Having problems with your Kirby Vacuums ?

Hi! I'm interested in purchasing a G3 model ; however , the seller says that the machine was working perfectly and then when switching power on a while later , the machine was " dead " . Other than the brushes , power switch or lead , is there perhaps a fuse at all which could possibly have burned out ? Thanks .

Answers :

Greetings from GoVacuum.com,

Unfortunately there is no fuse on a Kirby Generation model. In my 10 years of repairing Kirby's as well as other vacuums, I will tell you that 9 times out of 10, when a Kirby Generation doesn't turn on, it's the cord that needs to be replaced. This is by far the most common problem that we see on Kirby repairs.
The Kirby motor is very well built, and usually has a life of 30+ years (G3 is about 12-15 years now). The only other problem it could be on the Kirby would be carbon brushes, or the switch assembly.

I would first try testing the power cord, I think this will solve the problem for you. To test a cord on a Kirby Generation (all Generation models are the same machines, just different colors) first follow where the cord goes into the Kirby at the bottom. To access this cover easier, first remove the "boot" at the bottom of the outer bag. This is the plastic part at the bottom of the outer bag that connects onto the Kirby. You will see that there is a plastic cover over the cord. You will need to remove the screw that holds this cover on.

Now after you have removed the cover, pull the plug out of the machine. Once you have the cord disconnected from the machine, you can now test it to see if there is a short somewhere in the cord. You will need to purchase an inexpensive continuity tester from Home Depot, Radio Shack, or most other electronic stores. This will tell you if there is power running through the cord, or if the cord is bad. With the continuity tester, plug the cord into the wall outlet, then put the positive, and negative testing rods into the female end of the cord that plugs into the machine. You will then be able to tell if the cord has continuity going through it. The tester will indicate if there's continuity or not.

The picture here shows that the cord is good. If your tester does not light up, or indicate that there is continuity, you'll simply just need to purchase a new cord. As I stated earlier, this is the most common reason that a Kirby won't turn on.

If however your cord tests OK, this indicates that the machine either needs a new motor (or carbon brushes in the motor) or it needs a new switch.

Please feel free to email me if you'd like instructions on how to diagnosis the switch or carbon brushes, or if you need to purchase a cord for your G3. Also I can send you a parts diagram of the Kirby should you ever need any other part for it. I have all parts for Kirby in stock, and we are the cheapest price online.

Chris Jones
[email protected]
Repair Help & Product Troubleshooting for Kirby Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Hi! I'm interested in purchasing a G3 model ; however , the seller says that the machine was working perfectly and then when switching power on a while later , the machine was " dead " . Other than the brushes , power switch or lead , is there perhaps a fuse at all which could possibly have burned out ? Thanks .

Greetings from GoVacuum.com,Unfortunately there is no fuse on a Kirby Generation model. In my 10 years of repairing Kirby's as well as other vacuums, I will tell you that 9 times out of 10, when a Kirby Generation doesn't turn on, it's t ... Kirby Vacuums

Does the trivac 1100 have a fuse? My machine has suddenly stopped.I have checked the fuses in the plugs and also made sure that power is at the wall socket. I can see what loks like a fuse holder in the top of the machine near to the on/off switch but it is very tight so I want to be sure that it is a fuse before unscewing it. Thank you Jim

... Philips Vacuums

Faithful Sebo X1 upright, about 12 years old, stopped working today. I replaced old with new dust bag, checked all dust paths were clear, checked main brush was clear/clean, and drive spindle rotated OK with fingers. When power switched on, the two red indicators briefly flash on then off, but nothing more happens, motor does not start - even with power reaching machine. Tried removing all consumables, refitting and turning on a few times to reset, no joy. Removed base cover, both belts were i

At 12 years, this vacuum has had a good long life. I suspect the motor is shot, but it could be due to faulty wiring and connections. A bad switch, break in the power cord, and worn brushes in the motor are other causes.\015\012I recommend ta ... Sebo Automatic X1 Bagged Upright Vacuum

My dyson will not switch on , the last time I used it the power faded in and out a couple of times I wiggled the lead and it continued to work. However today it will not power up, I have changed the fuse just in case

Hi from uk the symptoms you described is a classic fault with where power wire has broken within the main cable usually at pint where it enters the vac ? hence wriggling wire temporarily makes contact are you sure the wires in plug are ... Dyson DC07 Bagless Upright Cyclonic Vacuum

Oreck model BB870-AS - I was vaccuming when the vac shut off. The motor just spooled down and nothing more since. I have opened the case. Have power at the switch, and to the motor, but can't get a voltage reading to the common lead at the motor. Is there a fusible link, or something similar in that lead that might have burned out? Thanks!

