Having problems with your Electrolux Epic 6500 Vacuum ?

Bag was changed, but vaccum cleaner will not reset itself


Answers :

You could have a clogged hose, afterfilter, or worn/broken control valve assembly.
\015\0121. To check the filter, press the tab located at the bottom of the tool holder/air diffuser. See photo below. Lift air diffuser. There may or not be a filter here. If there is, remove it, then check machine operation.
\015\012
\015\0122. Disconnect hose form canister. Turn on machine. Place hand over intake. If the machine turns off during this process, the control valve assembly is broken or worn out. Replacement needs to be done at an authorized Aerus franchise service center.
\015\012
\015\0123. To check the hose, disconnect both ends. Drop a marble or similar size item in one end and allow to roll out the other. If it doesn't, the hose is clogged. This will cause the machine to shut off as well.
\015\012541b973.jpg
Repair Help & Product Troubleshooting for Electrolux Epic 6500 Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Bag was changed, but vaccum cleaner will not reset itself


You could have a clogged hose, afterfilter, or worn/broken control valve assembly.\015\0121. To check the filter, press the tab located at the bottom of the tool holder/air diffuser. See photo below. Lift air diffuser. There may or not be a ... Electrolux Epic 6500 Vacuum

Have a hoover windtunnel platinum. I have changed the bag ( hepa Q bag) but the bag light wont reset. so the vaccum wont turn on. I have unpluged it and let it set for a while with the new bag in and repluged it in. I have checked the brushes and it is all clean but it will not reset. This only the second bag so it is a new machine I should not be having problems. Is there some sore of reset button I can hit.


... Hoover Ultra U6430-900 WindTunnel Bagged Upright Vacuum

I have a hoover windtunnel platinum. I have changed the bag ( hepa Q bag) but the bag light wont reset. so the vaccum wont turn on. I have unpluged it and let it set for a while with the new bag in and repluged it in. I have checked the brushes and it is all clean but it will not reset. This only the second bag so it is a new machine I should not be having problems. Is there some sore of reset button I can hit.


... Hoover Company Wind Tunnel U53019 Upright Vacuum

I was vacuuming and noticed that the bag needed changing. the red light with the ! inside the triangle also came on. When the bag was changed, the vacuum would not restart. The red light came on. Tried the reset button but nothing happened. Tried unplugging and re-plugging in and nothing happened. Replaced all the filters and still it wouldh't start. So I brought it downstairs and tried one more time to get it to start. it worked! Is there something wrong with the vacuum cleaner? Was it overheat


It was overheated that is why it worked downstairs after cooling off. ... Miele S548 Bagged Canister Vacuum

Cleaner stopped working, changed bag still not working. Have checked mains fuse and liittle fuse on printed circuit board. When cleaner is on moving slider to the off positon the LED's glow red for a fraction of a second. Reset button does not feel as though it clicks when pressed, it does not seem to move. Many thanks, Hugh


... Panasonic MC-E583 Bagged Upright Vacuum

Vacuum cleaner does not start after getting warm, bag, that was full is changed, lights run across dispaly at top when I try to start it, cannot find my manual, can I download a manual for Excellio z 5240. Is there a fuse of something that has bo be reset?


... Electrolux Vacuums

Dc25 dyson upright vaccum cleaner. Brush inoperative. have changed on-off switch and the reset switch. the belt is intact and iam left with possible bad brush rotator motor???


... Dyson DC25 Vacuum

Vaccum Bag How do I change the vaccum bag? I no longer have the booklet. I keep hearing about a zipper. I can't find a zipper. There is sliding piece of plastic at the top. My bag is full, and I need to change it...Help!


Slide the plastic piece off the cloth bag and open the top. Looking down into the cloth bag, you will see the old bag. It is secured to the machine near the top. You will find the cardboard collar about a third of the way down. Remove it carefull. No ... Hoover Soft Light U4266-940 Bagged Upright Vacuum

Vaccum cleaner belt change


If you've put a new belt on and you still are getting a rubber smell, then odds are that your agitator (the rotating brush) is not turning freely, and that means either (a) you need to remove the end caps and remove any hair / debris that is under th ... Eureka 2961AVZ Bagless Upright Vacuum

Changed the motor carbon brushes on my Beam central vacuum cleaner equiped with an IntelliWatch system. This system includes the Alutron DB100 module. This Alutron module needs to be reset so that the vacuum cleaner can operate properly. I believe that this module keeps log of running time and disables operation after a predetermined time. Can you help me with providing a reset procedure that will reset this module. Thanks


... Sunbeam Vacuums

I have a BC-A41 vacuum cleaner which has been working well, but now it appears to blow stuff away from the cleaner as I hoover. I find the hose packed up with stuff, but no content in bag. I recently changed the bag...could it be that the bag is not fitted correctly..I am puzzled by the instruction to put the bottom under the rib. I am a pensioner on my own, and would welcome any help. Thanks, Jim


I think there should be some probem in the vacuum section..its failing to **** the objects ... Vacuums

I have a Miele S5980 vacuum cleaner, and recently had to change the Hepa filter. After doing the change, I tried resetting the reset button to switch off the Hepa filter indication light and it would not switch off. After a few tries, I accidentally depressed the switch, and it has dislodged from its cradle. Help, what can I do to fix this?


... Miele Vacuums

The check bag light comes on and vaccum quits but bag is not full. We changed bang anyway but vaccum would not start.


This is most probably due to a worn out or clogged Control Valve Assembly.Detach the hose and see if it runs. If it does, place hand over hole. If it shuts off, CVA is probably the cause. A clogged CVA is generally due to using gene ... Electrolux Guardian Bagged Canister Vacuum

I have a Electrolux Epic 6500 SR canister vacum cleaner. It is nine years old and for the past few weeks it has started shutting off for no apparent reason.The symbol for bag change lights up and it cuts off, but even after I have put a new bag in, it still does the same thing. Do you have any suggestions? There is a little button or switch that the top of the bag fits on. Do you think it could be the problem?


Your machine is probably clogged, look through the wands, look in the bottom attachment, to see if there is anything stuck there. You can also drop a marble through the hose itself to see if anything is stuck there as well. To unclog the hose try hol ... Electrolux Harmony Canister Vacuum - EL6985 Vacuum

How to open a electrolux ultra one vacumn cleaner model z8871p to change the dust bag


Canker Sores Vs. Cold Sores http://www.youtube.com/watch?v=iJ4mg3xrPDM ... Electrolux Vacuums

Electrical problem The light comes on but the motor will not come on when the on button is pressed. Is there a reset button? I thought it was because the bag was full but I just changed the bag and the motor still will not come on.


The light is separate from motor. No reset switch. Check for a fuse but i suspect it may be brushes are worn out and not making contact.Sometimes that starts as an intermittent.Hopefully one of the coils isn't open circuited. ... Sharp Twin Energy EC-12TWT4 Bagged Upright Vacuum

I have a Miele Vacuum cleaner MedicAir 5000 Plus. Recently the Dust Bag Indicator bar is full during normal cleaning and consequently the suction power is much less. I replaced the dust bag, engine pre-filter and Hepa filter but no change. When i remove the hose, the Indicator is normal, but when i attach the hose, wand, head, the indicator is full. I checked the hose, wand, head but can't see any blockage and when i blow with my mouth it seems fine. Can anybody help? thanks!


... Miele Vacuums

My cleaner ( Oreck 40th Anniversary, XL2 Ultra) several years old, and I love it. My questin, is there a reset button? Vacuum just quit....no noise, sputtering, smell, nothing, just stopped while running cleaner. New bag, new belt. Any ideas?


... Oreck Vacuums

Hi I have an electrolux "The Boss" hand held vaccum cleaner. I cannot find the instructions and am having problems changing the belt. It is model number Z57A. Product Number 900-250-006. It is the first time I have had a problem. I only use it occasionally for my caravan. So cant find the instructions and cant remember how to change the belt. Please help


You need top lace belt on brush roller and re[-assemble by putting plastic cover on which is retained by 2 recessed philips screws.. Prize off triangular coverat fornt.behing that you should see the belt lying loose.You need to get a blunt object to ... Electrolux Vacuums

Sebo upright vacuum cleaner - Bag full or clog light on constantly when using as an upright but not when using detachment pipe. Bag changed and no sign of blockage. Is this a common fault or does it need to be taken apart by an authorised repairer?


Hello,\015\012\015\012I have actually written an in depth trouble shooting guide on how to find the clog in your Sebo. Since this light is coming on only when you have the wand inserted into the vacuum and are vacuuming the floor, this i ... Vacuums

Vacuum cleaner hi.this is 10 yrs old and not overly worked.bags are changed regularly and the micro filter has been changed at least three times over ten years.it goes well for about 2o minutes then loses power with not much "suck"after that.sometimes shutting down completely,because of overheating i presume,or just carries on at a much lower'"suck".have tied shaking bag inside but no luck.any suggestions out there or can you tell me the agents support office for new zealand[auckland].many thank


What brand vacuum is it? ... Vacuums

I opened the cannister to change the bag and when I closed it the motor switch will not turn on. The second position which turns on the attachment for rugs still comes on. We thougth it was the switch so we ordered the part and it is still doing the same thing. Is there a reset button somewhere inside? The only reset button I see is on the attachment which is working.


It can be a few things. First check the overload protector located on top of the canister. If it has tripped the unit will not run. Push it in to reset. \015\012If that is the problem check the motor safety filter to see if it is clogged and caused t ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Bosch Vacuum Cleaner: I changed bag. Cleaned out all suction hose and hepa filters, however, my 1450 w 12 amp upright vacuum cleaner will die after five minute run - overheating. Please advise.


Greetings from GoVacuum.com,It sounds like you may have a bad thermal switch inside the machine. Most vacuum cleaners have a switch connected to the motor, so if the vacuum cleaner is running hot, it will shut off to prevent any damage ... Bosch Vacuums

We have an MC-3003 vacuum cleaner which keeps cutting out. We've changed the bag, but the problem still occurs with a new bag fitted. Could it be an electrical fault and is the machine repairable?


... Panasonic Vacuums

Hello, we have a Miele cat and dog turbo 5000 vacuum cleaner which we bought in December. It has just started blowing air out of the grid on the top of the cleaner instead of sucking from the tube. The whole top section which is opened to change the bags doesn't seem to want to clip down properly either. Do you have any ideas> I'm gutted as it was so good until this happened. Thanks Michelle.


The lid not closing properly is almost certainly the cause of your problem. Without that lid sealed tight to the body you will get no suction through the hose. So, the question is: why isn't the lid clipping down properly? Did you just change the bag ... Vacuums