Having problems with your Kenmore 25812 / 25813 Progressive Bagged Canister Vacuum ?

No suction..says bag full

\015 I just changed the bag...properly and when I switch the vacuum ON..it reads bag full and has no suction. What have I done wrong?\015

Answers :

You were right! Sure enough my problem was not a sock but a weird dried fig solid as a rock forming an obstruction that eventually enough lint built up that it formed a complete and total blockage. The fig was so tough that it almost pierced the hose. I went after it with a wire chase and once I noticed that it was about to pierce the hose in one place I managed to dislodge it with a counter twisting motion. Vacume on - Wooosh - Power and suction once again. Thanks I was about to go buy a new vacume!
There is most likely an obstruction somewhere in the system that is not obvious to you. Please inspect all hoses. I have seen a sock in a vacuum line before, it caused these same symptoms.
Repair Help & Product Troubleshooting for Kenmore 25812 / 25813 Progressive Bagged Canister Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hi there, I have an excellent Electrolux (but older) Diplomat LX model which stops when the bag is supposedly full. It''s not full however, but merely 1/4 to 1/3 full. I'd like to reduce the "sensitivity" of the sensor or turn it off altogether. I don't run my vacuum with a full bag, but there's a limit. Please tell me how to address this problem. Thanks very much. Pierre

... Electrolux Vacuums

I have just replaced the bag in my miele and the indicator is showing that the bag is full. The air coming from the exhaust is hot and the machine is making a higher pitched sound as it does when the bag is full. When the hose is detached, the indicator registers as empty and there doesn't seem to be a blockage.

... Miele Vacuums

My electrolux vac shut off for a full bag. After replacing the bag the vac won't start and the bag full light stays on.What should I be looking for to resolve my problem?

If the suggestion that renevacdoc did not work, it is most likely that your valve assembly(full bag control) has gone bad and needs to be replaced. You will have to take your vac to the Aerus/Electrolux dealer/service store for repair. ... Electrolux UltraLux 2000 Bagged Canister Vacuum

Miele Red Velvet Vacuum bag indicator is showing full even with a new bag.

... Miele S558 Red Velvet Bagged Canister Vacuum

The machine keeps shutting off with a full bag lite everytime I turn it on..? the previous bag isn't full and it does it with a brand new one

The most probable problem is a clog in the hose.\015\012First detach the hose from the vacuum and turn it on. If it runs without the hose, you're on the right track. Detach the hose from the wands and drop a coin in one end. Lift the end so ... Electrolux C101 Bagged Canister Vacuum

My Dirt Devil M082476 Full Bag indicator light keeps coming on when I turn my vacum up to full intensity. I have tried changing the bag and checked that all hose is clear. If I leave the vacum on low intensity the suction is minimal and does not increas when I turn up the suction. Is there a solution to this? I look forward to your response

... Dirt Devil M084105 Jaguar Vacuum

I replaced the bag full, but the bag full light stays on.

This is most likely due to a broken, worn, or clogged control valve assembly (CVA). You can try resetting the dial to the smallest dot, but I'm not sure that will work for you.\015\012Detach hose from vacuum. Turn vacuum on. If it runs, plac ... Electrolux Epic 6500 Vacuum

I have a Miele Vacuum cleaner MedicAir 5000 Plus. Recently the Dust Bag Indicator bar is full during normal cleaning and consequently the suction power is much less. I replaced the dust bag, engine pre-filter and Hepa filter but no change. When i remove the hose, the Indicator is normal, but when i attach the hose, wand, head, the indicator is full. I checked the hose, wand, head but can't see any blockage and when i blow with my mouth it seems fine. Can anybody help? thanks!

... Miele Vacuums

Aerus Lux 7000: the full bag light keeps coming on but the bag is not full.

Electrolux uses a pressure differential control valve. This valve measures air before and after the bag. There is a orfice or small hole where the hose connects to the vacuum cleaner, and a orice at the back of the bag canister. As the bag fills up t ... Electrolux Lux 7000 Bagged Canister Vacuum

Vacuum bag indicator shows full bag but it is not full. Feels hot.

... Sebo Air Belt C2.1 Bagged Canister Vacuum

It just keeps saying that my bag is full and cutting out, bag not full and have tried changing it anyway, but still cutting out

I would check the air filter. It sounds like it's over heating and shutting off because it doesn't have good airflow.Jim ... Sebo X4 Bagged Upright Vacuum

When i change the bag, the indicator strip shows a full bag. Can't get full suction.

