Having problems with your Easy Flo EF2300 Central System Vacuum ?

Myu easy flow central vacuum wi not shut off - Easy Flo EF2300 Central System Vacuum


Answers :

This could be because of 2 things....

first, the on/off switch may have been accidentally hit and is forcing the machine to stay on at all times.

Second, the relay in the unit may be defective and stuck in the on position. Less than 5 years should be under warranty. The easy way to tell if it is this problem tho is to unplug one of the low voltage wires from the side of the unit. These are usually located near the power cord going into the machine. If the machine stays running it is the Relay. However if the machine shuts off, the wiring in the vac system may be crossed out somewhere causing the machine to stay on.
Repair Help & Product Troubleshooting for Easy Flo EF2300 Central System Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Myu easy flow central vacuum wi not shut off - Easy Flo EF2300 Central System Vacuum


This could be because of 2 things.... first, the on/off switch may have been accidentally hit and is forcing the machine to stay on at all times. Second, the relay in the unit may be defective and stuck in the on position. Les ... Easy Flo EF2300 Central System Vacuum

We just purchased a house with the Easy Flo central vacuum system. When we opened the canister to empty it we discovered a bag or something hanging down into the canister. It is covered with dust, dirt, hair and who knows what. Do we change it or clean it?


Hi Trudi,Yes, you can wash it in warm water with a mild \015\012detergent. Be sure that the bag is completely dry before putting it back on.Should you ever decide you want to replace it, just do a google search for your vacuum ... Easy Flo EF1500 Vacuum

I have an Easy-Flo SQ9050 central vacuum system and having a problem with it maintaining continuous suction. There appears to be no clogs, filter seams clear and it is not tripping the breaker. Is there something else I can look for.


... Easy Flo SQ9050 Central System Vacuum

Easy Flo Central vacuum will still work at about


If your getting and performance out of the system there is definatly not a clog. there is not such thing as a partial clog in a vacuum system because anything stuck in the pipe will become a full blown clog. if your hose is 10 plus years old i would ... Easy Flo EF2300 Central System Vacuum

I am buying a central vac system, can you tell me the better of the easy flo or nutone brand. I want the one with the least problems. It appears to me that the easy flo has fewer problems, thank you


Between the two brands... stay away from the nutone. If you can get it, the Beam, Eureka, or even the Electrolux and Kenmore(sears) would still be better. The warranty would be better on the Beam and Eureka (7 or 10 and one model is even 15 years) ... Easy Flo EF1525 Central System Vacuum

I was using my easy flow central vacuum, and shut it off. When I went to start it up again 5 min later, it would not turn on. I emptied out the filter, and reset the switch. When the reset button was pushed, it started up the vacuum, but the vacuum was not turned on in the house. It can only be turned on from in the garage and not on the actual hose. What is going on?


... Easy Flo EF2300 Central System Vacuum

My home has a central vacuum system hook-up but no vacuum installed. My friend upgraded his central system and gave me his Eureka Mega Boss central vacuum system and the accessories, including the pow


The power head requires 120 Volts. Some hoses have a receptacle in the handle for the power head plug, and the hose has a cord at the wall inlet end that plugs into a receptacle. Some hoses have a plug at the wall inlet end that plugs into a 120Volt ... Eureka 1810 Central System Vacuum

I need the owners operation manual for a Centra - Flo CF400 central vacuum system


... Vacuums

My easy-flo central vacuum will not start when i plug in the hose


... Easy Flo EF1400 Central System Vacuum

I have an Easy-Flo central vac unit. The handle on the electric hose has a switch on the handle. With the switch on ''O'' in the center, it's off. On the left, is the ''I'' position. The vacuum runs but the power brush doesn't. On the right is the ''II'' position. The switch won't flip that way. It feels stuck. It feels as if there is something underneath of it that won't let it push that direction. I have the switch out of the handle, but I can't seem to get the actual black casing around the


Switches are not usually designed to be dissembled.I would strongly suggest that you dont take the switch apart. you are better off getting a new one. then if you feel like it you can take the old switch apart and if it dosnt work you still hav ... Vacuums

Our Easy-Flo built in vacuum system will not turn off, even when the hose is disconnected. We have to turn it off manually. Could it be a short in one of the wall outlets causing this?


Some models have an on/off switch on the power unit itself. This switch is used to turn your power unit on when you are right at the machine. \015\012 If there is no switch on the power unit, unplug your power unit from the wall socket, loo ... Easy Flo EF1400 Central System Vacuum

I have a central vacuum system. When I disconnect the hose from a wall outlet the central canister does not shut down dispite my turning off the vacuum at the handle of the hose. The only way I can get the system to shut down is to pull the plug at the canister. What gives? Rob


What I'm hearing is the canister(Not the Powerhead) portion of the unit is running all the time unless you unplug it. this problem could be caused by a short in one of your low voltage lines running through the house. To determine that just unplug on ... Vacuums

My easy flo built in system wont turn on when the


If there is a switch on your hose, it may be broken. Your system powers on from the inlets via two low voltage wires that run from the inlets to the switch/relay at the power unit. Each inlet has 2 spring loaded pins attached to the low voltage ... Easy Flo EF1400 Central System Vacuum

How to unclog central vac pipe - M&S Systems AirVac AVP1200 Platinum Series Central Vac - 12,000 sq ft Bagged Central System Vacuum


... M&S Systems AirVac AVP1200 Platinum Series Central Vac - 12,000 sq ft Bagged Central System Vacuum

Changed the motor carbon brushes on my Beam central vacuum cleaner equiped with an IntelliWatch system. This system includes the Alutron DB100 module. This Alutron module needs to be reset so that the vacuum cleaner can operate properly. I believe that this module keeps log of running time and disables operation after a predetermined time. Can you help me with providing a reset procedure that will reset this module. Thanks


... Sunbeam Vacuums

Nutone central vac with little vacuum - Broan-NuTone CV350 Performance Bagged Central System Vacuum


... Broan-NuTone CV350 Performance Bagged Central System Vacuum

We just installed a Hoover central vacuum system. As soon as we plug it in the system starts even if the switch is off. If we disconnect the wire the system goes off. What did we do wrong?


You have either left the manual switch at the vac in the on position, or you have a low voltage short at one of your inlets in the house, or at the vac itself or where a pair of wires are connected together at a pipe junction. Carefully go back ... Vacuums

My central vacuum system will not shut off. I had


Please provide more infromation, especially brand. They do differ.\015\012The problem could be as simple as a bad switch to shorted wires somewhere that you need to locate. ... Vacuums

CENTRAL VACUUM SYSTEM


Disconnect the inlet piping from the unit and check the suction there. Be sure that the utility inlet on the unit is closed. If you have good suction, you have an open/broken pipe somewhere, or possible an inlet valve or vacpan that is not sealing wh ... Broan-NuTone CV353 Central Vacuum

Problem with Nu-Tone central vacuum system.


... Broan-NuTone CV350 Central Vacuum

System quit working green light on - Beam Industries 2775 Serenity Plus Central System Vacuum


Depending on the year of your machine, assuming it is the serenity blue, it may be the circuit board on the unit itself. The manual switch "should" start the machine, but if not it will be the circuit board inside the main unit. however.. ... Beam Industries 2775 Serenity Plus Central System Vacuum

While vacuuming with a beam central vacuum system it suddenly just lost power and suction.


... Beam Industries 875 Classic Central System Vacuum

Unit will not turn off. Have to unplug it. - M&S Systems ZX-6000 Bagged Central System Vacuum


You probably have a stuck relay or wires are touching. Pull the low \015\012voltage wires off the vacuum, if it keeps running it's the relay. You \015\012can try tapping with medium force next to where the low voltage wires \015\012are attached to th ... M&S Systems ZX-6000 Bagged Central System Vacuum

I have any easy-flo built-in vacuum. I recently had the bearings on the motor, top and bottom replaced. I put the vacuum back together and it mow has low suction power. There is plenty of suction on the side of the canister where the rigid tubing meets the canister body but little suction at the wall plates. Any ideas? Roger


There is either a blockage or a pipe is open somewhere. You should check the system at the wall valve without the hose to determine if the pipes are blocked or if perhaps the hose is plugged. If one of the wall valves is damaged or open, this will af ... Vacuums

How can I get a wiring diagram for my CV450? - Broan-NuTone CV450 Central Bagged Central System Vacuum


This is all I could find. Hope it helps!\015\012\011\011\011\011\011 ... Broan-NuTone CV450 Central Bagged Central System Vacuum