... Oreck Vacuums

My brushes do not turn on my power glide pet vacuum cleaner after I accidentally sucked up the hem of a curtain. I switched off the machine then removed the hem. Now when the vaccuum cleaner is turned

... Electrolux Vacuums

NO POWER My Dyson DCO4 Absolute (purple&lime) won't' switch on. I've checked the plug fuse, wall socket and also filters and hoses on machine all seem fine so think the problem is with the on/off button (maybe loose wire or something) but how do i get to it, is there a special way to remove the green on/off button in order to check the connection? Thankyou in advance for the help i am sure you will be able to provide.

The problem is almost certainly a fatigue break in the flex. These usually happen where the flex enters the handle through the rubber sleeve near the on off switch. You will need to cut about four inches off the wire and reconnect it to the switch. ... Vacuums

When motor is switched on, power supply tripped and fuse burned.

Sounds like field has grounded, you will need to get a Kirby engineer ... Kirby G4 Bagged Upright Vacuum

Replaced Oreck power switch. 2 black leads and 1 white lead for switch. Posts marked 1, 2, and 3. 2 black wires to switch powers on. Connect white wire and breaker trips. Where does the white wire go?

Both black go to the switch. Power in - black to switch / white to white from motor. From motor - black to switch / white to white from power cord The black wire from the power hooks to ... Vacuums

Can you send me a La Cimbali M22 Premium espresso machine power switch wiring diagram? I have a machine without a power switch. The switch is on order but I still have to connect the 10 loose wires. Thanks, Terry...

... Vacuums

The power brush floor rug attachment on my Eureka 6997 A Oxygen Canister Vacuum goes on an off as I use it. I replaced the The power cord from the handle has 2 plug in connections: 1 at the handle / upper wand 1 at the lower wand top of the power brush attachment I replaced the entire wand assembly and it worked great for a year or so and now it's doing the same thing again. I was told to keep the power switch on the handle set to off when connecting the power brush attachment or it will bu

This is from the prongs not making a good connection causing an arch inside the plugg causing what looks like rust on the plugg. I would try snugging up the connection by squeezing the female section to get a better connection on the prongs when it i ... Vacuums

My model F5906-900 --- problem is the brushes have stoped working... I pulled the brush assembly out by holding the two tabs, and all seems clean and the brush assembly rotates easly... onced the brush assembly is removed. What I did notice is the female driver slot (found in the main assembly unit) that drives the brushes seems stuck..Is that normal when the machine is not hooked up to power? How can I get the brushed going??? it is a good machine, but the brush options is important too it's ab

(1) Assure the Brush Control on the hood is NOT set to the OFF position.\015\012(2) Remove the brush assembly by pulling/unlatching it from base on each side.\015\012(3) Does one of the brushes ... Hoover F5906-900 Upright Steam Vacuum

Electrolux vacuum brush not turning problem: was vacuuming and rug got caught auto shut off kicked off power to brush. instead of hitting red button to restart brush I disconnected brush to vacuum some hair in Conner. after i reconnected the brush and hit the red button but no power to brush. Light won't even switch on. Hope you can help

Under the vacuum, there is a guard.\012remove the guard , either by 2 screws or by 2 clips.\012there is a belt under the guard.\012that is connected to the brush.\012the belt need to be replaced. ... Vacuums

My dyson dc animal's brush is not spinning. The machine smells like burning rubber. I believe the clutch has gone out but the machine also only sucks from the top of the hose in the handle. I am wondering if the machine is not locking properly which is causing the brush to not need to spin. If this is the problem how do i fix this problem.

