Having problems with your Electrolux Epic 6500 Vacuum ?

Bag Full Sensor

\015 I have an Epic 6500 SR and the full bag light will not go out after I changed the bag. Based on another post it sounds like the full bag light switch is sticking. How do I get to that switch ? Thanks\015

Answers :

Opening The Unit:
\015\012Remove the hose, open the door, and remove the bag. Making sure that the door is open wide enough, pull the rubber strip on each side of the canister toward the opening until they are completely removed. With a little shifting, you will now be able to pry open the top cover from the bottom. Remove the obstruction sensor hose so that you can completely separate the halves.
\015\012Note: If the strips will not move toward the front, the you will have to slide them off to the rear. You will need two screwdrivers to pry open the top rear of the unit far enough to release the back cover.
\015\012Locating The Switch:
\015\012The "trip" switch is located on the inside top cover under the power button. The trip switch is activated by the sensor valve next to it.
Its a bad controll valve i would take it to a vacuum shop so you don't break your expensive vacuum trying to pry it appart.
Repair Help & Product Troubleshooting for Electrolux Epic 6500 Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hi there, I have an excellent Electrolux (but older) Diplomat LX model which stops when the bag is supposedly full. It''s not full however, but merely 1/4 to 1/3 full. I'd like to reduce the "sensitivity" of the sensor or turn it off altogether. I don't run my vacuum with a full bag, but there's a limit. Please tell me how to address this problem. Thanks very much. Pierre

... Electrolux Vacuums

Electrolux Epic 6500SR Full Bag sensor working, Does not Reset properly

The problem was a sticking switch that was not being reset. The vacuum on/off switch mechanism is comprised of two switches. One is the main switch that turns the vacuum on and off. The second is a shut off switch that gets tripped when the full b ... Electrolux Epic 6500 Vacuum

Cannister vacuum cleaner bag full sensor faulty.

... Electrolux Vacuums

My Windsor Sensor XP12 says the bag is full when it's not. I have removed the hose, brush, and filter and cleaned everything. I can put a bag on without the cover and it works great. However, when I add the bag to the front cover and close the latch the right way, it does not work. I'm thinking that the cover is not seating the bag correctly over the hole, but I can't figure out how to fix it. Any suggestions?

... Windsor SR12 Sensor Bagged Upright Vacuum

Bag Full Sensor

Opening The Unit:\015\012Remove the hose, open the door, and remove the bag. Making sure that the door is open wide enough, pull the rubber strip on each side of the canister toward the opening until they are completely removed. With a little s ... Electrolux Epic 6500 Vacuum

Windsor sensor says bag is full when its not

Are you vacuuming up fine particals like pet dander or just large amounts of regular dust? Also when was the last time you replaced your filters? \015\012\015\012Just some sugestions. ... Windsor SR12 Sensor Bagged Upright Vacuum

No power to sensor SR 12. I also have cleaned rollers and filters and bags. I have reset the handle. When I hit the power the check brush and full bag lights flash once. That is the only power that is getting through.The unit was in storage for a bit and got wet but its been drying off for a couple months. Is there something I can check or replace. Its a great Vac.

... Windsor SR12 Sensor Bagged Upright Vacuum

Series6500SR starts then stops-bag full light on-remove hose and it will run until Ipartially block the intake with my hand to simulate the hose. Bad sensor? how do Iopen this baby up? Can you send me parts?

There is an adjuster for the size of the dirt particles you are vacuuming on the top of the vacuum. Inside this adjuster moves an "O" ring up and down in a tube to adjust vacuum flow. The "O" ring is held in place by a plastic flange which is thin a ... Electrolux Epic 6500 Vacuum

Windsor sensor s15 bag full light comes on and machine shuts down

... Winsor Windsor Sensor S15 Commercial Upright Vacuum Cleaner

Electrolux 2100 new bag placed full bag indicator appears

It appears you have a bad control valve. My suggestion is to take it to your nearest Aerus dealer and have them replace it for you. You can find them by going to aerusonline.com and use their dealer locater. It shouldn't cost much to replace. You can ... Electrolux UltraLux 2000 Bagged Canister Vacuum

Full bag system works properly, but doesn't reset easily

Either there is something wrong with your switch. Which it doesnt sound like it. Take it to your dealer or call another one it sounds like the control valve needs to be replaced. I am a dealer 1-866-966-9350. ... Electrolux Lux 7000 Bagged Canister Vacuum

