Having problems with your Sanyo Vacuums ?

Old Sanyo 1500 watt "Power Control" vacuum cleaner. I need to remove the plastic covers that are attached to the on/off switch and the power cord recoil. This will allow me to remove the retaining screws for the upper motor cowling. The motor and wiring is clogged with wood dust and I want to blow the dust out using compressed air.


Answers :

Repair Help & Product Troubleshooting for Sanyo Vacuums

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Old Sanyo 1500 watt "Power Control" vacuum cleaner. I need to remove the plastic covers that are attached to the on/off switch and the power cord recoil. This will allow me to remove the retaining screws for the upper motor cowling. The motor and wiring is clogged with wood dust and I want to blow the dust out using compressed air.


... Sanyo Vacuums

Samsung Quiet Storm Canister Vacuum VAC-9049 The motor will not run. Power is on to the motorized rug tool. How can I remove the upper housing to get access to the motor? I have removed the six visible screws, but the housing is restrained at the rear. I suspect there are additional screws under the power switch and cord retractor assembly, but I cannot remove that either. HELP!


Hi Daltm,\015\012Thank you for contacting Fixya. This is Anil.\015\012I understand that you need assistance n opening the Samsung Vaccum VAC-9049 motor. I will be glad to help you with it.\015\012Please go through ... Samsung Quiet Storm 9048R Bagged Canister Vacuum

Motor/Fan does not run. I have removed and taken the top of the canister plastic motor housing apart and tested for power. I have power through the cord to the switch and power from the switch to the two wire terminals. I have not removed the motor. Looks like I will need special tools to take out the motor. The Vac looks almost new. It has been setting for several years. What do you think?


Sorry to read about your problem, I hope this helps you out.Well you can order a new motor at shop vac, check out this link.you dont have to remove to check the motor, just connect power to the motor leads ... Shop Vac QPMH450 Canister WetDry Vacuum

The removable filter at the front is cleaned regularly, and is not clogged. However, the machine appears to be suffering from being clogged by dust, as it has started to make a high pitched noise, and I fear it may burn out. I can see some dust inside the front panel but cannot see how to remove the front to clean it out. (NB. I have located two screws - one on either side - but cannot see how to proceed further.) Please help! Thank you.


\015\012\015\012Hi,Here\015\012is a tip that I wrote about my Bissel but I bet you have the same\015\012problem and the hose is clogged...Bissell Bagless Upright\015\012 ... Vacuums

Faithful Sebo X1 upright, about 12 years old, stopped working today. I replaced old with new dust bag, checked all dust paths were clear, checked main brush was clear/clean, and drive spindle rotated OK with fingers. When power switched on, the two red indicators briefly flash on then off, but nothing more happens, motor does not start - even with power reaching machine. Tried removing all consumables, refitting and turning on a few times to reset, no joy. Removed base cover, both belts were i


At 12 years, this vacuum has had a good long life. I suspect the motor is shot, but it could be due to faulty wiring and connections. A bad switch, break in the power cord, and worn brushes in the motor are other causes.\015\012I recommend ta ... Sebo Automatic X1 Bagged Upright Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?


... Vacuums

The brush wouldn't work when the selector switch was in carpet mode. Took the power head apart and removed the motor. Everything o.k. in the power head. Checked and found that the neutural wire had pulled out of the connector, the connector was never crimped at the factory. What a day! Took 2 hours and a large pizza to get it done. Neutral wire was in the hose just below the handle. Reconnected the wire and crimped it, put everything back together. It works!!!!


Great. ... Kenmore Vacuums

My electrolux ambassador power wand quit working. I replaced the switch that shuts it off when the roller stops, but it wasn't the problem. The on/off switch is fine, the motor is fine. We have traced the problem to the wires inside the canister by opening the inside cover to the bag container. We see the power cords going into the canister but we're not able to get to anything. We can't find any screws to undo that would open it up in order to follow the wires deep into the canister. We've bypa


... Electrolux Vacuums

I have the Miele S7280...the one without the clog hatch on the back. I took the bag cover off, then continued the remove the screws and cover underneath it to detatch the top from the bottom. Found the clog and cleaned it out. Heres the problem...now the power nozzle light comes on and the vacuum "on" is lite up red, but it will not come on. Checked the filters and the bag. It certaintly seems like the top and bottom are meeting up to latch into each other, but I have no power. Help!!


... Miele S7210 Bagged Upright Vacuum

How do I access the motor to my eureka capture? It has no suction at all but turns on just fine..filters are cleaned and there are no clogs or leaks on the hose....im thinking there must be something stuck in the motor possibly but there are soo many screws that im having trouble removing them all....whats the best way to access the motor to check it??


... Eureka Capture Upright Vacuum Vacuum

My vax power 8, 2200 watts 300 air watts 4L capacity upright Hoover is brand new, I emptied out the dust/dirt collecter and cleaned the motor filter yesterday for the first time, i switched it on and all fine, the brush is spinning and the hose is sucking, put the Hoover to work it's fine for about 30 seconds then then suction stops and its dead it won't collect no more, so switched off taken apart again and the motor filter is blocked and full of dust, so I unblocked it, do the same process aga


I had the same problem. It looks like the seal on the lid on the bottom of the cylinder has fallen out when it was emptied. There is no longer a proper vacuum being created so you don't get the cyclone effect and the dirt doesn't collect where its su ... Vacuums

DC07 DYSON REPLACEMENT HOSE. HOW DO YOU REMOVE IT FROM THE HANDLE. I have a kenmore whispertone 8540 canister vaccum. The electrical wires (3) to power the beater are embedded in the hose, in a spiral fashion. The yokes that hold the hose on both ends (and attach to the beater on one end and the unit on the other) have no screws or pressure latches; i don't want to use brute force as i may damage the attachment device inside the yoke. If someone can tell me the trick to get these yokes off each


