\015 I used my sweeper about three weeks ago and it worked fine, and two weeks after that it will not work. We have plugged it into every outlet in the house. Nothing works.\015

Answers :

Greeting from GoVacuum,

On all Electrolux canister vacuum cleaners, there is a kill switch, that will not allow the machine to turn on without a bag in it. Sometimes when replacing the bag, the bag is placed in a position where the switch is not being activated.

When you open the bag housing, it should look like this;
91cabdc.jpg

You'll notice in the bottom right corner of the bag housing, the kill switch to the vacuum cleaner.
3594972.jpg

Try plugging the vacuum cleaner in, and while you are pressing this kill switch down, turn on the vacuum cleaner. Does the vacuum cleaner turn on/off when you push/release the kill switch? If it does, simply just get a new bag, and make sure that the new bag is covering the kill switch, and close the door of the vacuum cleaner.

If it still doesn't start, let me know and I'll try to help you diagnosis the machine differently. I'd say that 6 out of 10 times, this kill switch is the problem.

I hope this helps you. Please email me with any questions, or if this fix doesn't make your vacuum work. I really enjoy sharing my passion, and expertise in repairing vacuum cleaners.

Chris Jones
GoVacuum.com
[email protected]
Repair Help & Product Troubleshooting for Electrolux Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Electrolux ambassdor will not run after pluggen in


Greeting from GoVacuum,On all Electrolux canister vacuum cleaners, there is a kill switch, that will not allow the machine to turn on without a bag in it. Sometimes when replacing the bag, the bag is placed in a position where the switch ... Electrolux Vacuums

The motor running the beater bar on ny Electrolux canister vacuum cleaner runs intermittently. It runs about 2 minutes and then cuts off and automatically starts again after a 1 to 2 minute interval. I have tried taking it apart and removing the dust and grit in the beater bar attachment but with no change in operation. What would you suggest?


Check all the wiring connections to make sure they're tight. \015\0121/2. Wiring to power nozzle motor or reset switch is loose.\015\0121. Cord from power nozzle to upper wand. If the plastic portion of the wand is cracked near the co ... Electrolux UltraLux 2000 Bagged Canister Vacuum

I have an electrolux epic 6500 sr. The change bag light came on, I changed the bag, now it won't run properly. If the bag is out and the hose attached it will run or if the bag is in and the hose is off it will run, but not if the bag is in and the hose is attached. Any suggestions?


First, if it runs without a bag, there's a problem with the bag lock-out switch or wiring. This needs to be replaced/repaired by an authorized Aerus Electrolux technician.\015\012\015\012First, turn dial on top of vacuum counter-clockwis ... Electrolux Epic 6500 Vacuum

Electrolux 2 in 1 Ergorapido stick Vacuum. Motor runs then cuts out after 3 - 4 seconds. Sometimes it will run properly for 10 minutes so batteries are good. Why does it cut our usually?


If the hand held is working correctly (By itself) try pulling up a little bit on the 4 metal connection tabs on the wand. The connection tabs were not making a proper connection on my unit. ... Electrolux Pronto 2-In-1 Stick/Hand Vacuum - Cayenne

I have an Electrolux Silverado deluxe canister vacuum that won't run. It was running fine, I turned it off to move the plug and then it won't turn back on. It is getting power to the switch. Any help?


... Electrolux Vacuums

I have just purchased two (2) Electrolux Nimble vacuum cleaners. Not one, but both, straight out of the box, the beater bars will not run. It turns on, select carpet, and lower the handle, the red light to check beater bar/or filter lights up. You can reset the light by unplugging the unit, then plugging it back in, but with same results. Now the kicker, if you take out the handle, select carpet, lower the body by the carry handle, it will run and operate correctly, however, as soon as you r


... Vacuums

Electrolux nimble wont run only the roller brush


... Electrolux Vacuums

No suction on my Electrolux central vacuum in all outlets even though motor is running and there is no clog in the hose.


I would start with washing out the ilter really good and letting dry. then try the system. ... Electrolux Central Vacuum

Electrolux Diplomat LX temperature light came on and won't run now what should we do


... Electrolux Vacuums

Electrolux vacuum mod c153c canister runs for a short time then turns off and after about 10-15 seconds it turns back on again.


