Having problems with your Hoover Elite Rewind Pet Bagless Upright, UH71003 ?

Motor shut off

\015 While vacuuming, the motor just shut off & doesn't work anymore\015

Answers :

Try it half an hour later, does it run? If so it's overheating. Change your filters and empty the cup.
If it does not run it's likely a problem with the cord rewind. Some of those units had a recall on the cord rewind. To find out for sure find a local hoover service center and take it in for repair many times at no cost.
Repair Help & Product Troubleshooting for Hoover Elite Rewind Pet Bagless Upright, UH71003

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

The motor is overheating and shutting off -- after vacuuming for a short time the vacuum motor shuts off


Sounds like there is a clog somewhere or a filter needs to be cleaned if it has one. Or the bag may need emptied.Jim ... Vacuums

I have a WD 14500 ridgid wet/dry vac. While using the motor shut off. There was no apparent reason or problem when I opened it up and checked it out. Why might the motor have shut off?


... Ridgid 9 Gallon Wet/Dry Shop Vac 96882 Canister Vacuum

Fantom vpw46h,house pressure washer.the motor runs,it was setting for sometime started,using it,but never had any pressure besides the house hose pressure, with the motor running,then the pressure startes to work great,while using it the wand hose came out of the pressure washer,i put it back in,now the motor will only run when i try to adjust the wand head but will not produce any pressure and will shut the motor off,it seem like as soon as the wand hose came out of the presure washer and after


... Vacuums

I have a Eureka Boss Model 411... I need to know where the reset button is for the suction motor. The canister was clogged on the backside, I didn't see it and the suction motor shut off. I have cleared the obstruction, but don't know where the reset is for that motor. I know how to reset the brush head motor.


If your vacuum motor overheats, it will stop working. it will start working again once it cools. ... Eureka 411A Upright Vacuum

Motor My vacuum cut out as I was using it. After some experimenting I found that the circuit reset had gone off. When I tried a second time while near the motor , there was a flash and again the motor shut off. At this time I am guessing that the motor is faulty. The central vacuuming is approximately 12 years old.


If it tripped the reset again, I would probably agree with you. Check out centralvacuum.com for another motor. They aren't the cheapest, but they have excellent support. Good Luck!! ... Easy Flo EF1400 Central System Vacuum

I have an easy flo vacuum model # 199C and it won't shut off. It started out as an intermitent problem but now will not shut off when the hose is unplugged, nor when the off/on switch on the main unit is shut off. the only way to get the motor to stop running is to unplug the unit. Any ideas?


Just had this same problem. I unplugged the low voltage signal wires and the vacuum stayed on. Thus eliminating the possibility of the signal wires shorting out somewhere. I'm not really sure which wire(s) were causing the problem. But when I disasse ... Easy Flo EF1500 Vacuum

Nutone model cv-350 vacuum motor will not shut off. I have to unplug system in garage. I disconnected wire to house vacuum inlets and motor is still running. There must be a reset on the motor. I have turned the external switch on and off and still no help.


Mine is the same, and it is the relay welding itself closed. The relay is switched by the low-voltage wiring that connects to the vacuum outlets, and it switches the motor on and off. Mine was welded in the energized position. I have cleaned and file ... Vacuums

Model # 5770 the brush motor runs and shuts down after a few seconds...Turn unit off and the brush again will run for a second or two...If I don't turn unit off brush will not start up..Could it be the printed board..the motor brushes..or the wiring that goes from the printed board to the main motor...Thank you


Seems like your unit goes into failsafe because it detects something wrong. Well you should check the brushes and replace them if they are worn out. Also check the wiring for shorts etc, becaue the unit maybe tripping due to an overload. The printed ... Bissell Vacuums

Hello, I have a problem with my Eureka Powerline bagged upright vacuum. It has a 12 amp motor and is model #4352, Type D. It was probably bought new in 1998. My problem is, while vacuuming today the motor seemed to slow down all of the sudden and then began smelling like burning rubber. I shut the vacuum off to check for blockages but could not find anything blocked. When I then turned it on again it runs but seems to only be running at 1/2 the motor speed and still has the rubber buring smell.


It sounds like a rubber sealing in the motor has come loose and is being constantly rubbed against the walls of the motor with would cause the smell and loss of motor speed caused by the fricton of rubber against the rod so if you can get to the moto ... Vacuums

I was just using my Bosch 1450W bagged vacuum and all of a sudden, the motor just shut down. No warning, no problems. The light still turns on, but the motor is unresponsive. There is a clean bag and filter, and nothing caught in the front roller. The motor sounded fine - no shaking, or weird frequency variations. There were no weird smells, just a little bit of heat, but nothing beyond normal. I've had this thing for several years, and never had a bit of trouble with it. Any suggestions


Many vacuums have internal thermal switches that need to cool to allow the vac to operate. After 30 minutes, check all 3 air filters and try again.\012Gary ... Bosch BSG71310UC Bagged Canister Vacuum

I purchased a Eureka C4910 last year and have a question that I am hoping you can answer. There are two motor actions with this vacuum, 1) the vacuum suction, and 2) the beater bar. The action of the beater bar is that motor is supposed to automatically shut off when the handle is in the complete vertical position assuming the vacuum is stationary, but then turn on when the handle is tilted toward the floor, assuming the vacuum is moving back and forth. The beater bar motor turn-on mechan


Good day!Normally when the motor is easily moved back and forth means that it have a proper lubrication,proper alignment and no clogs.When the motor and the belt is OK the problem could be on electrical wiring and switch ... Eureka C4910 Bagged Upright Vacuum

Oreck model BB870-AS - I was vaccuming when the vac shut off. The motor just spooled down and nothing more since. I have opened the case. Have power at the switch, and to the motor, but can't get a voltage reading to the common lead at the motor. Is there a fusible link, or something similar in that lead that might have burned out? Thanks!