... Dyson DC14 Animal Bagless Upright Cyclonic Vacuum

Dc15 fuse The roller brushes on my dc15 stopped working..I checked the obvious and then noticed that the 2 amp fuse was blown on the circuit board . I've replaced it with the same type bought from Maplins but it keeps blowing .. I tested the yellow an blue wires leading from the circuit board to the roller brush head and the are in tact and I can run a current through them ... Any thoughts from anyone .? Your help would be. Appreciated thanks Lee

Hi Lee,I'm sorry to hear you're having difficulty with your DC15. If you'd like some help, please give us a call on 0800 298 0298 - we may be able to resolve the issue with some troubleshooting over the phone.Best wishes,Jack ... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

I have a Hoover U3330 001 upright vacuum, while using it today the power suddenly cut out and it stopped working. I have replaced the fuse with a new and tested fuse, but the machine will still not power up. please can you help?

... Hoover Vacuums

Just purchased this Dyson dc24 today. brush doesn't spin after gettin tangled in a cord. removed the cord from the brush OK. I have several times: removed the brush and replaced it OK. pushed the red button by the brush. pressed the brush power switch.

When you removed the brush roller dod you examine the end of the actual roller that is opposite from the removal opening. There is a gear that the roller fits over that may have gotten stripped when it became tangled. Check that the gear has not roun ... Dyson Ball DC24 Bagless Upright Vacuum

The brushes spin very, very slowly and stop altogether sometimes - like they just don't have any power behind them.I've cleaned the brushes and also turned it on without the brushes inside to see if the female plug that the brushes go into turns - it does, but not very fast. My husband said he thought he smelled something - like burning. Is there a way to take the underside cover off and clean something?

... Hoover SteamVac F5914-900 SpinScrub Upright Vacuum

I have an Easy-Flo central vac unit. The handle on the electric hose has a switch on the handle. With the switch on ''O'' in the center, it's off. On the left, is the ''I'' position. The vacuum runs but the power brush doesn't. On the right is the ''II'' position. The switch won't flip that way. It feels stuck. It feels as if there is something underneath of it that won't let it push that direction. I have the switch out of the handle, but I can't seem to get the actual black casing around the

Switches are not usually designed to be dissembled.I would strongly suggest that you dont take the switch apart. you are better off getting a new one. then if you feel like it you can take the old switch apart and if it dosnt work you still hav ... Vacuums

My Bissell Model 3760-4 is not working properly. The belt has been replaced (and checked 3 times), but the brush bar does not move when the brush motor button is on. The little metal turning piece that turns the belt is turnable with one's finger when the belt is off, but when we put it all back together and turn on the vacuum, the brush bar does not go around and the burning belt smell returns. The portable part of the machine works properly. It's the brush bar. It has been cleared of hair, etc

... Bissell Lift-Off(R) Revolution(R) Turbo Upright Vacuum

I have the bissell power force bagged upright vacuum and the brush is not turning, I have replaced the belt but the brush will not move but the metal piece that is hooked to the motor that spins the belt and brush is turning but the brush won't, and the belt starts to burn

Sounds like your brush roll is seized. Remove the brush roll (see picture) and make both of the end caps spin freely. If not, replace it and you should be set. *An example of a brush roll* ... Bissell 3522 PowerForce Bagged Upright Vacuum

No power to vacuum - internal fuse? switch?

... Dirt Devil Featherlite Bagless Upright Vacuum

Purchased a new, portable, vacuum this date. 4/24/08 at Gottschalk's. Got it home, unpacked it and installed attachments. plugged into a power source, and depressed the power switch, machine did not come on, used three different power sources to no avail. advise--- Reply to [email protected] asap

Being under warranty, I would take it back for an exchange. You don't want something brand new and it is dead on arrival. Either that or take it to a warranty shop for repair. You mess with it and that avoids the warranty. ... Vacuums

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?

... Vacuums

My eureka 5902 4D bagless uprights roller brush stopped spinning. The belt is ok. This model has a sliding switch for roller speed. The brush should spin when you release the handle via the foot release. Bad brush motor or is there a fuse involved?

The same thing happened to me about a year ago with this very model. \015\012The issue on mine was a small, copper-colored metal wheel that attaches to the end of the brush roller. You'll need to remove the top cover (there are several screws). ... Eureka Smartvac 4870 Bagged Upright Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0749 seconds