Having problems with your Kirby Ultimate G Bagged Upright Vacuum ?


Answers :

\015\012DO NOT TRY TO TURN THE KIRBY ON ANYMORE BEFORE YOU GET THIS REPAIRED!!! Your Kirby needs carbon brushes and if you don't already need a new armature, the worn out brushes will destroy the armature that you have. Here is a guide that will help you get down to the carbon brushes to change them...
\015\012It is a guide to replace the power switch, but will give you the step-by-step to get down to the carbon brushes.
\015\012Hope this helps,
You should take it to a kirby shop they will find the problem for free P.S If it is doing that you need new bushings at least you probably can not buy bushings buy them selves you might half to get a new motor which is a little above my budget
Repair Help & Product Troubleshooting for Kirby Ultimate G Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :


Hello,\015\012DO NOT TRY TO TURN THE KIRBY ON ANYMORE BEFORE YOU GET THIS REPAIRED!!! Your Kirby needs carbon brushes and if you don't already need a new armature, the worn out brushes will destroy the armature that you have. Here is a g ... Kirby Ultimate G Bagged Upright Vacuum

DC07 DYSON REPLACEMENT HOSE. HOW DO YOU REMOVE IT FROM THE HANDLE. I have a kenmore whispertone 8540 canister vaccum. The electrical wires (3) to power the beater are embedded in the hose, in a spiral fashion. The yokes that hold the hose on both ends (and attach to the beater on one end and the unit on the other) have no screws or pressure latches; i don't want to use brute force as i may damage the attachment device inside the yoke. If someone can tell me the trick to get these yokes off each

Should be a pry off dot on the underside revealing a screw ... Vacuums

Attachment problem used a new unit w/attachment for 5 minutes...dispensed solution in a powerful triangular fashion. Then the fluid quit dispensing out of the attachment nozle amost like the pump quit working. Primed the unit several times w/ no success. checked for clogs. can't tell if the floor portion is "pumping' or just dribbling solution onto the floor with the trigger. can see no leaks at this point. unit worked for about 5 minutes on apholstery

Make sure everything is filled and secured tightly, if this a new unit it should be something simple ok, also check where machine folds down that the solution hose is not being pinched its right behind the dirty water tank ... Hoover SteamVac F5914-900 SpinScrub Upright Vacuum

The power brush floor rug attachment on my Eureka 6997 A Oxygen Canister Vacuum goes on an off as I use it. I replaced the The power cord from the handle has 2 plug in connections: 1 at the handle / upper wand 1 at the lower wand top of the power brush attachment I replaced the entire wand assembly and it worked great for a year or so and now it's doing the same thing again. I was told to keep the power switch on the handle set to off when connecting the power brush attachment or it will bu

This is from the prongs not making a good connection causing an arch inside the plugg causing what looks like rust on the plugg. I would try snugging up the connection by squeezing the female section to get a better connection on the prongs when it i ... Vacuums

Kenmore canister vacuum model 116-25512506. It has a 2 stage switch on the handle, the vacuum motor will not work, the carpet beater attachment does work, the vacuum motor will not cut on at all with either stage, 1st stage is vac only, 2nd is vac a carpet attachment. Carpet attachment will work, vac does not.

Try to find the reset button. It should be somwhere near the bottom area. It looks like a red dot that you can push inward. If you can press and hold the reset button, it will restart your suction and solve your problem. ... Vacuums

My filter queen majestic quit working. I opened up the unit to see what was wrong and I did not immediately notice anything wrong. Upon furter examination I noticed one of the traces on the printed circuit card was burnt. I used a soldering iron to "bridge the trace and it appeared to fix the problem for a while. Now it has stopped working again, and when I jumper the trace to run the motor it seems to work. Should I just replace the card? Or is there a more serious problem with too much current

I recommend replacing the card. Soldering involves the risk of further damaging the card, so it would be useless anyway. Why waste valuable time?\015\012There is a possibility of the motor overheating, generally due to a blockage in the airfl ... Filter Queen Majestic Canister Vacuum

Self Propel doesn't work! where does the cable attach from handle? How do u do it?

If you haven't already gotten this fixed, simply remove the two screws on the bottom of the handle. Inside is the cable; please make sure to unplug your vaccum first. ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Asking again. Better wording? My lightweight Bissell carpet shampooer is continually spraying cleaning solution. The sucking action works well but can't keep up. This unit does NOT HAVE A HEATER. This is a simple unit. Is there a cable going down the handle from the trigger? ( it feels like that's the way it works. Could the drain be plugged. Also it will only use 1/2 a tank of solution at a time. Then must be filled again

Hi Sue. I understand how frustrating this must be. I'd like to help you with troubleshooting steps, but need more information.\015\012Here's a quick link to contact us: ... Vacuums

Model, 116.c85pbpk0v022 Power-Mate Jr. attachment stopped working, could it be a part within the unit (i.e. the electrical component) or do I need to replace the unit? How do I troubleshoot the electrical connection? No known drop or abuse. Worked last time I used it.

This model frequently stops because, lint, hair, etc. gets caught between the two end pieces of the brush cylinder. Do the following to fix it:1) Remove the two Philips screws from the underside of the unit. 2) The side with the tag will ... Kenmore Vacuums

Shark s3325 stopped working while steaming; thinking the unit had ran out of water I allowed unit to cool before refilling, however unit over flowed with only 700ml water added. When I plugged unit back into outlet it would not turn on (red light was not on) but I hear a click upon plugging in unit, when turning unit power button on and when turning on the handle switch. Please advise how to resolve this problem.

... Euro-Pro S3325 Handheld Steam Vacuum

I have a hoover 3000 i have not used in awhile, and since I removed a large rug, I would like to use it again on my slate floor. HOWEVER, I cannot get it to pick up ANY water in the water recovery unit......it is dry, dry, dry. I have put in a new filter, cleaned the nozzle unit, the scrubber , and reconnected both the recovery unit and the water unit several times, but to no avail. I would like to get a graut attachment a well as replacement part, but since I can't get the basic unit to work, I

Have you made sure the plastic filter cover with the round hole in it that covers the filter is in place ( part # 59177096 ). This piece seems to get lost, and without it there is no pick-up. The other common problem is that the wheel assembly has be ... Hoover Floormate H3000 Upright Wet/Dry Vacuum

The unit does not start when I turn on the switch on the handle. The power nozzel runs, but the vacuum motor does not. The reset button is not popped, there is 110volts to the unit, and I tried flicking the switch inside the unit underneath the filter with no responce.

... Electrolux Centralux Vacuum

Electrical My Kirby Ultimate G won't turn on when it is supposed to, sometimes it will and sometimes it won't ...also I see greenish blue sparks in the machine where the handle attaches to the motor when it is on. As a side note, the shampoo attachment won't make suds anymore.

\015\012PROBLEM: THE KIRBY WILL NOT TURN ON AT ALL\015\012POSSIBLE CAUSES: \015\012\015\012\015\012Please note......The Kirby has TWO safety switches that need to be engaged before it will operate. One is on ... Kirby Ultimate G Bagged Upright Vacuum

I opened the cannister to change the bag and when I closed it the motor switch will not turn on. The second position which turns on the attachment for rugs still comes on. We thougth it was the switch so we ordered the part and it is still doing the same thing. Is there a reset button somewhere inside? The only reset button I see is on the attachment which is working.

It can be a few things. First check the overload protector located on top of the canister. If it has tripped the unit will not run. Push it in to reset. \015\012If that is the problem check the motor safety filter to see if it is clogged and caused t ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

I have an electrolux renaisence vacuum. the brush in the floor attachment turns but I have no suction. When I change to bare floor option on the handle the brush stops turning (correct) but I still have no suction. The lights on the handle showing --floor,carpet, high and low all work.

Sounds like you have a clog, either in the hose or the inlet by the brush roll. ... Vacuums

Armature sparking unit seems to work fine, i can see sparking from armature recently

... Dirt Devil Vision Turbo W/Bonus Upright Vacuum Vacuum

There is a leak above where the portafilter attaches to the machine in the heating unit which occurs when the portafilter is full of coffee and the brewing button is turned on. Is there a gasket that needs replacing inside the heating unit?

