\015 I have a brand new hoover wind tunnel. while in the middle of vacuming it just turned off and now won't turn on agian. \015\012\015\012Ideas\015

Answers :

Have you tried to plug the vaccuum in another outlet that is on another breaker? It could be the vaccuum tripped the breaker. Turn the breaker back on. The manual mentions the thermal protector could have been activated. If this happened it resets and your vac should run after 30 minutes. I have a Widepath Tempo and it has tripped the surge protector. If this is the problem try turning some things off that are also on that breaker/outlet, or unplug them when you use the vac.
Repair Help & Product Troubleshooting for Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hoover Wind Tunnel bagless- issue with turning on


Have you tried to plug the vaccuum in another outlet that is on another breaker? It could be the vaccuum tripped the breaker. Turn the breaker back on. The manual mentions the thermal protector could have been activated. If this happened it reset ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

My machine (Hoover Wind Tunnel - bagless) is only 1 yr. old. The agitator brush doesn't turn all the time. I know it's not supposed to turn when in the upright position. However, it only seems to work when I have the setting on high. When I stop, but have not put the machine in the upright position, it stops again and then slowly starts moving. Could the V-belt be worn out already? In the owner's manual it states that this belt is not normally replaced. The exact same thing happened with my old


Sounds like you should do two things:\015\0121- Remove and clean the beater brush of all debris as best you can. At the end of the brush you will see a hard rubber piece, at both ends, that holds it in place in the body of the vacuum.\015\012Add som ... Hoover Self-Propelled WindTunnel Bagless Upright VacuumVacuum

Wind tunnel t series vacuum won't turn on - Hoover WindTunnel TSeries Bagless Upright Vacuum Cleaner UH70107


I had the same problem and used a tool to clean out the suction tube on my Windtunnel Series T. It was full of junk packed in tight. After cleaning it out there's no more turning off or overheating. It actually works better than when I first got it ( ... Hoover WindTunnel TSeries Bagless Upright Vacuum Cleaner UH70107

Hoover wind tunnel 2 bagless vacuum not working


Place handle in low position and turn cleaner over so bottom side is up.\015\012Remove the 4 screws in bottom plate and lift off.\015\012Look on the left side of the agitator brush. You should see the belt there. Remove agi ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Hoover Wind Tunnel does not turn on


That is a pretty good lifespan for a hoover, but its probably the power switch that's bad. Hoover uses a very poor quality switch. It shouldn't cost to much to have it replaced ... Kenmore 33721 Upright Vacuum

Need manual for hoover bagless wind tunnel


... Hoover Vacuums

The hepa filter popps out when I vaccum. - HOOVER COMPANY Hoover T-Series Wind Tunnel Bagless Vacuum


Secure it ... HOOVER COMPANY Hoover T-Series Wind Tunnel Bagless Vacuum

Hepa filter does not turn on hoover wind tunnel vacuum model U6630900. It was working (turning) and I cleaned the filter and canister and now it no longer spins when the vacuum is running.


The part you refer to is not the HEPA filter. It's a very common misconception that that part spins - it looks like it when there's dust whirling around it. In fact, it does not spin - there are no visible moving parts. ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Vaccum overheating I have a hoover u5458-900 wind tunnel and the auto shot off has kicked in for overheat protection. i've cleaned the entire thing and let it sit like i was supposed to but it still won't fully turn on and stay on. it will turn on for a few minutes and then shut off and just cycle like that for a few times. is there anything i can do to fix this or should i just clean it more (if possible)?


Either the motor protector is bad, or you have a clog in the hose or the dirt inlet by the brush roll. Are the filters clean? It is also possible that there is a problem with the motor. ... Vacuums

I have a Hoover Wind Tunnel Self-propelled vacuum. I changed the belts because the brush was not turning. After replacing the belts the brush is still not turning what can be wrong?


There are two belts on the wind tunnel this video will show you how to repair ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

HI, my motorized brush barely turns.It makes a hot rubber smell. I took apart and noticed the spindle the belt turns on discolored from heat. Cleaned it, but still no turning of the brush.The vac is a hoover wind tunnel. As it moved accidentally touched the belt/ spindle and burned my hand a little. Very hot in area. Bright spark from motor noted. Was careful not to touch that part!


That means that the belt is stretched and it is slipping on the motor shaft, that is why it is hot and smells like burning rubber. You need to replace the belt. Here is the correct belt you need: ... Hoover S3765-040 WindTunnel Bagless Canister Vacuum

Hoover Wind Tunnel V-Belt no longer turns brush


That is the correct belt what you dont see is a tension pulley that when the handle is released pushes on top of that belt giving it the tension it needs. try replacing the other belt, even if it isnt broken it could easily be stretched out ( all bel ... Hoover U6311-930 Power Drive Bagged Upright Vacuum

Hoover Savvy Bagless; wind nozzle doesn't turn


Has it been taken apart before? if so it wasn't put back together right.call me and i will walk you through putting it back together so it will work.i don't charge for the help just like to help people ... Hoover U8145-900 Savvy Bagless Upright Cyclonic Vacuum

Hoover wind tunnel vacuum will not turn off


You will have to replace the switch, Takeout the 4 screws on the back of the handle, it will slide off, then from the front, take out the 4 screws that hold the tool compartment on, it will then lift off and you can access the switch. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

I installed the Hoover Wind Tunnel Central Vac in my new home. After connecting the wall outlets and successfully turning on the system from the hose control, I discovered there is lots of air flow t


I would recommend checking your wall outlets where the hose plugs in for any type of clog in the tubing. If the vacuum itself ... Vacuums

My beater bar on Hoover Wind Tunnel 7500 has quit turning. I already replaced the belt. It worked for a while, but now it has stopped and is burning out.


... Hoover WindTunnel Rewind Upright Vacuum Cleaner

Hoover wind tunnel turns off after about 5 minutes


... Hoover Vacuums

Have Hoover Wind Tunnel Sel Propelled vacuum. Had to put on new drive belt. Turn on unit and drive belt slides off the drive spindle.


Look for excessive wear on the unit around the pulleys and their brackets that hold them in place. It sounds like something is just worn out and the belt is either slipping because it is not tight enough or because something is not aligned straight. ... Vacuums

Hoover, model # UH30070 Wind tunnel vacuum Brush won't turn. I do not see how to remove this to replace the brush, and besides it's only about a year old! Why is it already broken? There's no visible evidence on the brush that would make it stop, i.e. string, clogged, etc. Can you help?


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Where can I find an extension hose and wand for a hoover wind tunnel bagless canister model S3755 (59134002)


WHERE CAN I FIND AN EXTENSION WAND FOR MY EURO-PRO ULTRA STEAM SHARK II  EP908? ... Vacuums

Hoover wind tunnel cyclonic U5780900 1 year old. brush will not turn. too much slack in vbelt when in carpet position. Belt is good


Well, the V belt is normally fairly slack until the handle is dropped below 45 degrees, which is when the belt tensioner assembly drops into place. If turning the brushroll by hand when the vacuum is in this position fails to rotate the self propel p ... Hoover Vacuums

Wind tunnel by Hoover, vacuum will not turn off by using switch on upright handle. do not see a way to get to switch. modle no. U5458-900


Follow the cord and look for screws inside the bag compartment at the top. a panel should lift off allowing access to switch and cord. If swtch is melted it must be replaced with special hoover switch kit which has new wire and heavier duty switch. b ... Vacuums

My hoover wind tunnel cyclone will not even turn on why? no noise no lights nothing


The switch is known to go bad i replaced 7 so far this week ... Hoover U5753-900 WindTunnel Bagless Upright Vacuum

I have a Hoover Wind Tunnel bagless mach 4.7 vacuum that shuts off after about 30 seconds. I suspect it is overheating, but there are no clogged lines. The on/off switch is in good working order. Help!!


Is your filter clean? you should be able to see the pleats in the filter pretty clearly. also the metal screen that is next to the filter should be clean as well. if the problem continues it could be a faulty thermal protector ( a device that shuts t ... Hoover Vacuums

How to replace belt on Hoover U6626-900 Wind Tunnel bagless.


Hello,Click this to go to a site that will show you (complete with illustrations) how to change belt.http://www.info-vacuum-clea ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0763 seconds