Having problems with your Kirby G5 Bagged Upright Vacuum ?

No power There is no power to my kirby G5. I have checked both safety switches and they seem to be operating properly. I think its the switch but I'm not sure.

Answers :

Where would the reset button be?
Try my troubleshooting guide....
\015\012Hope this helps...
Repair Help & Product Troubleshooting for Kirby G5 Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

No power There is no power to my kirby G5. I have checked both safety switches and they seem to be operating properly. I think its the switch but I'm not sure.

Where would the reset button be? ... Kirby G5 Bagged Upright Vacuum

Hoover Upright Vacuum model U5470-900 - The On/Off switch on the handle does not properly engage the power switch deeper in the handle assembly. It appears to ride over the lower switch and doesn't engage it to operate it. If I play with it, I can get it to maybe turn on the vacuum, but, then the upper handle switch won't turn it off. Our current workaround is to use the power cord for on/off operation.

... Hoover Vacuums

NO POWER My Dyson DCO4 Absolute (purple&lime) won't' switch on. I've checked the plug fuse, wall socket and also filters and hoses on machine all seem fine so think the problem is with the on/off button (maybe loose wire or something) but how do i get to it, is there a special way to remove the green on/off button in order to check the connection? Thankyou in advance for the help i am sure you will be able to provide.

The problem is almost certainly a fatigue break in the flex. These usually happen where the flex enters the handle through the rubber sleeve near the on off switch. You will need to cut about four inches off the wire and reconnect it to the switch. ... Vacuums

Oreck Upright Hi Redev, I'm not sure what model I have (about 6 years old...upright, looks like the one in the picture). I changed the belt (which was torn) and then the next time I used it, it cut off on me. Now if won't turn on at all. (I turn the switch on and off and nothing happens as if it is not plugged in but it is!). I noticed at the top where the power cord enters the handle, it is all frayed. Could the electrical wires have detached? Anything you think I should check before taking it

The cord could be bad and will ahve to be replaced. It would have to have a problem inside the handle or down by the motor. ... Oreck XL2600 Vacuum

Electrolux Epic 6500 SR ...no power to power nozzle. I think it is the switch in the handle because if I use my friend's hose/handle (same model), my power nozzle works fine when I turn on the switch. If you think it is the switch, can I get a part for it?

That's about the best one to narrow down a problem, however, there could also be a break in your hose wiring. Switches, hoses, and hose handle assemblies are all available at your local Aerus Electrolux store. Simply take your entire machine in so ... Vacuums

Motor/Fan does not run. I have removed and taken the top of the canister plastic motor housing apart and tested for power. I have power through the cord to the switch and power from the switch to the two wire terminals. I have not removed the motor. Looks like I will need special tools to take out the motor. The Vac looks almost new. It has been setting for several years. What do you think?

Sorry to read about your problem, I hope this helps you out.Well you can order a new motor at shop vac, check out this link.you dont have to remove to check the motor, just connect power to the motor leads ... Shop Vac QPMH450 Canister WetDry Vacuum

I had the vacuum cleaner question about the canister and the wand/powerhead... the Kenmore Progressive Vacuum canister model 116.25812 and the canister not powering off without unplugging the vacuum. The solution I received that they both run on their own switch so it is normal makes sense. However, is there a power switch on the canister anywhere? The only way for the canister to be turned off is by unplugging it. Any ideas? One would think there would be a switch. I am new to fixya and hope

Hi. On some models, one switch controls all of the power. Your issue, which is no working switch is almost certainly a blown triac on the circuit boar ... Vacuums

The mechanical off/on in the handle is not working with the electrical on/off switch upon removal of the handle you can cut the machine off by hand but after ensuring the the handle is re-placed in the proper position the machine will not turn off so what new handle or is the rocker switch has worn is now to hard for the mechanical switch to operated

Hi there it's SmartAlec from NelsonVacuums.com.au here. You are spot on in your diagnosis however i have fixed heaps of these and i have found no way to tell wether its the ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?

... Vacuums

It won't turn on. I have partially disassembled it and have continuity between the power cord (wide blade) and one of the connectors where the switch assembly snaps in. Also, switch is working fine. There is continuity across it, then no continuity across its connectors when the switch is pressed. Not sure what to try next.

\015\012Please provide the make and model. Thanks. ... Vacuums

I have a Hayden SuperVac 3600, almost 10 years old. The unit still runs, but now when I switch to the power nozzle, it doesn't have power to turn that. I think this happened once before and maybe they replaced a circuit board(?). We took it to a local repairman this time and he says he can fix it temporarily with a new cartridge, but that he won't promise it won't happen again soon.....

The hose has fuseable link inside, generally a 3-7 amp. It is at the wall end underneath the hose cuff. Easy to replace as it crimps in line. If you have a meter you can also test the detachable hose to wall cord for continuity, then check the hose t ... Hayden Industries SuperVac 6000 Central System Vacuum

There is no power...seems like a motor problem. The bag is clean...the mouth is clean the plug us in...NOTHING! I took mouth off and manipulated/pushed in that power press area that engages the motor on the front (not the switch on the back) and NOTHING! Not sure if motor died and/or what to do now. Help. I have had this baby for 15 years.

The front safety switch must be pushed in by either the hose or head (or manually), before the on/off switch will operate. The most common reason for no power is a bad cord. Second most common is worn carbons in the motor, and third is a bad switch. ... Kirby G4 Bagged Upright Vacuum

No power going to hoover have hoover turbo power 3. Plug is sealed but have changed fuse. Have had builders in house using it to renovate bathroom. Do you think it is now passed its sell by date was working until they got it. It dosent even switch on. Am ready to do them an injury as my upstairs is a mess

A Neighbour fixed it ... Hoover Vacuums

Haier 65 pt Dehumidifier. I purchased a new Haier Dehumidifier 2 years ago. I believe this is the third season and it had been working great. Very quite and on humid day's, I have to empty it every 10-12 hrs. Two day's ago it just stopped working, no indicator lights. I plugged it into another outlet to be sure with the same result. I believe it is either the bucket switch or main switch. What do you think and where can I get parts. I live in MA.

HI, this unit has a 12 amp 125v glass tube fuse on the control board. Chances are you blew this fuse. This can happen if the unit is starved for air and ices up. you must take the front of this unit off to access the fuse of this control board. ... Vacuums

Does the trivac 1100 have a fuse? My machine has suddenly stopped.I have checked the fuses in the plugs and also made sure that power is at the wall socket. I can see what loks like a fuse holder in the top of the machine near to the on/off switch but it is very tight so I want to be sure that it is a fuse before unscewing it. Thank you Jim

... Philips Vacuums

Vacuum Power Switch on Handle Doesn't Work

The switch is very cheap. I have the same vacuum. The solution is to stick a thin peice of cardboard under the slide track for the rod in the handle assembly. You will see the rod when you disassemble the handle for the sweeper. Move the on/off switc ... Vacuums

110-220V Dear Sir, I purchased a kirby sentria vacuum cleaner from ebau two weeks ago. I currently resid in the UAE with 220V power. My maid has plugged the vacuum to work with it unaware of the voltage difference, a terrble noise as mentioned came from the cleaner as well as a smell. She unlugged it and stopped t from operating. Can you please let me know how can i assess the damage? If this model has a switch from 110 to 220V IS there a solution with transfromer or motor to make it work? Thank

You may have burnt up the motor field when it was plugged into a 220V power source. But there are drop down transformers you can get to reduce the voltage form 210 to 110. AS Radio Shack or similar store would have them. ... Kirby G4 Bagged Upright Vacuum

Little green machine pro heat pet the collection tank wasn't collection and dirty water was coming out of the bottom. i took it apart, cleaned it up and put a new "duckbill" gasket in. then it quit spraying, but i think i got that working again. now after i spray and get a good foam on the carpet, i switch to suction and it seems very weak. i can see the water moving (trickling) from the head into the hose but it is not reaching the collection tank -- actually, i am not sure where its goin


I've had my Dyson DC14 vacuum cleaner now for approximately 9 months and been very happy with my purchase. However, It is used sparingly maybe twice a week at the very most. The problem is when I try to use the item on my carpet, you have to push really hard to get it to move. It's as though the suction power is far to strong. It certainly doesn't glide as I think it should. It still picks up as usual but I cannot imagine that having to 'force' the machine to move is the normal operating procedu

Thanks for your question!I'm sorry that you haven't received an answer yet.The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:1. the question is unclear, incomplete, or poorly ... Dyson DC14 All floors Bagless Upright Cyclonic Vacuum

The Intelliclean function isn't working properly. The indicators illuminate when I switch Intelliclean off, then on again, but the indicators are not changing (nor the power level) when I vacuum dirty areas. I need to install new filters, could a dirty sensor be the problem?

I was having the same problem with my Intelliclean and I read somewhere on the internet that I should undo the bag, clean in the area where the bag attached to vacuum. When I took bag off, something was stuck there and after I removed it, everything ... Kenmore 31913 Progressive Direct Drive Bagged Upright Vacuum


If reset switch is worn out, how does the unit come apart to replace it? ... Electrolux Vacuums

I have a bosch bagless jet 12 amps/1450 W which I got secondhand. the switch to operate the powerhead (the rug brush) no longer gives me any results. I don't have the right tools to unscrew the plates and look for a belt. I don't think it's a belt problem anyway because I don't hear the powerbrush motor turn on, either.

... Bosch Vacuums

I have a vax cylinder model V-094. Working fine then started to play up. Switch it on and the motor seems to struggle to power up. Kind of wurrs up and down. Was thinking it could be the brushes have worn. Tokk to bits and cleaned her up, took a look at motot and brushes, cleaned them too, back together and still them same problem. Help please, hoover is not old but has done some work really don't want to through away something that can be fixed.

Hi.\015\012\015\012after all you have done I would be pretty confident its the motor thats faulty they are expensive to buy so machine is going to be scrap,\015\012\015\012Sorry.\015\012\015\012 ... Vacuums

Vacuum will not operate switch does not feel as if it is working. Motor is not getting power.

Make sure that both safety switches are engaged (front and bag area). If it is still not working, than could be the cord or ON/OFF switch. How to replace the switch look at detail instructions on our website: ... Kirby G5 Bagged Upright Vacuum

I am looking for a contol board for a miele s143 stick vacuum. The vacuum wont start but when I supply power directly to the motor it spins. I think the switches are OK so I have concluded it is the control board Thanks Don Kenney

You should check the cord and switch's for continuity, the boards are usually pretty reliable, you could check the board for any bad solder joints, at least that would be obvious. ... Vacuums