Full Bag Shut-off Comes on With New Bag and No Hose

The control valve has gone bad. This is the dial that you move on the top of the vacuum that has little indents on it.You cannot do anything to bypass this problem from outside the machine. This is not a repair that you can make you ... Electrolux Epic 6500 Vacuum

'Bag Full' light indicates at 1/3 bag

The sensor is a small hole into the vacuum chamber. It moves the alert system as vacuum inside the unit builds up.\015\012\015\012The filtration, built into the bag, is getting filled up and creating a higher vacuum inside the unit, givi ... Windsor SR12 Sensor Bagged Upright Vacuum

I have just replaced the bag in my miele and the indicator is showing that the bag is full. The air coming from the exhaust is hot and the machine is making a higher pitched sound as it does when the bag is full. When the hose is detached, the indicator registers as empty and there doesn't seem to be a blockage.

... Miele Vacuums

My electrolux vac shut off for a full bag. After replacing the bag the vac won't start and the bag full light stays on.What should I be looking for to resolve my problem?

If the suggestion that renevacdoc did not work, it is most likely that your valve assembly(full bag control) has gone bad and needs to be replaced. You will have to take your vac to the Aerus/Electrolux dealer/service store for repair. ... Electrolux UltraLux 2000 Bagged Canister Vacuum

Miele Red Velvet Vacuum bag indicator is showing full even with a new bag.

... Miele S558 Red Velvet Bagged Canister Vacuum

When i change the bag, the indicator strip shows a full bag. Can't get full suction.

You have a clog, either in the hose, the dirt inlet by the brush roll, or the filters are clogged. ... Vacuums

Vacuum bag indicator shows full bag but it is not full. Feels hot.

... Sebo Air Belt C2.1 Bagged Canister Vacuum

I replaced the bag full, but the bag full light stays on.

This is most likely due to a broken, worn, or clogged control valve assembly (CVA). You can try resetting the dial to the smallest dot, but I'm not sure that will work for you.\015\012Detach hose from vacuum. Turn vacuum on. If it runs, plac ... Electrolux Epic 6500 Vacuum

Aerus Lux 7000: the full bag light keeps coming on but the bag is not full.

Electrolux uses a pressure differential control valve. This valve measures air before and after the bag. There is a orfice or small hole where the hose connects to the vacuum cleaner, and a orice at the back of the bag canister. As the bag fills up t ... Electrolux Lux 7000 Bagged Canister Vacuum

I have a Miele Vacuum cleaner MedicAir 5000 Plus. Recently the Dust Bag Indicator bar is full during normal cleaning and consequently the suction power is much less. I replaced the dust bag, engine pre-filter and Hepa filter but no change. When i remove the hose, the Indicator is normal, but when i attach the hose, wand, head, the indicator is full. I checked the hose, wand, head but can't see any blockage and when i blow with my mouth it seems fine. Can anybody help? thanks!

... Miele Vacuums

My Dirt Devil M082476 Full Bag indicator light keeps coming on when I turn my vacum up to full intensity. I have tried changing the bag and checked that all hose is clear. If I leave the vacum on low intensity the suction is minimal and does not increas when I turn up the suction. Is there a solution to this? I look forward to your response

... Dirt Devil M084105 Jaguar Vacuum

It just keeps saying that my bag is full and cutting out, bag not full and have tried changing it anyway, but still cutting out

I would check the air filter. It sounds like it's over heating and shutting off because it doesn't have good airflow.Jim ... Sebo X4 Bagged Upright Vacuum

The machine keeps shutting off with a full bag lite everytime I turn it on..? the previous bag isn't full and it does it with a brand new one

The most probable problem is a clog in the hose.\015\012First detach the hose from the vacuum and turn it on. If it runs without the hose, you're on the right track. Detach the hose from the wands and drop a coin in one end. Lift the end so ... Electrolux C101 Bagged Canister Vacuum

While vacuuming the red light for the bag of the vacuum came on and the vacuum stopped. The bag was no where near full so I replaced it with a new bag - same problem. It vaccumes for a minute or then stops with bag light on. It is the correct bag for the machine - so what's the problem?

I'm assuming this is the Epic 6500 or similar model.\015\012Detach the hose, turn vacuum on. If it runs, place palm of hand against inport hole. If it shuts off the problem is with either the control valve setting or the control valve assembl ... Electrolux Vacuums
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy