Having problems with your Hoover U6426-900 Bagged Upright Vacuum ?

Our Hoover windtunnel has become VERY difficult to move!

\015 Ever since we had a new, deeper carpet installed, our "self-propelled" wind tunnel has become almost impossible to move. I have set the unit to "high" level, but it just seems to want to dig into the carpet instead of moving ahead.\015

Answers :

Repair Help & Product Troubleshooting for Hoover U6426-900 Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Our Hoover windtunnel has become VERY difficult to move!


... Hoover U6426-900 Bagged Upright Vacuum

Hoover Windtunnel smells like burnt rubber replaced belts brush doesn't spin when placed on carpet height adjustments won't move


Sounds like you have a bad brush roll(48414115), take it out and see the the ends turn freely or not, if not, then replace it. Also check the the slots that the brush roll sits in to make sure they haven't melted. I am assuming that the ... Hoover U5753-900 WindTunnel Bagless Upright Vacuum

Hoover self-propelled windtunnel U6430-900 flat belt gets hot & becomes hard to push. It has a filter bag. Purchased 8/2/01. Took one plate off bottom. Used a compressor to blow out dirt & dust. Put new thin belt on.


Belts get hot when fibers from carpet get wound arounf the belts mounting shaft. Best to take a razor and cut off any fibers so the belt doesn't get hot again ... Hoover Self-Propelled WindTunnel Bagless Upright VacuumVacuum

Can you help with this Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum ... hard to move on carpet


... Vacuums

Hoover windtunnel u5753-900 roller brush won't move on carpet


Suggest you replace the belt. ... Hoover U5753-900 WindTunnel Bagless Upright Vacuum

I have a Hoover WindTunnel, Self-propelled model, and it was working great until I ran over a portion of the cord, then it started making a bad noise and I noticed the roller is not moving consistently...I suspect I may have stetched the V-Belt...do you think so?


The V belt usually wears down first. Remove the roller and belt to visually check for wear and belt material in the roller pulley. I would change the flat belt as well. Also, replace the cord if any wires are exposed ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

I have a Hoover Windtunnel vacuum cleaner and new high pile carpet. The vacuum cleaner will not move forward without extreme effort. I have been told that I need a vacuum without a beater bar and that the beater bar can be disengaged. How do I accomplish that? Thanks


You can adjust the height on some vacumes like for bare floors and medium nap it will adjust how far the beater bar is from the carpet see if your is adjustable ... Vacuums

My Hoover Windtunnel Mach 6.9 brush roller quit working. Upon investigating I found that the idler arm pulley was broken so I managed to replace that. Before putting the cover back on I see the control knob for the roller brush moves a plastic piece left or right to activate/deactivate the brush roller. I don't know where this plastic piece connects. It appears to me that the idler are when raised creates tension on the belt which drives the roller. I'm at a loss trying to figure ou


Try this link belowhttp://www.ereplacementparts.com/hoover-u6630900-windtunnel-selfpropelled-bagless- ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Brush doesn't move when turned on - Hoover U5780-900 Windtunnel Cyclonic Bagless UprightVacuum


Replace both belts part # 38523-034 the V belt and 38528-035 the flat belt. Inspect the brushroll groove for wear. the top of the V belt should almost ride flush with the brushroll when you press your handle release and bring your head back. There is ... Hoover U5780-900 Windtunnel Cyclonic Bagless UprightVacuum

I have a Hoover Windtunnel Model #U5456-900 that appears t be stuck in the lowest postion. When I take apart the brush assembly, I do not see anything that the sliding level moves to adjust the height. Can you help?


... Hoover Vacuums

New main belt alignment for Hoover Windtunnel Mach 6.1. Belt moves 1/4 inch towards of vacuum cleaner and will not stay aligned on the V convex guide pulley


Http://geeksquad.fixya.com/ThreadView.aspx?prdid=0&thid=853508\015\012Generic problem for all Vacuums\015\012New main belt alignment for\015\012Posted by donle ... Vacuums

V-belt flapping on Hoover Self-Propelled WindTunnel Bagged Vacuum


... Hoover U6441-940 WindTunnel Bagged Upright Vacuum

Hoover WindTunnel Self-Propelled V Belt


I had this same problem with the V belt on my Hoover Vaccuum.\012\012There are three (3) basic things that will cause the brush roll not to spin.\012\0121. When handle is upright, brush roll is OFF.\0122. When switch is set for HARD surfa ... Hoover U6441-940 WindTunnel Bagged Upright Vacuum

Hoover Windtunnel Bagged upright vacuum is smoking and belt is slitting and burning


You probably need to replace your brushroll seeing that your belt is burning means motor is turning. first check you brushroll and see if there is an obstruction keeping it from spinning if its not spinning freely replace ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover windtunnel hose clogged - Hoover U6630-900 WindTunnel Bagless Upright Vacuum


... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Hoover windtunnel will not start - Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover Windtunnel My Hoover Windtunnel is 3 years old. It worked great until yesterday when it lost all suction. I have followed the manual to trouble shoot any possible clogs and could find none. Then I noticed that when I remove the dirt collection cup and held my hand over the vent the suction is fine and strong. So... I replaced the hepa filter thinking that might be the problem. That didnt' work. The motor runs fine. The suction without the dirt cup inserted is strong. As soon as you insert


Either the hose has a clog, or the inlet down by the belt is clogged. Is there suction at the end of the hose, if not then it is clogged. If there is suction, then it has to be clogged down below by the brush roll, check that inlet. There also is ... Vacuums

Hoover windtunnel bagless canister fuse - Hoover S3755 WindTunnel Bagless Canister Vacuum


... Hoover S3755 WindTunnel Bagless Canister Vacuum

Hoover windtunnel t series wont pick up - Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover windtunnel red light stays on - Hoover U6476-910 WindTunnel Upright Vacuum Cleaner Bagged Vacuum


... Hoover U6476-910 WindTunnel Upright Vacuum Cleaner Bagged Vacuum

Hoover windtunnel powerdrive w/bag


I am wondering if you have purchased the correct belt- there are two belts on your machine. Go to this site and have a look at the belts there. Also, if youno longer have your manual you can download one from this site with your MODEL # and it should ... Hoover U6311-930 Power Drive Bagged Upright Vacuum

Hoover Windtunnel My Hoover Windtunnel is 3 years old. It worked great until yesterday when it lost all suction. I have followed the manual to trouble shoot any possible clogs and could find none. Then I noticed that when I remove the dirt collection cup and held my hand over the vent the suction is fine and strong. So... I replaced the hepa filter thinking that might be the problem. That didnt' work. The motor runs fine. The suction without the dirt cup inserted is strong. As soon as you insert


Mine does the same thing. There is no suction. I found that there is a door that opens when you tilt the handle in the down possition. I think there should be a spring in place so it can open. Until I find a replacement spring I have to open the door ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Drive cable broken on Hoover Windtunnel - Hoover U6446-900 WindTunnel Bagged Upright Vacuum


... Hoover U6446-900 WindTunnel Bagged Upright Vacuum

How do I replace a hoover windtunnel belt - Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum


Here is a link to the manual and to the belts you need.\015\012\015\012\011\011\011\011\011\011U6439-900 Manual \015\012\011\011\011\011\0 ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Handle on Dyson ball does not click back into position. This means that when you are hoovering the handle moves back and forth as you move the hoover instead of it being