Having problems with your Kirby Ultimate G Bagged Upright Vacuum ?

Don't know how to change belt on the 2001 G limited edition, having problem taking off the brush.


Answers :

Raise the height adjustment to it's highest setting.Turn the belt lifter knob on the brushead counterclockwise till it stops.Remove the brushead,then turn the belt lifter clockwise till it stops,releasing the belt.Turn the brushead around to the back.You will see 2 latches holding the brush plate assembly on.Unlatch those,and remove the brushroll assembly.Remove the brushroll from the plate by bending the tabs at one end to release the brush.Remove the old belt,and slide the new one over the brushroll.If you remove the entire brushroll,install it with the screw heads facing the floor.The ends of the brush roll have different size caps,one end is larger than the other,and one is black,one is white.This is so the brush will only go in one way.
\015\012Re-install brushroll assembly,latch it down.Look thru the opening in the back,and turn the belt lifter till you see the hook pick up the belt.Install the entire brushead on the front of the vacuum,and lock it down,then turn the belt lifter to drop the belt onto the shaft.Lower the height adjustment,and you are ready to go.
Repair Help & Product Troubleshooting for Kirby Ultimate G Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Don't know how to change belt on the 2001 G limited edition, having problem taking off the brush.


Raise the height adjustment to it's highest setting.Turn the belt lifter knob on the brushead counterclockwise till it stops.Remove the brushead,then turn the belt lifter clockwise till it stops,releasing the belt.Turn the brushead around to the back ... Kirby Ultimate G Bagged Upright Vacuum

Last night as I was vacuuming, I noticed that the belt stop indicator light was on. I pulled out the hair that had gotten tangled around the brush in hopes of solving the problem. It didn't change things. I then unscrewed the entire bottom piece to take out the brush roller. I removed hair from the end piece of the brush roller and reattached the belt; however, I cannot figure out where the microchip is supposed to go so that I can reassemble the base piece by screwing it back together. It seems


Not sure what you mean when you refer to a "microchip" but maybe it is a sensor that works with the belt.\015\012Anyway, if you Google the make and model number of your vacuum you can probably get an exploded view or owners manual that might indicate ... Vacuums

Changeing belt I have a Eureka Upright Limited Edition Model 4462D and can not for the life of me find my manual and can not find the screws to take off the plate to change my belt.....help!!!!!


On the top nozzle, there will usually is 2 screws holding the top done. There are slots or holes on each side near the front and the screws or in these holes. Remove them, remove the top cover and then you can get to the brush roll and belt. ... Eureka 2991AVZ Bagless Upright Cyclonic Vacuum

Hoover windtunnel t series belt is loose- roller brush doesnt turn. Its brand new belt is slipping. we bough new belts and putthem on same problem. Can not find solutio in manual. Is the belt supposed to go around the "metal pulley". I know it goes around the little metal motor thing, then thru the guide and around the brush. What is the metal pulley??? Is is the larger round silver thing between the guide and roller?


I also have a loose belt and have bought additional belts but have the same problem. I put the it around the metal rotor and around the brush roller a shown by he Hoover video, and it is loose. ... Hoover S3765-040 WindTunnel Bagless Canister Vacuum

How is the V-belt tension adjusted (Hoover Model U6439-900)or how do I know if the tension is correct? There seems to be a lot of "play" in the belt and I'm wondering if that is the reason the brush roll only turns as the wheels turn, regardless of the carpet height setting. And yes, the brush roll is set for carpet, not hard floor. Or is the cause of the problem something other than the V-belt? A new flat belt was installed when the machine was professionally serviced so I assume (?) that was a


The V-Belt is not adjustable. There are two ways the belt has no tension: (1) when the handle is upright, a mechanical lever takes the drive tension off the belt, and (2) the brush roll lever setting you described. The upper handle would have to be ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

The hose works great, but the head of the vaccuum does not pick up anything !!! I checked every opening that may have been clogged, but nothing came up. When I hold my hand under the brush/roller, it seems to be putting out more air than intaking air. Particles "dance" on the carpet, but don't get "sucked up" into the vaccuum ? I have had the vaccuum only 1 year, so the brushes should not be a problem. I changed the bag, and checked the belt. The belt and brushes seem to be OK. ?


Hi there,Uprights are notorious for debris forming clogs when changing direction. The 90 degree turn where the base suction goes up. Have a closer look . You may need to pull the base plate off to access the blockage.Best reg ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

How to take apart the Hoover U6437-900 to change the belt and clean it. I have the belts and I have removed several screws. It looks like the knobs for the wheel carpet height and carpet to floor selection are the problems but I can not figure out how to remove the knobs. Besides, I am not certain if this is the problem. Do you have the instructions? Thanks


HERE IS THE MANUAL > http://hoover.com/file/500/ ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

Modle u5095 hover belt problem and I don't know how to acess the belt to change


Here is a Link to one of my Tips:www.fixya.com/support/r6311178-vacuum_brush_bar_not_spinningIf you need more help, just let me know. ... Hoover Vacuums

The belt is intact but the aggitator doesn't spin anymore. Had a horrible rubber smell, went to change belt. Not the problem. Anyone know what could be wrong? Dirt Devil bagless w/dirt indicator


It could also be a bearing problem in the roller brush. Take the belt\015\012off of the roller brush and see if the brush spins freely, if not, remove the\015\012roller brush and check both ends to see if one end is stuck. If so you ... Vacuums

I have hoover mdl U6459-900 and the brush will not rotate even though the main pulley belt is rotating. i have changed booh belts and this did not solve the problem. the suction on the unit seems ok. thanks??


Sound like you need tear down and find whats jamed in it to stop it from turning like string ore hair ... Hoover U6437-900 / U6439-900 Windtunnel Bagged Upright Vacuum

I just changed both belts and the brush does not spin. this is an ongoing problem with this machine.


Check the bearings at the end of the brush bar are not seized up ... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

We have the Kirby G six 2001 Limited edition vacuum and we cannot get the belt to hook on to the roller brush.


... Kirby G6 Bagged Upright Vacuum

I have a Fantom 500 DX and it seems that it doesn't pick up anything anymore. It looks like machine is working well, but it doen't pick up. I would like to take to the repair guy, but I don't know where to find one. Machine is good, it might need jsu some maintenance. Please advise. I live on Long Island, NY. PLease advise. I changed the belt about 6 months ago, but all other parts are original.


The type of bagless that has sharp turns in the hose and plastic parts are easy to become stopped up. You have to follow the path of the air flow to find the blockage. ... Fantom Vacums FM760 Twister 500DX Bagless Upright Cyclonic Vacuum

How do I change the belt on my Kirby G 2000 Limited Edition?


Lift the head two pedal clicks off the carpet.Lift the headlight and you will find a silver thumb dial to remove the carpet head. At the front of the head there is a square dial which you must rotate to release the belt if not broken. Rotate th ... Windsor SR12 Sensor Bagged Upright Vacuum

I have a proheat carpet cleaner model 3 7901. the problem is the brush on the bottom of the machine plus the two end parts and the belt came out. i put everything back but they popped out, they are not staying in place. what am i doing wrong or what do i have to take out to get everything in place correctly?


Hi\015\012\015\0121. You’ll need to follow this procedure to assemble your unit back together.\015\0122. Make sure the foot pedal is in the proper position.\015\0123. The SmartMix should be properly loaded into the main ... Bissell 7901-1 ProHeat Scotchgard Upright Wet/Dry Vacuum

It is making a racket when i turn it on. I took the brush off and cleaned it it is not the belt i don't know how to take the cover off the top front so i can look near the motor can you help please. [email protected] .com Thank you Staci Bishop


These units have two screws that hold the "hood" in place. With the belt/brush roll cover off look on the underside for the heads of these screws. Once these are removed the top should come off. ... Hoover U5096-930 Bagged Upright Vacuum

I need to know if roller brush is supposed to turn it doesn't if it needs a belt pleasr show diagram or video how to change


... Bissell 7920 ProHeat Pro-Tech Upright Wet/Dry Vacuum

How do you take the brush off to change the belt?


The link below is a video on how to change the belt.\015\012http://www.bissell.com/VideoRating.aspx?id=1555 ... Bissell 7950 ProHeat Upright Wet/Dry Vacuum

I do not know how to get to belt on eureka 4335 to change it, what screws do I take out and where


Here is a link to the belt you need and to the manual which has instructions:Eureka 4335 Belt ... Bissell Flip-It Select Hard Floor Cleaner - Volcanic Satin

Brushes don't turn. Don't know how to take bottom off. This is an almost new machine. Wonder if it has to do with the change in air flow from when you use the tube and then go back to regular. I feel like it is quite simple but can't figure it out. Thanks so much Judy


Hi Judy. If its new then I bet you its to do with the clutch. \015\012\015\012See the knob on the bottom of the machine. You use this to switch the Brushbar off and on. You can switch it off so that the brushbar wouldnt scratch a wooden f ... Dyson DC14 All floors Bagless Upright Cyclonic Vacuum

I own a Bissell Proheat Pet Model 8910. After just a few uses and changing both the brush and pump belts (trying to resolve problem) carpet doesn't get wet any longer. Carpet solution comes out normally but the water barly leaves the section of the tank I fill water into, resulting in carpet recieving to much solution and not enough water. Any advice?


... Bissell 8910 ProHeat Clear View Upright Vacuum

I have a Hoover Windtunnel U 6439-900. The agitator brush will not turn. I installed 2 new belts, # 38528034, and # 38528-035 There is so much slack in belt # 3852034 (brush drive) that it cannot grip the brush. There does not seem to be any adjustment to take up the slack. I've put in new belts twice now & cannot get brush to rotate or tighten the belt to the brush.


... Hoover U6630-900 WindTunnel Bagless Upright Vacuum

We own a dirt devil model 088600, and are experiencing a problem with the belt wearing away a section between where the belt connects to the brushes and the motor. There is a lot of plastic/rubber residue coming out from the vacuum. We have tried new belts only to find the same problem occurs. I noticed that the source of the dust is coming from the section between the brushes and motor, where there appears to be a section that is misshapen and melted. I looked up the schematic online and can't


If you are certain that the belt is seated correctly and the beater bar is nested in its holder and the cover of the assembly has been properly installed and you still see a contact area between the belt and cover, you should either: return the vac ... Dirt Devil Vacuums

Hoover Wind Tunnel 7500 Brush not Turning. I have replaced the Brush and the belt. The problem does not seem to be either to me. I believe might be a missing part. The place were the belt hooks on is a metal pole which never seems to grip the belt well. In fact it seems loose most of the time and slips on the brush, causing the belt to eventually burn up. Could there be a missing plastic or rubber piece meant to hold the belt taught  on the metal pole?


Check the Idler Pulley part Number 43241004 (Item 13 in the IPB)http://64.49.205.183/v/u6451900.pdf ... Vacuums

I have a VAX V12 vacuum cleaner which suddenly stopped. The smell indicated Carbon Brush Problems. I contacted a service agent who told me that it was not possible to change the Carbon Brushes brushes on this model and they would need to change the Motor Unit.. To me this sounds very unlikely. Two questions please. Is it possible to change the Carbon Brushes and how do I get the cabinet apart which looks very difficult. I am well qualified electrically to do this job. Regards James Beech


... Vacuums
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy