Having problems with your Dyson Vacuums ?

Dyson cuts out after a short time then restarts after some time

Answers :

Repair Help & Product Troubleshooting for Dyson Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Dyson cuts out after a short time then restarts after some time

... Dyson Vacuums

Vacuum shots down after a short time, restarts but runs only a short time

Yes that unit has 2 sensors 1 on the motor and 1 on the relay board 1 of them is bad which is making the vacuum shut its like a heat sensors its malfuctioning it shuts the unit down ... Broan-NuTone VX550 Bagged Central System Vacuum

I have a Dyson upright vacuum cleaner makes a helluva racket whilst in use. Called up Dyson and they told me to flip the floor/carpet knob 10 times back and forth. That did the trick for a short while and it started again. Continue attempts useing that technique does not work. I think in spite of the big bragging I see on the TV this guy braying about how superior his product is it is a piece of junk. I should have bought a Eureka or something, at least it would have been less expensive. I

Hi there,I'm sorry to hear you're having difficulties with your DC07. Your cleaner's brush control system is designed to make a ratcheting sound to warn you if the brushbar is jammed. Since you haven't been able to resolve your issue with ... Dyson DC07 Bagless Upright Cyclonic Vacuum

My Dyson DC04 Keeps cutting out after a period of time

Check the bottom left hand corner, there should be a yellow button, that could be open, when it's open it, it won't **** ... Vacuums

New Dyson DC24 ball vac 2nd time using brush stopped rotating when caught on short rug fringe/ no mat'l caught

Hi there,Your DC24 is equipped with a sensor which shuts off the brush bar if something jams it. You can reset the machine by following the steps shown in the video below. You may also want to refer to our online Support guide: ... Dyson Ball DC24 Bagless Upright Vacuum

Dyson dc23 canister rug attachment loses power after about 5 seconds, push red button and restarts for less time. After 3 or 4 trys of it working for seconds it just doesn't turn on again. Reall

Hi Elizabeth, it's Jack at Dyson.I'm glad to hear you've been in touch already and we're able to resolve the issue under your machine's 5-year guarantee. In most cases, the issue you've described will be caused by something jamming th ... Dyson DC11 All Floors Bagless Canister Cyclonic Vacuum

Engine cuts out after running for a short period of time

... Clymer Evinrude/Johnson 2-70 HP Two-Stroke Outboards Includes Jet Dri

Their is a short cirut.My dyson keeps cutting out,is it a loose connecction or the fuse in the plug.How easy will it be to repair.?

Clean and wash all of the filters as this can cause the motor to run hot triping th thermal fuse. aslo dirt cannister pulled apart and rinsed through till clean helps. ... Vacuums

Why does my MCE3011 cut out after a few minutes-it restarts after being switched off and left for a short while?

... Panasonic MC-V7380 Vacuum

Aquavac runs for short time then cuts out blowing the RCD . Have rewired mains cable thinking a broken or loose wire... still same problem. Have also noticed that a lot of sparks etc coming from the motor brushes. Vac approx 10-15yrs old.Aquavac is model 6310B

... Vacuums

I have a Z5930 vacuum and i want to trace an electrical fault. I need to disassemble it to get to the electrical connections and it is quite a tricky one to get in side. The machine will run and then cut out after a short time. It will then re-start in about 2-3 minutes and run normally again and so on. I was not able to give you the exact model but it is Ultra Filtration Oxygen line

... Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum

I have two dyson dc07 and they work but cut after a short while

After they sit for a while do they work again? This is the same thing mine is doing and I am trying to find out if there is a thermostat or switch that can be replaced. ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Vacuum shuts down after a short time and needs to cool off before being restarted.

Trash it! ... Dirt Devil Reaction Twin Cyclone Upright Vacuum

My dyson dc 16 hand held vacume stops & starts while in use, each time you pull the trigger it will start again but then stops after a short while untill i pull the trigger again.

Cutting out can be due to a few things , motor overheating due to dirty filter, Faulty mains cable or plug..sealed type also..Faulty Switch/trigger.May need to seek pro help to fix. ... Vacuums

My handheld dyson is not working - initially it was cutting out after only a few mins then seconds now it won't work at all despite showing green light ??

Hi there, it's Jack at Dyson.I'm sorry to hear your DC31 Animal is only working intermittently. When fully charged, this machine should have a maximum runtime of 10 minutes, or 6 minutes on the maximum power setting.There are several ... Dyson DC31 Animal Bagless Handheld Cyclonic Vacuum

Why does my dyson dc04 work for about 5 mins then cut out the wire on my dyson 04 needs replacin but i cant get the casing off. My DC04 cuts out after abou 5 minutes use. I think there may be a thermal cut-out somewhere?

Thermal cut out in coils of motor,you have not been keeping filers clea,I THINK.\015\012motor is avaliable ... Vacuums

I have an animal dyson. The front nose dives into the carpet when moving the dyson in the forward motion, fine when pulling back. A huge amount of effort is required to move it forward. Took it to a technician and he said he could find nothing wrong. He had only short nap carpet for test. Works fine on short nap, if the carpet nap has any lenght to it like shag, the dyson severly nose dives. It's like the nose is sucked into the carpet. This problem just occured after the wife used the ho

... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Dyson vacuum cuts off

Hi this sound like a familiar problem of the motor o/heating due to lack of ventilation ? check the filters ok? remove the cover concealing the roller brush/beater and check for clogging at the underneath and housing clear it out properly ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Dyson DC35 cuts out after 10 seconds or so, and only starts when it feels like it

... Dyson DC35 Digitial Slim Multi floor cordless vacuum cleaner

The problem has been getting worse. It works, then cuts off. Then works and cuts off. Making sure the canister is not full. Time b/w it working is getting longer and longer. Almost seems this time when I change the outlet it is plugged into it works. But then shuts off quicker than it was doing before. I'm getting very frustrated.

We had exactly the same problem with our Animal. After the motor was replaced under warranty a different engineer came out and diagnosed it as the cyclone chamber itself being clogged.(the bit with the purple cylinders on it). This is completely unse ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Vacuum either stops for no reason and can't be restarted without unplugging and waiting 1/2 hour to restart, or it simply will not turn on at all. The red light comes on when the "On" button is pressed. I took it back today for the 4th time in a month to where it was purchased. They called later and said it was running fine and they could not detect a problem. The last three times they have (1) replaced the roller brush, (2) "unclogged" the vacuum, and (3) "adjusted" the belt.

This sounds like it might be an overheating problem. \015\012\015\012Some vacuum motors are fitted with thermal cut out fuses or thermistors which cut off the flow of electricity to the motor when the temperature gets to high. It is possi ... Lindhaus Activa 30-38 Bagged Upright Vacuum

Roomba 4000 runs ok 4 short time then stops upon hitting obstacl

The wheels are off balence. ... Roomba Robotic Floor Bagless Vacuum

My Miele Vacuum s5980 power cuts in and out?

Go to support on the Miele website. Enter your model number and search trouble shooting for your solution. murf427 ... Miele S 5980 + SEB 217 Bagged Canister Vacuum

Run cut off -run cut off every ten minutes - Dyson Vacuums

The TOC(thermal overload cutout) on the motor is getting too hot - thats why it keeps shutting off and starting again once its cooled, so make sure your filters are clean and they are no blockages in the hose or the brushbar compartment or any where ... Dyson Vacuums

Using my Proheat bissel 7901 I wil hear a popping sound than suction will stop. The machine can run for long periods of time or short time before it happens, what could it be?

Clog in the suction side somewhere the pop is the safety as to not burn up the motor. ... Bissell 7901-1 ProHeat Scotchgard Upright Wet/Dry Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy