine will not turn off so what new handle or is the rocker switch has worn is now to hard for the mechanical switch to operated

Hi there it's SmartAlec from NelsonVacuums.com.au here. You are spot on in your diagnosis however i have fixed heaps of these and i have found no way to tell wether its the ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Nothing inn the canister after using,suctione working,bottom roller working,no air leaks from hoses.Also when running awhile it shuts off by itself,have to wait awhile to use again

I'm not sure what vacuum you have, but that sounds like a blockage to me. Thermal shut off kicks in, shutting the motor down, to prevent damage from overheating. After waiting like 1 hour it probably comes back on. Make sure hose, filters, bag (if an ... Vacuums