... Oreck Vacuums

My vacuum cleaner will run for a few minutes and then shuts off. The plug light on the panel blinks. I thought the motor was shut, but after a long time it will turn on again, but again, only for a few minutes and then shuts off again. Any ideas? I bought an Oxygen Ultra a few years ago, but I don't like it nearly as much as the old Epic.


I know nothing about your particular vacuum, but many vacuum cleaners these days have\015\012safety cut out's, which causes the motor to do exactly what you describe. Sadly blockages, faulty switches, over stretched cables, carbon brushes etc c ... Electrolux Epic 6500 Vacuum

Vx450 cc vacuum motor keeps shutting off,bag


... Broan-NuTone VX475 Bagged Central System Vacuum

Motor howl the dc25 ball dyson when i shut it of the motor howls as it stops have cleaned all filters does not seem to help


... Dyson DC07 Bagless Upright Cyclonic Vacuum

Nutone central vacuum shuts off after a few minutes running then will restart after motor cools down I cheked motor and vent ports blown out all clean


Sounds like you have an overtemp switch that is tripping and shutting your motor off. Many motors use what they call a 'snap switch" ( looks like a small disk with two wires on it ) to sense motor temp and if that trips, then it will temporarily disa ... Vacuums

Shark infinity vacuum nv31c motor overheats. everything is clean and free of clogs. it will work for 3-4 minutes, then shut off. does the motor need replacing?


Mine takes longer to shut down, but I just started having this same problem. I wish I knew what's causing it so I could fix it. I think maybe we had a power surge at some point when I was using it last week. :( ... Euro-Pro NV30 Infinity Bagless Upright Cyclonic Vacuum

My Shop Vac (Brand) Mdl#934-16-11 keeps shutting off while I'm dry vacuuming. I can turn it back on then it will shut off again. The filter is spotless, so that's not the issue. There isn't any reset buttons. The only thing I can think of is that the float for wet vacuuming is somehow being sucked up causing the the motor to be tripped off. The vacuum is only about a year and a half old and used only sparingly. Help!


... Vacuums

I have to go into the garage to turn on the motor on the tank and to shut it off. When I plug the hoses into the outlets in the house, it doesn't turn on the tank motor. I don't know what part to get and nobody in Raleigh, NC shops can help me.


Is this Electrolux that's now known as Aerus? If so, take it in to the Aerus Electrolux store for a tech to look at. You can find the nearest Aerus Electrolux store by following the instructions on the site at bottom of page.\015\012\01 ... Electrolux Central Vacuum

Hoover u5781-900, motor shuts off (intermittent)when you shake vac or make jerky movements.If you move vac to up right position the vac starts right up.When you giggle vac, motor starts and stops no mater if you just started up or vac for ran for 45 min. Thanks Lucy C.


Lucy\015\012you have a bad connection somewhere in the unit\015\012this is a fire hazard and you should not use this until its been fixed\015\012could be a pinched wire or broken connections ... Vacuums

I just got a dirt devil cyclone quick lite for xmas and its wonderful, but in the last three weeks it shuts off by itself after just 10 minutes of vacuuming. I read the manuel and it says it has an automatic shut off when it over heats but 10 minutes? i mean it takes that long just to do one room and I have two floors the indicator on top is always green so I know its not the motor or service but is this the norm with these or is it just mine?


You have to blow out all dust every week,on all vacuums\015\012You really need an air compressor\015\012\015\012Remove the beater brush and clean the hair off end bearings\015\012Your motor is over loaded and circuit breaker i ... Vacuums

Central vac motor quit, blew fuse, when fuse reset motor makes a whirling noise and shuts off


... Vacuums

Our vacuum bag was full and we keep on vacuuming. I believe some lent and hair got sucked into the vacuum motor. We've changed the bag and filters. Now the motor makes a loud noise especially when shutting off. what should we do?


Get a professional repairer to examine it. Even with an over-full bag, dirt will not have got in to the motor if the pre-motor filter was correctly positioned and in good condition. However, the motor may have been damaged through lack of air flow an ... Miele S251i Plus Bagged Canister Vacuum

The motor overheats and shuts off. This annoying because it has done it at least 5 times today during normal vacuuming. It shuts off easily when you use the hose and canister to clean the steps or around the floor. What can I do to alleviate this problem?


Almost all vacuum cleaners have a thermal cut-out, which operates when the machine gets too hot and resets automatically when it cools down. Overheating is almost always caused by a blockage. Either the filters need cleaning or changing, or the ... Bissell Lift-Off(R) Revolution(R) Turbo Upright Vacuum

Thermal senser on the side of the vacuum motor there is a little thermal senser that has rust all inside of it ,my ? is will that cause the motor to shut down ,could the rust in the senser causing it to cut off ,cause the vacuum runs well then cuts off


If it is going bad, it will cause the motor to shut down, replace it then you will know if that is the problem or a problem with the motor itself. ... Vacuums