Having problems with your Kenmore 33721 Upright Vacuum ?

Hoover Wind Tunnel does not turn on

\015 We have a Hoover Wind Tunnel Mach 4.7 that is 8-9 years old. It will not turn on. We have not had any previous problems. Is there a reset button or is the motor just bad? Should I be happy it lasted this long?\015

Answers :

That is a pretty good lifespan for a hoover, but its probably the power switch that's bad. Hoover uses a very poor quality switch. It shouldn't cost to much to have it replaced
Repair Help & Product Troubleshooting for Kenmore 33721 Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hoover Wind Tunnel bagless- issue with turning on


Have you tried to plug the vaccuum in another outlet that is on another breaker? It could be the vaccuum tripped the breaker. Turn the breaker back on. The manual mentions the thermal protector could have been activated. If this happened it reset ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Hoover Wind Tunnel does not turn on


That is a pretty good lifespan for a hoover, but its probably the power switch that's bad. Hoover uses a very poor quality switch. It shouldn't cost to much to have it replaced ... Kenmore 33721 Upright Vacuum

My machine (Hoover Wind Tunnel - bagless) is only 1 yr. old. The agitator brush doesn't turn all the time. I know it's not supposed to turn when in the upright position. However, it only seems to work when I have the setting on high. When I stop, but have not put the machine in the upright position, it stops again and then slowly starts moving. Could the V-belt be worn out already? In the owner's manual it states that this belt is not normally replaced. The exact same thing happened with my old


Sounds like you should do two things:\015\0121- Remove and clean the beater brush of all debris as best you can. At the end of the brush you will see a hard rubber piece, at both ends, that holds it in place in the body of the vacuum.\015\012Add som ... Hoover Self-Propelled WindTunnel Bagless Upright VacuumVacuum

Hepa filter does not turn on hoover wind tunnel vacuum model U6630900. It was working (turning) and I cleaned the filter and canister and now it no longer spins when the vacuum is running.


The part you refer to is not the HEPA filter. It's a very common misconception that that part spins - it looks like it when there's dust whirling around it. In fact, it does not spin - there are no visible moving parts. ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

Vaccum overheating I have a hoover u5458-900 wind tunnel and the auto shot off has kicked in for overheat protection. i've cleaned the entire thing and let it sit like i was supposed to but it still won't fully turn on and stay on. it will turn on for a few minutes and then shut off and just cycle like that for a few times. is there anything i can do to fix this or should i just clean it more (if possible)?


Either the motor protector is bad, or you have a clog in the hose or the dirt inlet by the brush roll. Are the filters clean? It is also possible that there is a problem with the motor. ... Vacuums

HI, my motorized brush barely turns.It makes a hot rubber smell. I took apart and noticed the spindle the belt turns on discolored from heat. Cleaned it, but still no turning of the brush.The vac is a hoover wind tunnel. As it moved accidentally touched the belt/ spindle and burned my hand a little. Very hot in area. Bright spark from motor noted. Was careful not to touch that part!


That means that the belt is stretched and it is slipping on the motor shaft, that is why it is hot and smells like burning rubber. You need to replace the belt. Here is the correct belt you need: ... Hoover S3765-040 WindTunnel Bagless Canister Vacuum

I have a Hoover Wind Tunnel Self-propelled vacuum. I changed the belts because the brush was not turning. After replacing the belts the brush is still not turning what can be wrong?


There are two belts on the wind tunnel this video will show you how to repair ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover Wind Tunnel V-Belt no longer turns brush


That is the correct belt what you dont see is a tension pulley that when the handle is released pushes on top of that belt giving it the tension it needs. try replacing the other belt, even if it isnt broken it could easily be stretched out ( all bel ... Hoover U6311-930 Power Drive Bagged Upright Vacuum

I installed the Hoover Wind Tunnel Central Vac in my new home. After connecting the wall outlets and successfully turning on the system from the hose control, I discovered there is lots of air flow t


I would recommend checking your wall outlets where the hose plugs in for any type of clog in the tubing. If the vacuum itself ... Vacuums

Hoover wind tunnel vacuum will not turn off


You will have to replace the switch, Takeout the 4 screws on the back of the handle, it will slide off, then from the front, take out the 4 screws that hold the tool compartment on, it will then lift off and you can access the switch. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

My beater bar on Hoover Wind Tunnel 7500 has quit turning. I already replaced the belt. It worked for a while, but now it has stopped and is burning out.


