Having problems with your Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum ?

My electrolux canister oygen vacuum cleaner will not turn on when plugged in. it quit working when I disconnected the hose while running? It does not have power when plugged in to the electrical outlet


Answers :

This is often caused by a failure of a fuse on the Sumo board, or\015\012occasionally by a failure of the cord reel. Here are some instructions on how to check these things as a\015\012response to a different thread, but I will repost them here:
\015\012
\015\012--
\015\012There is a board in the back (called the "SUMO board") which has a fuse\015\012hardwired to it. Most of the "no go" problems with this machine are\015\012related to this.

In\015\012order to check it, you'll want to take a thin flat-head screwdriver,\015\012and gently pry up the silver panel on the top of the machine. The\015\012easiest place to do this is on the side of the panel, as far toward the\015\012rear of the machine as possible.

You will then need to remove\015\012the 2 Torx screws on the rear panel, and the top body of the machine\015\012should then be able to be removed. There are two clips in the bag\015\012chamber, directly under the back portion of the bag compartment lid,\015\012which can be pressed in to facilitate removal of the back cover.

The\015\012sumo board will be sitting directly on the top of the machine, and the\015\012fuse in question will be on the right if you are looking at it from the\015\012rear of the machine. Unfortunately, if the fuse is blown, you will have\015\012to replace the entire circuit board. (Unless you feel very comfortable\015\012with soldering a new fuse onto it, which I do not recommend for safety\015\012reasons.)

You can also check continuity of the cord reel from\015\012here. On the right hand side of the board are two spade terminals\015\012leading to wires running down into the cord reel assembly. One black,\015\012one white. Checking the continuity between these terminals and the ends\015\012of the power supply cord will allow you to determine if the cord reel\015\012is providing power to the machine.

Accessing the cord reel\015\012will require you to remove the six Torx screws holding the main body to\015\012the base. Two of these are on the rear of the machine, and are very\015\012deep inside; so you will require a very long-shanked Torx driver to get\015\012at these. Two more are inside the bag chamber at the rear, and the\015\012other two are on the front handle assembly. This will allow you to lift\015\012the main body away from the base, and if you are replacing the cord\015\012reel you can pull the wires from the spade terminals and the socket on\015\012the sumo board, and feed them back down into the cord reel chamber to\015\012remove the old cord reel.

Reassembly is simply a reverse of\015\012the previous. Beware, however: getting the cord reel to align is\015\012something of a chore, so make sure that you have the retraction system\015\012functioning before you put the whole thing back together, or you'll be\015\012bummed when you finish reassembly and the cord won't retract.
Repair Help & Product Troubleshooting for Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hooked everything up per directions. I plugged it in to the closest electrical outlet and nothing happened. The lights did not light up, the connected wall control and sensors leds do not light up. It appears the unit doesn't have power. The electrical outlet socket is fine as everything else I plug into it works fine. I have tried every other electrical outlet available. The unit won't power on from any outlet, and all of those outlets run other things, like power tools an refrigerators


Dear Davehibshman,Firstly; dismantle the plug and replace the fuse with the same rating as the one you have just taken out. Replace the plug cover, put the plug into the socket and try again. If this doesnt work, there may be a problem wi ... Vacuums

My electrolux canister oygen vacuum cleaner will not turn on when plugged in. it quit working when I disconnected the hose while running? It does not have power when plugged in to the electrical outlet


This is often caused by a failure of a fuse on the Sumo board, or\015\012occasionally by a failure of the cord reel. Here are some instructions on how to check these things as a\015\012response to a different thread, but I will repost them here: ... Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum

Electrolux Centralux I have a Electrolux Centralux. When I plug the hose in at one of the wall outlets the motor will not start. If I go to the motor and slap the unit it will start.....then...it will not stop unless I unplug the power cord to the motor. If I plug the power cord back in, the unit will not restart until I slap the motor unit again. The unit has only been used 20 - 30 times. Any suggestions?? Thanks, Bruce


I dont know if you had your unit looked at yet but it sounds like the Power module is going. I repair the machines so I know some of the work. ... Electrolux Centralux Vacuum

When plugged into electric outlet(checked power OK) the indicator icon on the top of the vacuum is not lit and the vacuum will not operate?


If the power indicator is not working, and your outlet is okay, then the problem is going to be in the cord or wiring. Carefully check the visible portion of the cord. If there are any cuts, or insulation scraped away, take the machine to an author ... Electrolux Epic 6500 Vacuum

I have a Kenmore central vacuum cleaner model number c107 34601. We have emptied the bucket and shaken the filter out to clean it. There is a filter that is filthy so we shook it out into a bag but the cleaner still seems to not have great suction. I notice there is a similar cap to the outlets I plug the central vac hose into on the unit itself that doesn't power the nozzle when used. 1 - what is this for? 2 - Should I somehow remove the entire filter and if so - can you tell me step by step ho


... Electrolux Vacuums

I have a nutone 350 central vac system and will will not start. Plug in the hose and I can hear a buzz at the unit like it is getting power but is not turning on. Does not matter what outlet I try


Your problem is incide the vaccum some object is stock , and the blower is cut. ... Broan-NuTone CV350 Performance Bagged Central System Vacuum

My central vac wouldn't shut off when I took the hose out of the wall socket, I have to plug and unplug the unit at the electrical outlet.


The start stop command is done by a small switch that is located in the wall socket - this command is then transmitted thru some wires at the relay on the control board of the unit, activating it and powering the machine.So you must check 3 thi ... Broan-NuTone VX475 Bagged Central System Vacuum

The power wand electrical connection on the power unit itself seems to be corroded. I think I need a new two wire plug to plug into the wand. the model is a Eureka 6984 A. I am able to disassemble the power unit if necessary and replace the wire and plug if one is available


Try hesco inc they have a on line store with all the vacs parts diagrams and fast shipping. ... Eureka Vacuums

Dyson DC23 Vacuum shut off and came on. Thought it was a problem at the electrical outlet as when moving plug it would come on again. Seen canister was full, emptied it and cyclone was quite plugged up so poked out the dirt. Had dog hairs in it as well as some ashes I had just vacuumed. Plugged unit in again and pressed switch. Will not come on. Tried another outlet. Is there a reset button somewhere or could the ashes have seized the motor. What can I try besides taking it to a repair sho


... Dyson DC23 Bagless Canister Cyclonic Vacuum

I have a 3 year old NuTone CV 353W central vac system and recently the switch on the hose handle does not turn the system on from any outlet in the house. I have to plug the hose into the outlet and then turn the unit on from the switch on the cannister. Any help would be greatly appreciated. Thanks


A great way to check if your switch in the hose is bad would be to turn the hose sideways in the inlet. If the unit turns on you most likely need a new switch. ... Broan-NuTone CV450 Central Bagged Central System Vacuum

Miele Champagne Vacuum Cleaner Model S548 I was using the vacuum as normal, moved locations so I plugged into another outlet & suddenly there was no power to the vacuum! I tried it in several other outlets, tried the reset button... & still no power to the vacuum. Any ideas what could be causing this? Any info would be greatly appreciated. Thank you!


Greetings from ,\015\012 \015\012This definitely sound like a cord reel issue to me. This is really the only problem that I ever see on a Miele vacuum cleaner. 9 times out of 10 the cord reel needs to be changed. If you purcha ... Miele Blue Moon Bagged Canister Vacuum

This Model likes to shoot electrical sparks between the plug and wall outlet when plugging in. I'm afraid I'm going to burn out an outlet.


This sounds might hazardous! Worry less about burning out an outlet, and more about the risk of electrocuting yourself!\015\012\015\012There's an electrical short-circuit somewhere, and the first place to look is the flex. Flex often gets damag ... Hoover U8311900 WindTunnel 2 Vacuum

Have a 2yr old Broan VX6000C built in vacuum. Has power when plugged in I have disconnected unit from the wall and the wires to the outlets are also disconnected and the power unit still runs as soon as it is plugged in???


... Broan-NuTone Vacuums

Power head attachment works great when plugged into the hose part of the vacuum. The problem is when I attach it to the tube for normal use there is no power. I have checked all the connections and switched the power switch on and off still no power from tube to power head. Is there anything else I can try? Model Callisto


Try having someone turn the machine on and off while you pull the cord in and out with the cord more angled towards the on/off switch. Sometimes these models have a break in the cord rewind and will not put the power through to the motor. ... Miele Vacuums

Miele Blue moon vacuum motor surging on and off and power light flashing. After many surges of the motor (on->off->on-> off etc), the motor no longer attempting to start as ferquently ie. now off for many seconds and may turn on for 1 second.. sometimes stops turming on and just power light flashes. There is also no voltage at the plug for the hose for the power head. I noticed that the vacuum first started having probs when hair was caught in the power head and the ovetrheating light went on


... Miele Blue Moon Bagged Canister Vacuum

No power I purchased last year and today it has no power. I have plugged it into several working outlets and nothing. It is completely without power.


See this step: God bless you Check the house circuit breaker to see if it tripped?\012 ... Bissell 21K3 CleanView Helix Bagless Upright Vacuum

The plug where plug in your hoses it look like plug outlet on the machine


... Minuteman C46200-00 Portable Carpet Extractor Vacuum

DC07 DYSON REPLACEMENT HOSE. HOW DO YOU REMOVE IT FROM THE HANDLE. I have a kenmore whispertone 8540 canister vaccum. The electrical wires (3) to power the beater are embedded in the hose, in a spiral fashion. The yokes that hold the hose on both ends (and attach to the beater on one end and the unit on the other) have no screws or pressure latches; i don't want to use brute force as i may damage the attachment device inside the yoke. If someone can tell me the trick to get these yokes off each


Should be a pry off dot on the underside revealing a screw ... Vacuums

I have a shark steam pocket was using it when it lost power . Tried plugging into different outlet still no power waited overnight no power.


If the power went out while using it then you have a major motor problem. It could be burnt out. ... Vacuums

Eureka 2961AVZ Will not start ...I get a momentary flicker of power about every 3d or 4th time that I flick on the power sw. Outlet is fine / Plug looks good / chord looks good / I see no obstructions ........Would appreciate any helpful thoughts ....Trying to get Mom's Eureka 2961avz back up and running. Thanks


CAREFUL! This is how my problems started. The cheap switches (and wiring) Eureka is using in some models, especially my model) should provoke a lawsuit imo.Here's my story, just in case it might help. Mine started with a problem very similar ... Eureka 2961AVZ Bagless Upright Vacuum

On my M&S Air Vac AV425 central vaccuum system, the system usually turns on by inserting the vaccuum hose into one of the vaccuum outlets. However, it now runs continuously. I am able to turn it off only by unplugging the vaccuum from the electrical outlet. I would like to know how to trouble shoot the problem or how to find someone who services Air Vac systems in the Bridgewater, New jersey area.


We are a central vacuum service company and we service all of new jersey. sounds like you have a short some where that keeps your unit running or it could be your relay module thats stuck our number is 908-721-7595 its j&j central vacuum services ... Vacuums

We have inherited a Filter Queen Majestic Triple Crown Model 99C vaccum and have no owners manual stating the year it was purchased and parts available. Our power hose electic wire connection (about 6 inches long) which plugs into the main unit is split in the hose attachment end. The motor sound went instantly quieter and I wondered if this was why when I found this frayed electical wire. It has not been used since this problem was found. How much is this single replacement part? I live


... Vacuums

Electric short Everytime I plug the vaccum into the outlet the outlet starts smoking.


Remove the electrical cord and check the conituity for a short. If one replace the cord. If no short is found the motor is fried although the switch would have to be on when it smokes so I think you have a bad cord ... Sharp Twin Energy EC-7311 Bagged Canister Vacuum

I have a Vacu Queen V3000 and it stopped working in the middle of a job. I verified that I have power at the outlet that it plugs into and then checked motor resistance from the plug and I got about 600 ohms. What is the problem?


EMRS, Hahah the same thing happened to mine... the lid cracked and I used PL Construction adhesive, it has held for a year, but needs constant gluing. Where can I buy a new lid relatively cheaply? Can't find one in Canada. ... Filter Queen Majestic Canister Vacuum

My 4 yr old Nilfisk vacuum cleaner has been working fine up until now. But suddenly, it has hardly any suction power and also, hot air seems to be coming out thru the vents on top and also thru the space that's normally used for blowing air OUT....the outlet with the retractable cover located close to the part where the power cable comes out of and retracts into. I've checked the filter and the hose and they are not clogged...I have also put in a new bag. Not keen to buy another vacuum cleaner u


Hi there SmartAlec from Nelsonvacuums.com.au here.It sounds like a blockage of some kind. The best way to find it is to set the machine up for normal vacuuming and remove o ... Vacuums