They have your cofee maker listed under vacums, lol Same thing right, \015\012Any way here is what I think it is\015\012The valve of hole where the cofee runs thru the filter int yhe pot, is clogged. Pull out the entire piece that allows ... Vacuums

We have a beam Serenity plus home vacuum system and there is no longer sucks. I removed the dirt from the bottom plastic container, but I also notice a sack or bag connected to the unit when I removed the bottom container and inside that sack there appears to be lots of dust. How do I access that and remove that dust without damaging the unit. I don't know how to do that

Hello. Let's begin by getting that dust and dirt out of your permanent filter. To do this, get a big clear plastic bag and pull it up aroung your canister, with the dirt receptacle removed. Then Grasp the sewn in weight inside of the filter and sh ... Beam Industries 2900 Serenity Plus Central System Vacuum

Hello- My Europro EP965 is not shooting out the steam when I activate the switch on the handle. It does not work with the steam iron as well. The indicator lights work and it creating the steam, it is just not letting it out. I believe it is the valve inside, how do I get to it?

Fixya.com is a worthless website.\015\012Thank you ... Euro-Pro S3325 Handheld Steam Vacuum

On the bottom of the Fantom Fury where it states:"The United States and Canada utility patent....". Now go to the far right end of this statement (the end opposite the spring, well I have a crack in the plastic which, when toggled, moves the entire plastic underside of the vacuum to move. In other words, I think I need an entire bottom plastic plate. The cracked area also makes the foot lever (which lowers or locks the vacuum handle) not work as the crack makes it impossible to work. I know

Http://www.geeksquad.fixya.com/ThreadView.aspx?prdid=0&thid=545424\015\012Generic problem for all Vacuums\015\012On the bottom of the\015\012Posted by c ... Vacuums

Vorwerk VK121 vacuum cleaner - smell of burning from housing enclosing motor. How do I get into the housing to inspect the motor? After tilting the bag sideways, there are two screws holding the housing visible, but there seems to be a thrid fixing inside the point where the handle shaft is attached - is the handle simply clipped in place? Thanks

Yes the handle is clipped in place and should come out when the button in front is pushed. Remove the screws you wrote about. After that the puzzle begins. At the bottom of the vacuum where the head is attached, remove the head by pressing the but ... Vacuums

Hi, having problems with my Dyson DC27. It's worked very well for the last few years but recently i can't get the handle to stay attached to the base after using the wand causing the handle to

Hi there, it's Jack at Dyson.I'm surprised to hear that your wand isn't staying attached in use - it's engineered to lock securely to the machine when you replace it after use. Like all of our upright and cylinder vacuums, DC27 has a ... Dyson DC27 Bagless Upright Vacuum

Unit works until we put an attachment on and then it loses sucking power

Which attachment is it? If it is the turbo attachment, it may just need to be cleaned out. Hair (both pet and human) can get wrapped around the brush, gears, and belt, causing the vacuum to lose suction. If you clean the head out, the vacuum shoul ... Electrolux Harmony Canister Vacuum - EL6985 Vacuum

I have the top of the line kenmore canister vacuum. According to the bottom plate the model nimbler is 116.28015700 I was doing the normal vacuuming and the bag full light came on and the vacuum action stropped. There is still power to the mortorized handle and agitator attachment. Is there some type of circuit breaker reset button for the vacuum function? This unit is probably less that two years old and has had very little use

... Kenmore Vacuums

My model F5906-900 --- problem is the brushes have stoped working... I pulled the brush assembly out by holding the two tabs, and all seems clean and the brush assembly rotates easly... onced the brush assembly is removed. What I did notice is the female driver slot (found in the main assembly unit) that drives the brushes seems stuck..Is that normal when the machine is not hooked up to power? How can I get the brushed going??? it is a good machine, but the brush options is important too it's ab

(1) Assure the Brush Control on the hood is NOT set to the OFF position.\015\012(2) Remove the brush assembly by pulling/unlatching it from base on each side.\015\012(3) Does one of the brushes ... Hoover F5906-900 Upright Steam Vacuum