Having problems with your Hoover U5453-900 WindTunnel Supreme Bagged Upright Vacuum ?

My vacuum cleaner will not shut off when turned on. I have had it serviced twice by Sears, and for the third time I have experienced the same problem. I disassembled the upper have and it appears that the plastic mechanism designed to turn the switch on and off does not always catch the switch. Is there a way to fix this problem.


Answers :

Put in a new switch, like toggle switch or use one off an old junk vaccum
Repair Help & Product Troubleshooting for Hoover U5453-900 WindTunnel Supreme Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

My vacuum cleaner will not shut off when turned on. I have had it serviced twice by Sears, and for the third time I have experienced the same problem. I disassembled the upper have and it appears that the plastic mechanism designed to turn the switch on and off does not always catch the switch. Is there a way to fix this problem.


Put in a new switch, like toggle switch or use one off an old junk vaccum ... Hoover U5453-900 WindTunnel Supreme Bagged Upright Vacuum

My Electrolux Epic 6500 SR will not turn off by pressing on the switch button. I took it apart and removed the switch assy. I can maunually turn it off & on by pressing the rocker arm on the switch assy. It appears that the problem is with the big blue operator button, not the switch assy itself. The button does not seem to press down enough to cause the rocker arm to switch. The button has a "U" shaped wire that presses on the rocker arm and it may have some broken plastic details at the b


WOW !!! Finally You are dead on, absolutely 100%.... good work!!!.Get only a genuine new switch button with spring from an AERUS Electrolux dealer and reinstall. Then carefully reassemble the entire body and wiring harness.Con ... Electrolux Epic 6500 Vacuum

On-off switch My problem is finding a source for an on-off switch for an electrolux vacuum sweeper model 2100. I have replaced the broken toggle and now the sweeper turns on but only as long as the outside button is depressed. It appears that the on-off switch itself is broken as the switch does not ''hold'' when the toggle is activated. It seems to return to it's ''off'' setting as soon as the toggle is released. What ''holds'' the switch in its ''on'' position? Does it depend only on the on-


Hi Hugh. The 2100 has a rocker switch under neath the button. it is probably broken, or the button has a worn detent spring. If you would like, I could send you a switch kit with the rocker, button, and detent spring enclosed for around 20 dollars ... Vacuums

My Dyson DC15 has suddenly become very reluctant to turn left. This is only the case when it is switched on and irrespective of whether the roller brush is running or not. When the cleaner is switched off it behaves as normal as far as steering is concerned.There is no obvious problem with the ball or steering swivel mechanism. Any ideas ?


Hi its Darran at Dyson. Although strange, I believe we have a solution. It sounds as though the cleaner head hose is blocked. When the machine is running the suction will be pulling against the bloskage causingt he hose to contract and p ... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

My Kirby G 2001 upright vacuum wont turn on. I tried another outlet and still nothing. I don't see a breaker switch anywhere. If you know of any common problems I would love to hear them. I am very mechanically inclined, I just was wondering if there are any common issues with the motors or power switches etc. so I don't waste a lot of time troubleshooting. Thanks


This might sound a bit silly but check to see if the cord is plugged into the machine correctly if it is check to see if the safety interlocks are all engaged. ... Vacuums

We have the bissell quicksteamer and as I was shampooing I began to notice something burning so I unplugged our machine immediately; then my mom and I started cleaning all the filters assuming that could be the source of our problem and yes it was a little dirty but I suspected that it would take more thant that to cause our machine to somke soI turned it upside down and noticed there is a cable of copper threads that appear to have some type of rubber or plastic insulation tubing around it but


Was the exposed copper wiring on the electrical cord? If is then replace the cord. The main problem with this model is that Bissell obsoleted it as well as parts for it. But if all you need is a cord, you should be able to get one from a repair shop. ... Bissell 1960-3 QuickSteamer Plus Upright Vacuum

I have a Eureka Upright vacuum (4800 Series). When I try to start it by turning the switch on, it wont. For few days, I was able to get around this problem by repeatedly turning the switch on and off until it turned on but that does not work any more. Could it be something related to the switch it self or the power cable. My wife mentioned that one of my kids might have pulled the power cable too hard (at the back of the vacuum). Any help to solve this problem will be very much appreciated. Tha


... Eureka Smartvac 4870 Bagged Upright Vacuum

Hoover Upright Vacuum model U5470-900 - The On/Off switch on the handle does not properly engage the power switch deeper in the handle assembly. It appears to ride over the lower switch and doesn't engage it to operate it. If I play with it, I can get it to maybe turn on the vacuum, but, then the upper handle switch won't turn it off. Our current workaround is to use the power cord for on/off operation.


... Hoover Vacuums

The mechanical off/on in the handle is not working with the electrical on/off switch upon removal of the handle you can cut the machine off by hand but after ensuring the the handle is re-placed in the proper position the machine will not turn off so what new handle or is the rocker switch has worn is now to hard for the mechanical switch to operated


Hi there it's SmartAlec from NelsonVacuums.com.au here. You are spot on in your diagnosis however i have fixed heaps of these and i have found no way to tell wether its the ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Switch I have a kenmore 31913 vacuum and the on/off switch appears to be bad. My problem is getting into the switch. How do I open up the handle to get to the switch?


Go to this website\015\012and enter your complete model number in the search field in the upper\015\012right corner of the page. You should be able ... Kenmore 31913 Progressive Direct Drive Bagged Upright Vacuum

My Dyson DC 24's beater bar switch didn't actuate and the beater bar didn't turn. When I brought it to a certified serviceman he told me that a wire interferred with the switch and all he had to do was move the wire out of the way of the switch. At the time the machine was under warrantee and it didn't cost me anything. Now however, the machine is out of warrantee and the problem has returned. Does anyone know how to access the switch and move the wire out of the way?


Hi- I had the same experience but it turns out there's a small trip switch if you've taken the brush out to clean it, it needs to be reactivated by pressing the small red button to the right of the brush... took me a year to figure this out! Been mea ... Dyson Ball DC24 Bagless Upright Vacuum

RE: Goldstar dehumidifier: Model #DH404EY6, S/N 602TAQP05412 My unit is ~4 yr. old, has worked w/o problems until now. It will no longer auto. turn on. When I manually turn it on, the motor turns on, and then immediately shuts off, and "01" appears on the LED screen for humidity level setpoint. Is this an error code, and what does it mean? Can the unit be repaired? Thanks, Wolfgang


... Vacuums

I have a model u6476 self propelled hoover.The switch will not turn or off all of the time.The plastic slide does not operate the switch but slides over it.The switch seems to work easy enough by hand.Cleaner was purchased 2-23-07 Any iseas?


If the rod isn't pushing the switch, then something inside the handle asm. broke and isn't holding the rod in place. More often then not, it is the switch, but could be the rod in this case. ... Vacuums

My vacuum won't turn off when I turn the switch off. The only way to turn it off is to unplug it. What could the problem be?


... Dirt Devil M130005 Bagless Upright Cyclonic Vacuum

Shark s3325 stopped working while steaming; thinking the unit had ran out of water I allowed unit to cool before refilling, however unit over flowed with only 700ml water added. When I plugged unit back into outlet it would not turn on (red light was not on) but I hear a click upon plugging in unit, when turning unit power button on and when turning on the handle switch. Please advise how to resolve this problem.


... Euro-Pro S3325 Handheld Steam Vacuum

Proteam Pro force 1500xp Upright vacuum... When I switch to the carpet setting I have no suction power but the beater bar is turning. If I switch back to the floors setting, the suction is excellent. Wondering if the problem is in the on/off switch?


Just undo the screws on the front part of the switch assembly, carefully check all the leads to the switch. Mine slide off all the time as the switch is poorly designed and subject to damage when the darn thing tips over (easily!!!) new switches are ... Proteam ProForce® 1500XP Bagged Vacuum

Brushes stopped The brushes stopped turning while using the cleaner. I removed the brushes to see if the spindle was broken, it wasn't. I then removed the top plastic cover and checked the switch that engages the brushes; it didn't seem to be moving correctly. There's one spring on the switch - should there be two? Or do you think something has broken on the inside? Thanks for any help


Most likely the turbine is bad, it may just be clogged up, you can take it apart and clean it out real good. That may work, but it may not. Sometimes it is best to replace the turbine. ... Hoover F7431-900 SteamVac Vacuum

I have a Kirby G4 Vacuum Cleaner - MOdel G4 D. I have never had any problems or repairs done to it in the past ten plus years that I've had it. This is an upright vacuum. I was vacuuming the carpet floor and was not having any trouble at all. I switched the vacuum off and moved it into a different room. When I tried to turn on the vacuum, it would not turn on. I checked with different outlets, used both front attachment and hose attachment. Checked the front part of the motor/ spiral case. This


Hello,\015\012My educated guess is that it's either the switch or the power cord. Here are a couple of guides to help with diagnosis and repair...\015\012\015\012 ... Kirby G4 Bagged Upright Vacuum

I have Nutone VX550C. Motor runs intermittently (cycles on and off rapidly--the light on the handle is blinking furiously) when I use the on/off switch on the hose. This happens at all of the wall connectors, so suggests a hose contact problem. Motor runs continuously when I turn it on at the switch on the wall unit.


The unit does have a switchs the PVC outlets, and it sounds like the hose mech to operate the switches is broken, and intermittently making contact. A replacement hose would likely fix the problem. Looked them up on the net, and they're not che ... Broan-NuTone VX550 Bagged Central System Vacuum

The switch on the wall only works to control the fan and not the light- it won't turn off the ligght. I replaced the switch but it did not solve the problem


If this is a new installation and there was only one switch on the wall, say to control a light that was once there, then you have that switch hooked up only to the fan.\015\012If you want to control the light as well, it has to be wired up at the bo ... Vacuums

No suction Just received my refurb. dyson animal bagless. Finally figured out how to get it all together, turned it on and there is no suction coming up thru the beater bar. The hair is just collecting around the bar and not going up into the canister. It appears all the suction is going thru the open red end of the attachment hose, which has a vented cover piece. Am I missing a piece or is there a switch to turn of the attachment suction?


So the red hose isn't connected to a part on the vaccum so like it is connected to the connester but not to an opening just above the beater bar, this is the only idea i can supply you with. good luck, maybe i got lucky and helped you out. ... Dyson DC17 Animal Bagless Upright Cyclonic Vacuum

I have a self propelled Royal Dirt Devil vacuum model number 087900 and it goes backward fine but forward has to be pushed so hard it's impossible. Is this a switch? Do you know about how much the part would cost and can it be done by a beginner. We fix a lot of things ourselves but we aren't mechanics by no means. We put a brand new belt on it. I don't think it can be put on backwards and brush turns fine. Where is the switch? Use layman's terms.


You might try a new belt and/or brush roll. The brush roll is what helps pull a vacuum forward, the power drive helps, but if the brush isn't turning like it should, then it will hinder forward motion. The belt may look ok, but they stretch to the ... Vacuums

Shopvac 90L400 quit working (4 years old). Thought the switch was bad but not the problem. I read that there is a fuse link in the motor that frequently burns up. I tried to take motor apart but not sure of the process. I was able to get to the motor but cannot pull it out of the armature. It appears I have to take the aluminum blower unit off the shaft (it appears to be pressed on with a retaining washer). Do I have to take it off to pull the shaft and motor assembly out? Is that where the fuse


By pass the switch and take power right to the motor leads.. that should tell you if the motor is ok.. have not seen fuse link on a vac motor.. graingers has new motors, but not inexpensive ... Vacuums

Had my dyson root cyclone for about 4 years now, and in the last year it's had a few problems. About 4 months ago it started to make this awful grinding sound when the roller bar was engaged and I took it to a repair shop and they said it was the roller bar itself. The shop replaced the part and it worked fine for a couple of months and then it started to make the grinding noise again. I tried the clutch reset suggestion (turn it on its side and turn the carpet/bare floor switch slowly back and


Bdepends how much thay charged you for a roller brush because you can buy a good vac for about 100 pounds with a 12 month guarentee so its up to you ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

Will not turn on when I hit on switch. I have checked safety switch where head attaches but it doesn't seem to be a problem there.


Check fuse in the plug or better still if you have and can use multimeter check voltage present @ switch ... Kirby Ultimate G Bagged Upright Vacuum