Should be a pry off dot on the underside revealing a screw ... Vacuums

Kenmore 3.9 with power-mate Model 116 2839581. Can't locate screws to allow cover removal for access to motor


You have to take off the top of the power nozzel that has the light lense. There are two pressure locks,one on each side. Use a screw driver to release. You will see the screws.Take the two screws out and on some models, there are two pressure locks ... Kenmore 22313 Bagged Canister Vacuum

Dyson DC07 My DC07 cuts out after 5 mins and I want to replace the thermal cutout. I have cleaned it thoroughly, including the cyclones but it still cuts out. How does the plastic moulding around the motor dismantle? I have started by removing the 4 torx screws but the upper grey housing does not want to detach and I am worried about breaking the plastic. Appreciate any advice.


Try this page: -http://www.fixya.com/support/t192124-overheating_dyson_dc07Regards Gualo ... Dyson DC07 Bagless Upright Cyclonic Vacuum

My Electrolux Regency Series upright vacuum brush motor does not activate. Cleaned the brush and press reset to no avail. Opened handle switch assembly and checked each wire attached to all three switch settings. Tried disassembling brush assembly but could not pry open after removing all screws.


... Electrolux Vacuums

I have a Necchi LYdia 3 machine type 544 The motor was overheating and I removed the bottom cover and examined the motor .It looked fine and ran well. It worked OK for a time and then got hot.I was able to partially remove the motor for inspection.I found that the cooling impeller was not secured to the shaft,I tightened the set screws and reinstalled the motor. In process of getting the drive belt back on I turned the wheel that extends out of the case to index the screw that attaches the bobb


Good day!Please try to re align the motor position.You have to do is repeat the procedure that you take to remove the motor and double check the alignment because all motor in misalignment is very hard to turn.And ... Vacuums

I have an old Friedland door chime (approx 30 years old). It has 5 terminal screws to connect wires. They are labeled 0-4. I removed the chime during remodeling and would really like to reuse it. I did not label the wires and where they connect when I removed it. I can't figure out how to wire it. I contacted Friedman and they were of no help... didn't have information on chimes that old. Can you help with how to wire the chime given it has five connections screws with no labels other t


... Vacuums

I have a motor for the Bissell 3750 power head with a black and brown wire, which wire is connected to what?? The old motor just had 2 black wires. There is a blue wire coming from the vacuum and blue wire coming from the light that are together, and a blue wire coming from the light and a black wire that are together. What does the blue and brown wire coming from the motor connect too? Thanks


... Bissell 3750 Lift Off Bagless Upright Vacuum

Kenmore Model 116 Cannister Vacuum.Trying to get into motor area. Think belt is worn out. I have removed the front two screws under the hinged cover, but can not remove cover over motor.. Still attached at rear. No evidence of any more screws to remove.


Under the cordwinder actuator button, are your other two screws. To remove this cover, take a flat tipped screwdriver and , very carefully, find the "tabs" (there are two) both on the front section under the button. Then, Carefully, press them in a ... Vacuums

Local vacuum repair shop replaced motor in Oreck XL 2600HH and now the lights blow out immediately upon powering up the machine. I believe the wires for the lights were mis-wired to the terminal blades on the motor housing. is there a wiring diagram available to properly connect the wires to the motor housing?


Hello. if this repair just occurred return this vacuum to that repair shop as they owe you a valid repair. I agree that they caused the lights blowing out problem. They must repair this for no charge. If you work on it yourself they will blame yo ... Oreck XL2600 Vacuum

Oreck XL9100 Our vac motor was removed to remove a hairpin in the motor.? The tape fell off the wires. Do you have a wiring diagragm?


See diagrams ... Oreck XL Ultra Bagged Upright Vacuum

I Have a kenmore 116.23612300 canister vacuum which will not start. I have power everywhere but nothing going to the black wire to the motor. Seems to stop at the pcb asm, #KC86WBZRZ000 . Nothing from there to the black motor wire. White wire to motor has continuity everywhere it should. Ruled out just about everything but the PC board. What does it do exactly?


... Kenmore 23612 Progressive PowerMate Bagged Canister Vacuum

Wiring Just removed hair, etc and had to remove the motor and clipped the light wires. Reinstalled but blew lights. Wired series> wired parallel> deffinetly wired wrong have a diagram?


First, what is the model number? I'll shoot you a wiring schematic. ... Oreck XL Ultra Bagged Upright Vacuum

The pump motor in my Bissel Proheat 2x Plus seems to have failed. It was seized so I sprayed WD-40 in it and let it sit for 3 days. Now I can turn it by hand, but when plugged into the unit it still doesn't spin. Here's a picture: http://bbay.dreamhost.com/bissel_proheat_2x_plus/P1070021.JPG I wanted to take the motor out and hook it into another power source to see if I can get it going but it has 3 wires. I'm used to only 2 (+ and -). How can I hook the motor up to another power source,


... Bissell Vacuums

No suction I have the central vac type. It has no suction at the can. I pulled the hose going to the walls and tested there...and nothing. I removed the dirt can and checked the motor ...it is spinning but does not feel like any suction. I checked the exhaust and it is pushing strong air out. I also cleaned the filter and still nothing. Is there a relay or something that would cause only exhaust air. I emptied the can of dirt and put it back together and have absolutely no air.....hear the motor


On some units there is a screen that protects the impeller of the motor. If this gets sealed off with debris then it is like putting a potato in the tail pipe of a car. Taking the top off the unit reveals the motor. DO UN-PLUG the unit first from th ... Electrolux Central Vacuum
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.mictaservice.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0946 seconds