Having problems with your Dyson Vacuums ?

Can i access the thermal switch on a dyson dc19 myself

\015 Just want to know if i can access the motor and thermal switch myself\015

Answers :

Repair Help & Product Troubleshooting for Dyson Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Can i access the thermal switch on a dyson dc19 myself

... Dyson Vacuums

My Dyson DC 24's beater bar switch didn't actuate and the beater bar didn't turn. When I brought it to a certified serviceman he told me that a wire interferred with the switch and all he had to do was move the wire out of the way of the switch. At the time the machine was under warrantee and it didn't cost me anything. Now however, the machine is out of warrantee and the problem has returned. Does anyone know how to access the switch and move the wire out of the way?

Hi- I had the same experience but it turns out there's a small trip switch if you've taken the brush out to clean it, it needs to be reactivated by pressing the small red button to the right of the brush... took me a year to figure this out! Been mea ... Dyson Ball DC24 Bagless Upright Vacuum


Here is a video how to take the motor out the thermal switch is fixed to motor ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Dyson DC04 vac.cleaner how do I access the on/off switch casing to repair a broken wire

... Vacuums

I've been vacuuming and my Dyson Animal (serial #112USE1564) keeps stopping. I checked for blockage, and none, should I have it looked at for a bad thermal cut-off switch? Please e-mail an answer to my e-mail address([email protected])ASAP!!

Hi there, I have experienced this myself and found it was the thermal cut off switch. Usual symptoms are running for a few minutes and then suddenly stopping, leave for a while and turn back on. I am sorry I cannot email to your personal addresas as ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Sears 116.31913 Lower units, vacuum motor and agitator power head do not have power/115v to them and won't run. I'm trying to take the handle apart to access the on off switch. I've taken all observable screws out and cannot separate the handle and section immediatly below the handle to access the on/off switch, to trouble shoot. Any tips for separating the plactic pieces enclosing the on/off switch?

... Kenmore 31913 Progressive Direct Drive Bagged Upright Vacuum

Need Access To ON/OFF switch

It is almost vertainly a broken wire in the cable. I have had this problem before. If you have a five year guarantee Dyson will fit a new cable free of charge. Just call them. Otherwise you they do a refurb at your house for £60! ... Dyson DC07 All Floors Bagless Upright Cyclonic Vacuum

I have a Dyson slim DC18 all floors, the power switch is bad it won't stay latched I would like to get 2 of the switches. Dyson 18 s/n 334-US- A 26163 Nelson LePla 5495 S.Fordney RD Hemlock MI 48626

You can order the switch from the following sites. According to the first site, the DC17 and DC18 switches have the same part number, so I'd use the second site. It costs less. I didn't check the shipping costs, though.\015\012 ... Dyson DC18 all floors Bagless Upright Cyclonic Vacuum

We have a dyson dc 07 animal the machine was working fine then switched off after returning to the machine minutes later it wouldnt switch on, i removed on off switch cover and used a short piece of wire across the brown wires flicked the wall switch and it worked, aha i thought faulty switch aquired a new one to no avail and now even the short piece of wire trick doesnt work, has the motor died do you think, it wasnt over heating or making strange noises prior to refusing to work

It could be the motor. I'm having to replace the brushes on my DC 05. It appears that you can only get brushes for the YDK motors in the DYSON, not the Panasonic motor. Which might be saying something about the YDK motors. What happens is that the ca ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

Dyson dc25 schecking continuity on reset switch its a 91 series 2 amp switch but whether i have button pushed or not a get continuity shouldn't this break when button is pushed

... Dyson DC25 All Floors Bagless Upright Vacuum

Dyson dc19 smoking when switchedon & turns off

... Vacuums

Altrev, I have an ODC325 Black&Decker spacemaker coffeemaker on my boat and it stopped working this weekend although the hot plate still gets hot. I suspect it is the thermal switch as you described (I hear a click when I switch the machine on but nothing happens and the heating element does not kick in). I would be very happy to receive one or two of these 14 spare switches you mention so I can repair the unit. If still available I would appreciate hearing from you how we can do the transact

We don't sell parts individually on the site here.... was it some other solution for another person you saw about the switch? I don't believe there really is a part called a thermal switch... there is a thermal fuse but if the hotplate gets hot I wo ... Vacuums

We have a dyson 07 and I am guessing the switch needs replacing as it won't stay running unless you hold the switch down. How do you change the switch?

