Suggested Questions/Answers :

We have a Kenmore canister vacuum cleaner 25614504. It has in intermittant light and power flicker in the power mate unit as it is moving over the floor. This behavior can be simulated by jiggling the power cord where it eners the power mate. I do not know how to enter the power mate to see if there is a loose wire.


... Kenmore 28614 Canister Vacuum

No power. I was getting intermittent power with my miele s558 midsize canister, but it was predicated with me fiddling with the retractable cord to get it to come on and then not move the canister while I was vacuuming. Now I can get no power. I have taken it apart and can see no issues with connectors, cord, casings, etc. It all looks fine. It is about 5 years old and I have had no problems with it.


... Miele S558 Red Velvet Bagged Canister Vacuum

The power goes off and on when using my vacuum. When I push my vacuum forward, intermittently it loses power.


Almost certainly there's a broken wire within the electric flex. This usually happens where there's most bending and pulling - that is, where the flex enters the machine or where it enters the plug. You'll need to get someone to either shorten the fl ... Vacuums

My electrolux Epic 6500 power nozzle Model N109J will not work. It had an intermittent short which I thought I fixed (some of the insulation on the wires were pinched). I fixed the wires and it worked intermittently for an hour then shut down completely. Could the reset switch have a short? When I press the switch nothing happens.


The switch is definitely a possibility, but other problems can also cause this.\015\012Bad switch, needs replaced.\015\012Broken wiring in power nozzle, wands, hose, or canister.\015\012Bad PN motor.\015\012\015\012I str ... Electrolux Epic 6500 Vacuum

Power intermittent: when cable is touched power returns


You have a broken power cord. Hoover is notorious for power cords. I'm speaking from personal experience. Replace/have the power cord replaced. ... Vacuums

HI, I have a Kenmore 25813 and it seems like there is an intermittent short. When I have the extension wand on and the power floor attachment on, when it rotate the wand the light cuts out and so does the power floor attachment, when I twist it back it comes on again. I don't have this problem if I remove the wand and just use the crevice tool with the hose. Any idea where the short might be and can I fix it myself? Thanks. Gary


This is common you may have a short in the contacts from the handle to the wand or a break in the cord that goes into the powerhead ... Kenmore 25812 / 25813 Progressive Bagged Canister Vacuum

Intermittent Power to Powermate


... Kenmore Vacuums

Power nozzle works intermittently


The pin connection from the lower handle tube to the power nozzle are not making good contact. It is new, so i would have warranty service performed. ... Vacuums

Blue Moon Miele power head stops intermittantly


It is not a solid short. This is caused by static arcing in the wand and in the connectors from base to hose. I was able to fix mine by smearing some dialectric grease on all electrical parts in the wand(especially by the led switch) and in the three ... Miele Blue Moon Bagged Canister Vacuum

Kirby G5 intermittent power


I would say that it is a short in the power cord. \015\012\015\012Try my troubleshooting guide. It helps with do-it-yourself Kirby repairs. You'll also find links to directions, parts (cords too!!) and free repair guides! ... Kirby G5 Bagged Upright Vacuum

Power head and wand connection is intermittent.


If there is a rubber bumper on your power head you must slip it off before the two halves will separate. ... Kenmore 25512/ 25513 Progressive Canister Vacuum

Power head just quits intermittently, red lights flash on


... Vacuums

Beam powerhead looses power intermittently


... Beam Industries Vacuums

Intermittent Power brush


Dirt gets inside and causes an intermitten problem on the hose where it connects with the canister there is a plastic cover where the three pins stick out. on the cover are two tabs on either side. press both tabs together and CAREFULLY pull cover of ... Kenmore 22812 Bagged Canister Vacuum

The power head has developed an intermittent, but frequent, electrical short. Is there an easy way to assess where? Or is this a matter for a repair shop.


Greetings,\015\012\015\012A majority of the time when this happens, it's caused by the hose having a short in it. You'll need to first identify what the source of the short it. To do this, turn the power brush on, and then swivel the h ... Kenmore 23812 Progressive PowerMate Bagged Canister Vacuum

My electrolux sidekick, model 1562 makes a nasty screeching sound.It happens as soon as it is powered on,the noise then gets intermittent after qa few minutes and then goes away.This cycle is repeated evry time i use it.I have checked it for binding and obstructions and oiled the motor.I think it's the roller brush but oiling it didn't seem to help


... Electrolux Vacuums

Dc15 power bar problems -intermittently cut out like loose wire??


... Dyson DC15 All Floors - The Ball Bagless Upright Cyclonic Vacuum

SubBrand name 'Exmork', 5 Kw Sine wave inverter Intermittently, breaks into a spurious mode which causes it to draw excessive current while the output waveform becomes seriously corrupted with severe transient spikes close to the crossover point. We have available oscilloscope images showing the problem graphically. We have four of these inverters out in the field, and they all exhibit the problem from time to time. The fault has precipitated failures in the Power-board module in two units


Had similar problems with my inverters a while back tried to sort it out myself all to no avail. Eventually found out it was a problem from the manufacturers and all that were produced had the same fault. Had to change my brand to Su-Kam inverters. I ... Vacuums

My Riccar 1700 will intermittently lose power while vacuuming. I have had the vacuum for 4 years and this is the second time that I have had this problem. The first time the authorized repairperson said the problem was a dirty hepa filter. The second time, the repairperson put on a "pig-tail"(?) and said that he did not have a shut-down problem when he tested the vacuum in the store. I just picked it up from the store today, brought it home and the same problem occurred within minutes.


... Riccar RC1100 Compact Vacuum

Intermittent power (turns off at random while operating) and sometimes appears related to the chord and sometimes not


... Miele S558 Red Velvet Bagged Canister Vacuum

I HAVE YOUR UNIT MODEL CD1493. THE POWER CORD PLUGS INTO THE BACK OF THE UNIT OK,BUT, IT A VERY WIGGLY CONNECTION. AS A RESULT THE UNIT OPERATES VERY INTERMITTENTLY. WHAT CAN I DO.


Hi,\012Try to spred the pins slightly so that they hold the plug more tightly...otherwise the only thing to do is to try and buy a replacement cord...\012\012heatman101 ... Vacuums

We have a Kenmore canister vacuum cleaner. the carpet cleaning attachment, I think is called the power mate has a beater that is intermittently working now


Contrary to your advice, the nozzel cannot be connected directly to the powerhead--the female openings are set closer together in the nozzel than the male plugs in the powerhead. ... Kenmore 23812 Progressive PowerMate Bagged Canister Vacuum

The vacuum will loose power intermittently during use and want re-start


A very common problem i have found, often caused by over heating, check for any blockages as well as cleaning or replacing the filters, if the problem continues you may need to replace the motor. Good Luck. ... Dyson DC07 Animal Bagless Upright Cyclonic Vacuum

I have an Electrolux Epic 6500 SR vacuum and the hose end with the handle is separating. Power nozzle losing contact intermittently. Is this piece replaceable or repairable?


It is replaceable. Just take it to the nearest Aerus Electrolux store and the service tech will take care of it for you.\015\012Go to the following site and follow instructions to find the stores nearest you. ... Electrolux Epic 6500 Vacuum

Intermittent power the vacum will turn on then quits running - will start again - then quit again


... Fantom Vacums FM760 Twister 500DX Bagless Upright Cyclonic Vacuum