The vacum will run until the hose is inserted and then the motor shuts off. The vacum switch must be hooked up incorrectly. Do you have a schematic?


Answers :

Before trying to take it apart, check the hose for a blockage. Disconnect the hose at both ends, drop a coin in one end, lift that end of hose allowing coin to drop through. If it doesn't come through, there's a clog. You should be able to clear it by plugging the hose into the exhaust port of the vacuum, holding the other end to the in port, and turning on.
\015\012Another possible problem is a dirty afterfilter. Remove the air diffuser/tool holder on the back of the vacuum. If the filter is dirty, it blocks the air flow and the vacuum will shut off due to overheating. Remove it, connect the hose, and turn on the vacuum.
\015\012If you don't have a manual, you can download it at the below site. Click on the space under "older models", click on Ambassador III, and download.
\015\012Information for removing the air diffuser is on page 9.
\015\012
\015\012http://www.aerusvacuums.com/support/manuals/
Repair Help & Product Troubleshooting for Electrolux C101 Bagged Canister Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

The vacum will run until the hose is inserted and then the motor shuts off. The vacum switch must be hooked up incorrectly. Do you have a schematic?


Before trying to take it apart, check the hose for a blockage. Disconnect the hose at both ends, drop a coin in one end, lift that end of hose allowing coin to drop through. If it doesn't come through, there's a clog. You should be able to clear i ... Electrolux C101 Bagged Canister Vacuum

My hoover, self propelled windtunnel ,on off switch will not shutoff. the second the electrical plug is put in the wall socket, the vacum starts running and you cannot shut it down with the on off switch


... Hoover Vacuums

My powerhead shuts off on its own and then i must push the switch again.


Just had this with mine and I think it is the power wires embedded in the hose from the cleaner to the powerhead. Turn the cleaner on then work your way along the hose kinking it or moving it until the power head stops. Switch the power head on again ... Dyson DC21 All Floors Stowaway HEPA Bagless Canister Vacuum - Iron/Titanium/Yellow

Nutone model cv-350 vacuum motor will not shut off. I have to unplug system in garage. I disconnected wire to house vacuum inlets and motor is still running. There must be a reset on the motor. I have turned the external switch on and off and still no help.


Mine is the same, and it is the relay welding itself closed. The relay is switched by the low-voltage wiring that connects to the vacuum outlets, and it switches the motor on and off. Mine was welded in the energized position. I have cleaned and file ... Vacuums

Vacum will not turn off when switch depressed. Must unplug.


Hi there, if you need some help with your Dyson visit the support section at www.dyson.com.Kind regardsDarran Dyson Customer Service ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Power nozzle on E-series won't start when cold unless the red 'reset' button is pressed multiple times while also holding the trigger to 'warm it up'...this is w/the power nozzle off the floor - no restriction on it turning. Once it's been running and then turned off the button must be pressed w/the trigger to get it to run - again w/the nozzle off the floor. It also seems to shut off too easily while vacuuming. I replaced the motor,which didn't fix it. Is the reset switch next on my list? T


... Rainbow E series Canister Wet/Dry Vacuum

FB600 Electrophoresis System When I hit the start button it initially kicks on but as sonn as I remove my finger it shuts off. I think it must be a bad relay. Can I order a new relay and get a schematic to help me locate which relay it is? Thanks, ****


Your best bet is to get the schematic and find the proper relay. because that is for sure your problem! I would try contacting the company. ... Electrolux Epic 6500 Vacuum

I have a Electrolux Epic 6500 SR canister vacum cleaner. It is nine years old and for the past few weeks it has started shutting off for no apparent reason.The symbol for bag change lights up and it cuts off, but even after I have put a new bag in, it still does the same thing. Do you have any suggestions? There is a little button or switch that the top of the bag fits on. Do you think it could be the problem?


Your machine is probably clogged, look through the wands, look in the bottom attachment, to see if there is anything stuck there. You can also drop a marble through the hose itself to see if anything is stuck there as well. To unclog the hose try hol ... Electrolux Harmony Canister Vacuum - EL6985 Vacuum

I have a hoover windtunnel upright vacuum, It will not shut off and I have to unplug it to do so. If I take apart the upper handle and manually flip the internal switch it works just fine, only when using the external switch on the handle, wont shut off.


This is a common problem with this machine. The switch has too much resistance to be turned on and off with the switch button and rod. If you put in a new switch, ( # 28161075 ), your problem should be fixed. ... Vacuums

My Sanitaire Commercial vacuum SC5815 A-2 does not turn on. It is quite new and seems to be "totally dead." Serial number: 0632005978 It is firmly plugged in, I have tried numerous electrical outlets, and I have tried the on-off switch numerous times. I wonder if there is a simple circuit breaker switch somewhere on the vacuum that I could switch without going to a repair shop? Or, I wonder if some latch is loose that shuts off the current, but I have checked the latches and they are clo


... Electrolux Sanitaire True HEPA Upright Commercial Vacuum Red EUKSC5713A

Vacume Overheating My vacum is overheating and then shuts down for awhile but doesn't start again untill the vacum has cooled down.. Are there any heat-relays or something like that that could cause the problem ?


There will be a filter between the cylinder/bag and the engine. If your vacuum has a HEPA filter there will be one on the other side of the engine. Remove both of these and clean them out with water, allow to dry and replace. ... AEG Vacuums

I have an easy flo vacuum model # 199C and it won't shut off. It started out as an intermitent problem but now will not shut off when the hose is unplugged, nor when the off/on switch on the main unit is shut off. the only way to get the motor to stop running is to unplug the unit. Any ideas?


Just had this same problem. I unplugged the low voltage signal wires and the vacuum stayed on. Thus eliminating the possibility of the signal wires shorting out somewhere. I'm not really sure which wire(s) were causing the problem. But when I disasse ... Easy Flo EF1500 Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?


... Vacuums

My electrolux ambassador power wand quit working. I replaced the switch that shuts it off when the roller stops, but it wasn't the problem. The on/off switch is fine, the motor is fine. We have traced the problem to the wires inside the canister by opening the inside cover to the bag container. We see the power cords going into the canister but we're not able to get to anything. We can't find any screws to undo that would open it up in order to follow the wires deep into the canister. We've bypa


... Electrolux Vacuums

Oreck schematics Did you ever get the schematics in pdf or a clear picture? I need the same thing to hook up my lights. Accidently burnt them out due to improper connect.


... Oreck XL Ultra Bagged Upright Vacuum

I need a Dyson DC 17 Total Clean exploded parts diagream that shows the switch assembly. There are two small springs and a small plastic part that were loose inside the switch assembly. This caused the vacuum to shut off in the full upright position which is the position you use when using the wand.


I don't have a full diagram for you, but I do have a photo of how they are meant to be assembled: ... Dyson DC17 Animal Bagless Upright Cyclonic Vacuum

My lux 7000 has a new bag but when i start to use it with the power unit or without the unit shut's it self off i can reset the lites or the motor if you will by clicking the on off switch 4or 5 times and i'm ready to go again untill you start to work and off it goes you can repeat the switch thing as long as u want, it just won't let u vacuum ,it turn's it self off .I blew it all out but found nothing in it. if u don't try to vacuum it will run as long as u want to listen to it. Can you


Have you replace the afterfilter? It may also cause this if rather dirty. It's located under the tool caddy/air diffuser on the back half of the machine.\015\012Try this: Disconnect hose, turn on vacuum. Does it continue running? If so, pl ... Electrolux Lux 7000 Bagged Canister Vacuum

I was vacuming with the hose only with my kirby generation 3 vacum and it suddenly made a different sound and smelled strong of burning. I immediately shut it off and unplugged it. It IS about 30 yrs old. Do you think it is worth taking in to pay someone to look at it or it just bit the dust?


It might be the belt and if it is it will be a sipmle fix. If it isn't I think It's time to bite the dust and buy new. You won't believe what you old vacuum was not sucking up and for what it would cost to repair vs buying new it would be about the s ... Vacuums

When switching the vacuum (DC17 Animal) over to the hard surface setting (so the beater brush is not spinning), the vacuum shuts off. I cleaned the dust bin and checked the filter. I also cleared the beater brush of hair or debris that was wrapped around it. It still shuts off. Ideas? Thanks.


The drive belt has probably broken. You can get a replacement belt here:Dyson DC17 Belt ... Dyson DC17 Animal Bagless Upright Cyclonic Vacuum

Electrolux Oxygen Upright 5035: Shut down after 5 minutes of normal cleaning with hose. Power to switch OK with Fluke Tester. Neither vacuum motor or the brush elevator works.(2 different switches)


Hi from uk may i suggest you try this ? recheck as you have done that although you have power to the switch ? you may not have the neutral wire feed back to the plug to complete the elec circuit have come across this problem many times and ... Electrolux Vacuums

My vacuum cleaner will not shut off when turned on. I have had it serviced twice by Sears, and for the third time I have experienced the same problem. I disassembled the upper have and it appears that the plastic mechanism designed to turn the switch on and off does not always catch the switch. Is there a way to fix this problem.


Put in a new switch, like toggle switch or use one off an old junk vaccum ... Hoover U5453-900 WindTunnel Supreme Bagged Upright Vacuum

I have a Euro -Pro select steam cleaner with soap dispenser and the off /on switch is not working properly. It doen't shut off once the steam is built up. Can I order a new hose so I can get a new switch? Thank you, Diane Prey


... Euro-Pro Vacuums

I bought a Eurika upright vacum (the boss whirlwind lite) it is pretty new, keeps shutting off before i am done vacuming, and the hose doesnt **** very well!!!


Your model mite have a divice that turns the motor off if it heats up if so take it to a repair shop and have them look at it ... Vacuums

NuTone CV750 Central Vacuum won't shut off. The on/off switch on side of unit has no effect. Did continuity test on switch, it tests ok. I've disconnected the low voltage wiring at the side of unit, that had no effect.


I will assume that you disconnected the switch from the circuit when you did the continuity test -- that is really important.\015\012If so, then i think that the relay inside the top of the unit is stuck on, or the low voltage wires (inside the ... Broan-NuTone CV750 Central Vacuum

Windtunnel bagless vaccum model uh6000 on/off switch no longer working, must plug/unplug unit to use. Can switch be replaced?


Hi, \015\012\015\012Yes they can be replaced and are relatively easy to fit. In my opinion, Hoover are one of the best vacuum manufacturers when it comes to obtaining spares and you should have no problem getting one. I did a (very quick) ... Hoover Vacuums
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0511 seconds