My dyson dc 25 just keeps blowing the c breaker when i switch it on


... Dyson DC25 All Floors Bagless Upright Vacuum

Hoover EmPower 4600 keeps blowing circuit breaker. The number of outlets in the house that will allow me to run the vacuum is dropping quickly. It is a 4 year old house and all the circuit breakers are 20 amps. The vacuum only has a 12 amp motor. I am at a loss to solve this problem.


Take it to a friends house and plug it in if it does the same thing then the problem is in the vacuum cleaner.check your cord and see if there are anny cuts in it.you can open the breaker box then plug in the vacuum and watch the breaker box.you migh ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Our vacuum will not stay running.. We have cleaned both filters several times since dyson told us there was a switch which turns the vacuum off if the filter in the ball was dirty, but we still need to keep pushing the switch several times to turn the unit back on while vacuuming.


... Dyson DC25 All Floors Bagless Upright Vacuum

Dyson DC 25 Filter located in ball keeps blowing off when motor is started.


... Vacuums

The F1 fuse on the PCB in my Dyson upright keeps blowing.


... Dyson Ball DC24 Bagless Upright Vacuum

The on/off switch won't depress and keep the vacumn on I have a Dyson dc14 animal upright


Hi there,Sorry to hear you're having a problem with your DC14. So we can assist you, please call us free, on 08002980298 (UK), or 1866MYDYSON (US). We can run through some checks over the phone, and arrange service if necessary. ... Dyson DC14 Animal Bagless Upright Cyclonic Vacuum

My Dyson DC25 keeps blowing off the filter within the ball. It then stops the ball from rotating freely. Will a replacement filter solve the problem?


I just started having the same problem. Did you figure out yet? ... Dyson DC25 All Floors Bagless Upright Vacuum

My Dyson DC25 keeps blowing off the filter within the ball. It then stops the ball from rotating freely. Will a replacement filter solve the problem? Sear has no clue they "THINK" it's the filter


Ive just been onto Dyson and they have sent me a new filter . i mentioned 2 other parts that were broken and they're sending those too . All free of charge , RESULT !!! ... Dyson DC25 All Floors Bagless Upright Vacuum

Dyson Vacuum won't switch on - breakers in panel all OK. Tried multiple plug in - no help.


Hi .\015\012\015\012Could be the on off switch faulty. Or a internal break in the mains lead this usually occurs where lead enters machine.\015\012Try wiggling the mains lead & see if it starts & stops.\015\012\0 ... Dyson DC14 Full Access Bagless Upright Cyclonic Vacuum

I've been vacuuming and my Dyson Animal (serial #112USE1564) keeps stopping. I checked for blockage, and none, should I have it looked at for a bad thermal cut-off switch? Please e-mail an answer to my e-mail address([email protected])ASAP!!


Hi there, I have experienced this myself and found it was the thermal cut off switch. Usual symptoms are running for a few minutes and then suddenly stopping, leave for a while and turn back on. I am sorry I cannot email to your personal addresas as ... Dyson DC07 Bagless Upright Cyclonic Vacuum

My Dyson DC 15 makes a horrible noise when switched to do carpets - sounds like gravel in the motor - and then comes the burning smell. Nothing keeping the brushes from moving, and I think they are. I am concerned that it is a belt or the motor. How do I know?


... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

Hi i have a dyson which appears to be blowing out instead of sucking in air....is there a switch i need to adjust?


This could be the  cyclone in the bin if it upside down or missing this can make the unit blow outwards it is common for this to happen i have known people to throw it away when they empty the bin if your not sure the google a picture of your un ... Dyson DC08 Cylinder Bagless Canister Cyclonic Vacuum

My dyson keeps blowing the fuse, what can it be? as soon as you turn it on it stops? thank you


... Dyson DC14 Animal Bagless Upright Cyclonic Vacuum

My dyson animal works for a while then shuts off...i guess it's getting hot and automatically turning off to keep damage from occuring. i have cleaned the filter and all the collection basket, but am still ahving problems. it was just services a year ago and a new switch installed. please help!!!


The belt that drives the beater bar may be broken or stretched, causing the motor to turn more freely, therefore causing the motor to rev beyond it's design.Jim ... Vacuums

Our dyson ball vacuum keeps blowing air out of a valve at the top of the collection canister causing it to lose sucction. why?


That unit redirects the suction to that valve to protect the motor. check both of your filters and also check for a clog. make sure to clean the inside of the canister as thouroughly as possible. ... Vacuums

My dyson dc10 keeps blowing off filter within the ball


... Vacuums

Dyson DC35 has a faulty handle switch


... Dyson Dc35 Digital Slim Animal Cordless Vacuum Cleaner

Dyson won't keep running


THAT IS THE PROBLEM U NEED TO FIX OR REPLACE THE SWITCH ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Dyson DC35 has a faulty handle switch


... Dyson Dc35 Digital Slim Animal Cordless Vacuum Cleaner

VACCUM KEEPS SWITCHING OFF /NOT SUCKING


First thing would be to check the bag as it may be full. If the bag is full the machine will overheat quickly. Also check the internal filter in the bag cavity to make sure that isn't dirty.\015\012\015\012Next, check there's no blockage ... Vacuums

Dyson DC25 filter within ball keeps dislodging


... Dyson DC25 All Floors Bagless Upright Vacuum

HOW DO I REPLACE THE THERMAL SWITCH ON MY DYSON DC07?


Here is a video how to take the motor out the thermal switch is fixed to motor ... Dyson DC07 Bagless Upright Cyclonic Vacuum

I have a Dyson slim DC18 all floors, the power switch is bad it won't stay latched I would like to get 2 of the switches. Dyson 18 s/n 334-US- A 26163 Nelson LePla 5495 S.Fordney RD Hemlock MI 48626


You can order the switch from the following sites. According to the first site, the DC17 and DC18 switches have the same part number, so I'd use the second site. It costs less. I didn't check the shipping costs, though.\015\012 ... Dyson DC18 all floors Bagless Upright Cyclonic Vacuum

Dyson 014 keeps losing suction


... Dyson DC14 All floors Bagless Upright Cyclonic Vacuum

We have a dyson dc 07 animal the machine was working fine then switched off after returning to the machine minutes later it wouldnt switch on, i removed on off switch cover and used a short piece of wire across the brown wires flicked the wall switch and it worked, aha i thought faulty switch aquired a new one to no avail and now even the short piece of wire trick doesnt work, has the motor died do you think, it wasnt over heating or making strange noises prior to refusing to work


It could be the motor. I'm having to replace the brushes on my DC 05. It appears that you can only get brushes for the YDK motors in the DYSON, not the Panasonic motor. Which might be saying something about the YDK motors. What happens is that the ca ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0447 seconds