You have a clog, either in the hose, the dirt inlet by the brush roll, or the filters are clogged. ... Vacuums

While vacuuming the red light for the bag of the vacuum came on and the vacuum stopped. The bag was no where near full so I replaced it with a new bag - same problem. It vaccumes for a minute or then stops with bag light on. It is the correct bag for the machine - so what's the problem?

I'm assuming this is the Epic 6500 or similar model.\015\012Detach the hose, turn vacuum on. If it runs, place palm of hand against inport hole. If it shuts off the problem is with either the control valve setting or the control valve assembl ... Electrolux Vacuums

Electrolux Epic 6500SR Full Bag sensor working, Does not Reset properly

The problem was a sticking switch that was not being reset. The vacuum on/off switch mechanism is comprised of two switches. One is the main switch that turns the vacuum on and off. The second is a shut off switch that gets tripped when the full b ... Electrolux Epic 6500 Vacuum

Full bag system works properly, but doesn't reset easily

Either there is something wrong with your switch. Which it doesnt sound like it. Take it to your dealer or call another one it sounds like the control valve needs to be replaced. I am a dealer 1-866-966-9350. ... Electrolux Lux 7000 Bagged Canister Vacuum

Bag full indication comes on; changed bag; still wont run.

Turn the knob on the top of the vacuum all the way to the right and try it again ... Electrolux UltraLux 2000 Bagged Canister Vacuum

When removing the canister bag, the plate and spring that it slides into popped out. When I put them back in, the bag full indicator is completely red. It is a new bag and filters. I think I am not getting the plate and spring back in the canister correctly. Any instructions or pictures showing proper insertion and configuration of these? I looked in the manual and the part is only shown while bag being inserted.

... Miele S514 Solaris Bagged Canister Vacuum

How do I clean the bag? I loaned it to someone that had 4 dogs! Needless to say the bag was very dirty, full of dog hair and smells really bad. I emptied the bag out but still cannot get all the hair out and wondered about how to clean the bag. Can I wash it? Thanks so much, Cindy

Yes you can wash it if it is from textile material, hand wash it i recomand, but not to sure if u can get all the hair out, but at least it will smell nice.\015\012\015\012A new bag isnt't to expensive either, depends on the model.\015\012\015\ ... Vacuums

My Windsor Sensor XP12 says the bag is full when it's not. I have removed the hose, brush, and filter and cleaned everything. I can put a bag on without the cover and it works great. However, when I add the bag to the front cover and close the latch the right way, it does not work. I'm thinking that the cover is not seating the bag correctly over the hole, but I can't figure out how to fix it. Any suggestions?

... Windsor SR12 Sensor Bagged Upright Vacuum

Bag light shows bag is full and shuts off.

It sounds like you have a bad control valve. The best thing to do is take it to an Aerus Electrolux dealer and have them replace it for you. It shouldn't be very expensive and they can probably do it while you wait. Good Luck! ... Electrolux UltraLux 2000 Bagged Canister Vacuum

Can't get the covers off Electrolux Model C102G, acts as if bag is full, but bag is new and empty!

... Electrolux Vacuums

13 yr Electrlux.Cuts off if hose plugs in.Says Bag Full-bag empty

Sounds like you have the plastic bodied canister. the controll valve inside is bad. I usually just disconnect those to avoid future problems. you may want to take the vacuum to a repair shop though becuase they are a pain to get apart and get back in ... Electrolux Vacuums

13 yr Electrlux.Cuts off if hose plugs in.Says Bag Full-bag empty

This sounds like the valve assembly (full bag control) is faulty or one ov the tubes is clogged. You will have to take it to the shop. ... Electrolux Guardian Bagged Canister Vacuum

Electrolux 2100 new bag placed full bag indicator appears

It appears you have a bad control valve. My suggestion is to take it to your nearest Aerus dealer and have them replace it for you. You can find them by going to aerusonline.com and use their dealer locater. It shouldn't cost much to replace. You can ... Electrolux UltraLux 2000 Bagged Canister Vacuum

Full Bag Shut-off Comes on With New Bag and No Hose

The control valve has gone bad. This is the dial that you move on the top of the vacuum that has little indents on it.You cannot do anything to bypass this problem from outside the machine. This is not a repair that you can make you ... Electrolux Epic 6500 Vacuum