... Hoover WindTunnel Rewind Upright Vacuum Cleaner

Have Hoover Wind Tunnel Sel Propelled vacuum. Had to put on new drive belt. Turn on unit and drive belt slides off the drive spindle.


Look for excessive wear on the unit around the pulleys and their brackets that hold them in place. It sounds like something is just worn out and the belt is either slipping because it is not tight enough or because something is not aligned straight. ... Vacuums

My hoover wind tunnel cyclone will not even turn on why? no noise no lights nothing


The switch is known to go bad i replaced 7 so far this week ... Hoover U5753-900 WindTunnel Bagless Upright Vacuum

My new Hoover Wind Tunnel Upright UH50000 will not turn off unless I unplug it.


First I would be sure the handle was properly installed. Remove the two screws holding the upper handle in place and tap it bacwards to remove it. Set the switch inside to the OFF position. Next set both buttons on the handle to the OFF position and ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

I have a Hoover Wind Tunnel U6437-900. The brush will not turn. I have replaced both of the belts with no success. Any suggestions?


Hello,\015\012\015\012If you've already changed the belts and the machine still won't run, it can really be only a few things. \015\012\015\012The first thing you should check to make sure that the roller brush is good. Yo ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover, model # UH30070 Wind tunnel vacuum Brush won't turn. I do not see how to remove this to replace the brush, and besides it's only about a year old! Why is it already broken? There's no visible evidence on the brush that would make it stop, i.e. string, clogged, etc. Can you help?


... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

I forgot to replace the vacuum cleaning bag in my Hoover Wind Tunnel Supreme Mach 3.3! It overheated and turned off. I spent all afternoon cleaning the dirt out of the inside, filters, etc. It still overheats when used over 1 minute. Do I need to buy a new vacuum?


... Vacuums

Hoover Wind Tunnel 7500 Brush not Turning. I have replaced the Brush and the belt. The problem does not seem to be either to me. I believe might be a missing part. The place were the belt hooks on is a metal pole which never seems to grip the belt well. In fact it seems loose most of the time and slips on the brush, causing the belt to eventually burn up. Could there be a missing plastic or rubber piece meant to hold the belt taught  on the metal pole?


Check the Idler Pulley part Number 43241004 (Item 13 in the IPB)http://64.49.205.183/v/u6451900.pdf ... Vacuums

Hoover wind tunnel cyclonic U5780900 1 year old. brush will not turn. too much slack in vbelt when in carpet position. Belt is good


Well, the V belt is normally fairly slack until the handle is dropped below 45 degrees, which is when the belt tensioner assembly drops into place. If turning the brushroll by hand when the vacuum is in this position fails to rotate the self propel p ... Hoover Vacuums

Hoover wind tunnel turns off after about 5 minutes


... Hoover Vacuums

Wind tunnel t series vacuum won't turn on - Hoover WindTunnel TSeries Bagless Upright Vacuum Cleaner UH70107


I had the same problem and used a tool to clean out the suction tube on my Windtunnel Series T. It was full of junk packed in tight. After cleaning it out there's no more turning off or overheating. It actually works better than when I first got it ( ... Hoover WindTunnel TSeries Bagless Upright Vacuum Cleaner UH70107

Wind tunnel by Hoover, vacuum will not turn off by using switch on upright handle. do not see a way to get to switch. modle no. U5458-900


Follow the cord and look for screws inside the bag compartment at the top. a panel should lift off allowing access to switch and cord. If swtch is melted it must be replaced with special hoover switch kit which has new wire and heavier duty switch. b ... Vacuums

Hoover wind tunnel


Did you check down by the brush roll for a clog in the dirt inlet. And is the brush roll turning freely, if it is being lugged down, it can cause the motor to overheat and the thermo protector will caught it off, until the motor cools down. But if ... Vacuums

Hoover Wind Tunnel ON/Off Switch


Replace the rocker switch inside the handle. Part #28161067, it's about $2.50. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Hoover wind tunnel 2 bagless vacuum not working


Place handle in low position and turn cleaner over so bottom side is up.\015\012Remove the 4 screws in bottom plate and lift off.\015\012Look on the left side of the agitator brush. You should see the belt there. Remove agi ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy