Having problems with your Hoover U5194-900 Mach5 Multi-Chamber Cyclonic Vacuum Cleaner Bagless Vacuum ?

It shut off and will not restart

\015 I have a Hoover Bagless Multi-chamber cyclonic. The model number is U5194-900 and the serial number is 040800130499. I was using my vacuum and it was stopped. I cleaned everything and let it sit for a while and it still would not not start again.\015

Answers :

All the filters have to be removed and cleaned or replaced
Repair Help & Product Troubleshooting for Hoover U5194-900 Mach5 Multi-Chamber Cyclonic Vacuum Cleaner Bagless Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

The machine shuts off!! will restart after a few minutes, but shuts right off again


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Acuum shuts down after few minutes but can be restarted but will shut down again


... Hoover U5750-900 WindTunnel Bagless Upright Vacuum

Why does my dyson slim dc18 keep shutting down, even though i keep it clean. Filters area is clean and all others have been properly blown out with air from a air compressor. It will work for about 5-10 minutes and then shuts down. Smells like ****, check the belt and a bit later it restarts again. It's seems to be almost over heating.


Maybe your motor is going. Here's a link to a site that talks about motor failure and replacement in a DC07 (not DC18). I don't know exactly what the odor smells like but maybe you can see if you have any of the other symptoms. Good luck! ... Dyson Slim DC18 All Floors HEPA Bagless Upright Vacuum - Iron/Titanium/Yellow

The machine shuts off!! will restart after a few minutes, but shuts right off again...


Http://www.geeksquad.fixya.com/ThreadView.aspx?prdid=0&thid=560313\015\012Generic problem for all Vacuums\015\012The machine shuts off!! Will restart\015\012Posted by mjzim ... Vacuums

DC07 Shuts Off, won't restart


If it was running for a while... It may be overheating. It has a reset: http://www.ehow.com/how_5943288_reset-dyson-vacuum.htmlBut maybe j ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Vacuum shuts down after a short time and needs to cool off before being restarted.


Trash it! ... Dirt Devil Reaction Twin Cyclone Upright Vacuum

Eureka Bravo with new belt & bag suddenly won't start. I replaced a very worn and slack belt with a new one, vacuum then ran for maybe 20 seconds then shut off and now won't restart at all. Bag was also changed at same time. Is there a fuse, maybe? New belt too tight? Thanks


... Eureka Bravo II Bagged Upright Vacuum

Electrolux vacuum brush not turning problem: was vacuuming and rug got caught auto shut off kicked off power to brush. instead of hitting red button to restart brush I disconnected brush to vacuum some hair in Conner. after i reconnected the brush and hit the red button but no power to brush. Light won't even switch on. Hope you can help


Under the vacuum, there is a guard.\012remove the guard , either by 2 screws or by 2 clips.\012there is a belt under the guard.\012that is connected to the brush.\012the belt need to be replaced. ... Vacuums

Hi, vacuum clogged and motor shut down, how do I restart. thx


I'm assumeing you have remove the clog so unplug the machine an let it set of about an hour then plug it in and before you turn it on get it ready to vaccum then turn it on the overload switch should reset and it should run ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Stops Immediately. We have a Beam Serenity model 2100 installed in the home and when the hose is inserted into the wall it turns on for a few seconds and then shuts off on it's own. Turning the handle's power switch off/on restarts the unit only to have it once again stop after a few more seconds. The canaster is clean. What could be causing this stopping issue? Thanks.


The Relay Control Board in the 2100 is bad. Replace and it should work just fine. ... Beam Industries 2900 Serenity Plus Central System Vacuum

After running for 15 minutes, the windtunnel vacuum cleaner shuts off. It will not restart until it has been off for 30 minutes. Could it be overheating for some reason. All of the filters are clean; the dust tank is empty; the belts have no cracks.


It's not necessarily overheating, but the thermal-fuse is definitely tripping and it takes 30 minutes to reset. There are several causes of this (in most common order):\015\012\015\0121. A blockage in the suction system or a full dust tan ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

My Roomba runs for about 3 minutes, then shuts off. If you push the buttons(S,M,L max etc) it will restart for another 3 minutes. The battery is new???


You will need to remove the debris off the cleaning head module. ... Roomba Robotic Floor Bagless Vacuum

After vaccuuming for less than five minutes, the vaccuum shuts off and we need to unplug it for 5 minutes before it will restart


It sounds like the motor is getting tripped out. It could be caused by having a clog somewhere in the unit, could also be that your filters are clogged. you have 2 filters on that unit. One is under the canister, looks like a drawer that slides out a ... Hoover U5780-900 Windtunnel Cyclonic Bagless UprightVacuum

Pushed button on small vaccum head shut off vaccum can not restart


... Hoover Fusion Plus Cyclonic Upright Vacuum Vacuum

After operationg for approximately 10 minutes my Dyson vacuum shuts off and wont restart for several hours.


... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

Nutone central vacuum shuts off after a few minutes running then will restart after motor cools down I cheked motor and vent ports blown out all clean


Sounds like you have an overtemp switch that is tripping and shutting your motor off. Many motors use what they call a 'snap switch" ( looks like a small disk with two wires on it ) to sense motor temp and if that trips, then it will temporarily disa ... Vacuums

It runs for a couple of minutes shuts off then restarts 30 seconds later runs a couple of minutes and does this over and over


Most vacuum motors are protected from overheating by a thermal switch that resets after cooling down. Check for blockage in the hose,\015\012power head or a full bag that would block cooling air from cooling the motor.\015\012\015\ ... Tristar Vacuums

Canister vacuum keeps turning off, can push buttons on wand handle to restart but shuts off again as soon as you start to move handle


Its sounds like the problem is either the power head wire which when your using it and twisting it left and right, turns it off.. Or it could be in the hose where the connect meets with the unit.Here's a number to call to further assist y ... Miele S548 Bagged Canister Vacuum

Vaccum runs for 2 or 3 minutes then shuts off. Can not restart it for several hours. We have tried EVERYTHING with no luck. I see there is the same problem with the VX550...is there a recall on this one too?


The VX series NuTone's have had some problems but NuTone is taking care of them as long as it is under warranty. You can contact NuTone at 1-888-336-6151 or whoever you purchased the unit from and you will most likely get a new unit. There are no p ... Broan-NuTone VX475 Bagged Central System Vacuum

Carpet attachment attachment appears to have poor/intermittent connection. When initiated, it works for <30 seconds before shutting down. Suction still works but carpet attachment doesn't. Near impossible to restart.


Mine became intermittant so I took apart the exteding wand section. I found that power is transmitted to the cleaning head through a ribbon cable which was damaged (burnt) from repeatedly adjusting the length of the wand. A new wand correct the probl ... Kenmore 25512/ 25513 Progressive Canister Vacuum

It shut off and will not restart


All the filters have to be removed and cleaned or replaced ... Hoover U5194-900 Mach5 Multi-Chamber Cyclonic Vacuum Cleaner Bagless Vacuum

Bissell Proheat model 8930 stops dispensing liquid after about 30-45 seconds when trigger is operated...occurs both with hose and upright modes. When shut down and restarted, dispensing resumes and again stops after another 30 seconds.


Hi,Here is a tip that will give you all the information you need to fix your BissellProheat Vacuum Problem.Bissell Proheat Upright Wet/ ... Bissell ProHeat Turbo Deep Cleaner Upright Steam Vacuum

Overheated and shut down. how to restart - Dirt Devil Reaction Twin Cyclone Upright Vacuum


Hi,\015\012\015\012You need to UNPLUG the vaccum and allow to cool for at least 30 minutes. The thermal fuse will not reset unless it is fully disconnected from the power source and allowed to cool. Simply leaving it for a while will not ... Dirt Devil Reaction Twin Cyclone Upright Vacuum

Central vac shuts down


... Vacuums

Turned off can not restart


It has an auto shut off feature if the motor gets to hot try unplugging it wait 30 mins then try again ... Eureka AirSpeed Pet Bag Upright Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0339 seconds