... Electrolux Vacuums

Electrolux Silverado has power to motor but will not run?


... Vacuums

Electrolux 2100 power nozzle motor doesn't run


... Vacuums

My Electrolux Pronto minivac runs when it's charging on the stick!


... Electrolux EL1000A2 Pronto Bagless Stick Cyclonic Vacuum

Electrolux Prolux Plus Commercial Heavy Duty Upright Vacuum Cleaner brush didn't run


... Electrolux Vacuums

Electrolux Prolux Plus Commercial Heavy Duty Upright Vacuum Cleaner brush didn't run


... Electrolux Vacuums

Have a electrolux aptitude model el5010. Motor runs, no blockagae, belt not broken. What's up?


... Electrolux EL5010A Bagged Upright Vacuum

When running the 2100 Electrolux vacuum, it is stopping and starting when pulling or pushing the floor attachment. Seems like the connection at the top of the handle is a little loose or the electric tabs are loose where the hose connects. Any ideas?


Other option is that on the hose end of the electrical connection, you can use an awl on the electrical connections to bend them in slightly so they make good contact when they are automatically plugged in when you connect the wands. HOWEVER, ONLY D ... Electrolux UltraLux 2000 Bagged Canister Vacuum

My electrolux canister oygen vacuum cleaner will not turn on when plugged in. it quit working when I disconnected the hose while running? It does not have power when plugged in to the electrical outlet


This is often caused by a failure of a fuse on the Sumo board, or\015\012occasionally by a failure of the cord reel. Here are some instructions on how to check these things as a\015\012response to a different thread, but I will repost them here: ... Electrolux EL7020A Oxygen 3 Ultra Canister Vacuum Cleaner Bagged Vacuum

The Electrolux Prolux upright vacuuum cleaner vacuum motor is not running and the brush is working well. What is the problem and how to open up the cleaner


... Electrolux EL5010A Bagged Upright Vacuum

I have a electrolux run shampooer Model B-8 A62612H how do i get the brushes off to clean


A quick twist counter-clockwise while pulling should do it. If not, contact an Aerus Electrolux store near you.\015\012\015\012http://www.aerushome.com/stor ... Electrolux Vacuums

Electrolux Diplomat canister vacuum. The bag light comes on and it stops. It has to do with the hose because if I take the hose off, then the vacuum keeps running. I can't see anything blocking the connection. any suggestions on what else to look at?


... Electrolux Vacuums

I just bought a good Sears Kenmore Progressive 300 upright vacuum (116.38812891) today at a garage sale for five bucks. I left my relic Electrolux with the new owners of my former home during a recent relocation. In the interim I bought a Bissel 3750H which I do not care for, and borrowed a Eureka 7685 AU which performs somewhat better. I cleaned up the Kenmore, and though it seems to run well, noticed the drive belt is showing signs of degeneration. I would like to replace it, but was unable t


... Vacuums

I have an Electrolux LE canister. It runs for about 2minutes then shuts off for about a minute , then turns on again and it keeps repeating this routine!!! It is driving me nuts. What part do I need to replace? Apparently it is over heating. Please help. Thank you.


The LE has a thermal cutoff. If the bag is overfilled or a bag breaks and clogs the bag chamber the vac will over heat. This also happens if the hose, wand or neck of the power head is obstructed. Try dropping a coin through the hose, look thro ... Vacuums

Epio 6500 canister electrolux won't stay running...says the bag is full even when it isn't. Will start but as soon a load is placed on the unit it shuts down. Any thoughts?


There might be something stuck ... Electrolux Epic 6500 Vacuum

Electrolux 5000 light is on where it normally says chande out bag. vacuum still will not run with hose on. with hose off works fine.


Clear solution here - the hose is blocked.\015\012\015\012\015\012\015\012Using a blunt stick with blunt ends, remove the entire hose assembly and compact up with the stick. Wriggle the stick a couple of times and this should dislodge whatever ... Electrolux Lux 5500 Canister Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0283 seconds