Hi its Darran at Dyson.We can arrange for an engineer to repair your machine for you. If you would like to arrange this, please contact our Helpline on 0800 298 0298 (UK) or 1866MYDYSON (US).Kind regardsDarranDyso ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

I press the on/off switch on the Dyson DC05 and the vauum cleaner switches on unfortunately when I stop pressing it it switches off again. Please advise how I would need to repair this. Many thanks. Regards Michael Segal

If you can make it work by holding the switch down then it must be the switch or a bad connection on it. The only way to find out is unplug the machine from the mains and remove the switch to check it. A replacement should be cheap enough.pete ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

Replacing the on/off switch on Dyson DC07. After the switch retaining screw is removed, how is the switch removed? Does it just pull out or are there retaining tabs ?

Have a look at www.dysonmedic.com which has some great info on your machine ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Switch is not working I want to change it but I cannot access it.


Dyson DC07 The plastic pre filter catch snapped on my Dyson. I have a replacement already, but can't figure out how to remove the bottom of the broken one. It looks easy enough to slide/snap the new one in but accessing the old one isn't easy. What do I need to do to get it out?

Turn your dyson over so you can get to the bottom undo the screw and then you can see the bottom of the clip a gentle tap with with a screw driver blade will knock it out and the other one slips in ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Dyson dc03 faulty cable The cable from the mains plug to the on/off switch has split and needs to be replaced. How do I gain acess to the switch ? I am a competent engineer but I do not wish to damage the switch/cover to repair/replace acble.

I've never worked on a DC3, but whilst the shape and position of the switches changes from model to model, most are secured the same way.\015\012\015\012If you look closely at the switch cover (the bit you press for on/off), there is usua ... Vacuums

I have a dyson dc04 vaccuum cleaner and i want to replace the cable to the switch how do you get to the switch

Hi there SmartAlec from NelsonVacuums.com.au here. This is a bit of a tricky one on your first go so be gentle. Basically what you have to do is lift off the switch cover t ... Dyson DC04 HEPA Bagless Upright Cyclonic Vacuum

BURNING SMELL My DC 07 has suffered from poor suction in the upright position for some time now but this morning it ground to a halt. It was if the motor had burned out. I turned it upside down and some small stones etc tumbled out. I tried switching on again and the motor kicked in but the smell was horrendous so i switched off immediately. If it's likely to be **** inside the motor area i don't no how to access it. I've removed for fixing screws but still unable to prise apart. Is it just the

Hi.\015\012\015\012Try this site http://dysonmanuals.llc.nu/ has service manuals covering removing the Dc07 motor. ... Dyson DC07 All Floors Bagless Upright Cyclonic Vacuum

My Dyson DC14 Blitz It will not switch on. I have checked the fuse in the plug and it is fine. I have also vreified that the switch is working by using a multimeter. I'm guesing that there is an internal fuse blown (or worse!). Any suggestions?

I ended up dismantling the Dyson in an effort to determine the problem. In doing so I discovered that if I rotated the motor backwards by a quarter of a turn, it came back to life. Rather odd really. The Dyson is working fine now, and event benefi ... Dyson DC14 All floors Bagless Upright Cyclonic Vacuum

My Dyson DC15 has suddenly become very reluctant to turn left. This is only the case when it is switched on and irrespective of whether the roller brush is running or not. When the cleaner is switched off it behaves as normal as far as steering is concerned.There is no obvious problem with the ball or steering swivel mechanism. Any ideas ?

Hi its Darran at Dyson. Although strange, I believe we have a solution. It sounds as though the cleaner head hose is blocked. When the machine is running the suction will be pulling against the bloskage causingt he hose to contract and p ... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

I need a Dyson DC 17 Total Clean exploded parts diagream that shows the switch assembly. There are two small springs and a small plastic part that were loose inside the switch assembly. This caused the vacuum to shut off in the full upright position which is the position you use when using the wand.

I don't have a full diagram for you, but I do have a photo of how they are meant to be assembled: ... Dyson DC17 Animal Bagless Upright Cyclonic Vacuum

Why does my dyson dc04 work for about 5 mins then cut out the wire on my dyson 04 needs replacin but i cant get the casing off. My DC04 cuts out after abou 5 minutes use. I think there may be a thermal cut-out somewhere?

Thermal cut out in coils of motor,you have not been keeping filers clea,I THINK.\015\012motor is avaliable ... Vacuums

Self-propel switch arm broke off where control cable was attached. Looking for instructions as to how to gain access to that switch arm to replace it.

Greetings from GoVacuum,\015\012\015\012This is a farily common repair on this model. What ends up happening is that when someone picks up the vacuum cleaner by the handle of the machine, which on this model also is the controller for th ... Hoover Self-Propelled WindTunnel Bagless Upright VacuumVacuum