Having problems with your Sebo X4 Bagged Upright Vacuum ?

Power Cable wires exposed where it enters handle

\015 Can i dismantle to refix wire and how\015

Answers :

Part of your question has been cut off by the FixYa system, but I guess you say the wires are exposed where the flex enters the handle. To dismantle the handle, first remove the handle from the machine and, of course, be sure the flex is not plugged in to the mains power. \012
\012Look on the back of the handle - you will see a small screw. Undo that screw and remove it, then you will be able to pull the plastic part of the handle out from the metal part. NOTE: it does not come very far out - just far enough so you can separate the two halves of the plastic part. When you've done that, it's only a matter of removing the damaged part of the flex (noting how the wires are routed inside the handle), stripping the remaining flex to match the bit you've removed, and wiring it in. Fit the two plastic halves together again (one hooks into the other at the top), push them down into the metal part and refit the screw. Job done!\012
\012If you need more help, just post a reply here and I'll get back to you soon. Good luck!
Repair Help & Product Troubleshooting for Sebo X4 Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Power Cable wires exposed where it enters handle


Part of your question has been cut off by the FixYa system, but I guess you say the wires are exposed where the flex enters the handle. To dismantle the handle, first remove the handle from the machine and, of course, be sure the flex is not plugged ... Sebo X4 Bagged Upright Vacuum

Hoover Vacuum My Hoover cannister model s3614 "runabout powermax" suddenly lost power to the agitator roller in the rug brush. Where the wire cord enters the power brush, the covering has rubbed off exposing the wires which are not bare but still have their own covering. For a while the power came and went as I manipulated the wires but finally died. Is this something I can fix myself or is it going to be an expensive professional repair? (Warrantee has elapsed.) Thanks.


Our Hoover upright vacuum cleaner makes a very loud noise when it is running. What causes this? ... Hoover S3614 Vacuum

Oreck Upright Hi Redev, I'm not sure what model I have (about 6 years old...upright, looks like the one in the picture). I changed the belt (which was torn) and then the next time I used it, it cut off on me. Now if won't turn on at all. (I turn the switch on and off and nothing happens as if it is not plugged in but it is!). I noticed at the top where the power cord enters the handle, it is all frayed. Could the electrical wires have detached? Anything you think I should check before taking it


The cord could be bad and will ahve to be replaced. It would have to have a problem inside the handle or down by the motor. ... Oreck XL2600 Vacuum

The brush wouldn't work when the selector switch was in carpet mode. Took the power head apart and removed the motor. Everything o.k. in the power head. Checked and found that the neutural wire had pulled out of the connector, the connector was never crimped at the factory. What a day! Took 2 hours and a large pizza to get it done. Neutral wire was in the hose just below the handle. Reconnected the wire and crimped it, put everything back together. It works!!!!


Great. ... Kenmore Vacuums

Spare wire? My SEBO X4 flex had to have the fex shortened because the cable sheathing had come out of the internal gripper and there was a couple of inches of two strand wire hanging out the cable entry point before the insulation sheathing started. No problem doing this but on the live switch terminal there was a piggy back spade connector. The second wire from this went down inside the handle and just ended with a bare terminal hanging in space. It hadn't come off anything, there wasn't anyth


Greetings from GoVacuum.com,I took a picture of the Sebo X4 wiring in the handle of the machine for you. This is a brand new machine taken out of the box, this is how the wiring should look. You'll see that there are 5 total wires here. ... Sebo Automatic X1 Bagged Upright Vacuum

We have had the power wires that run through the swivel elbow at the end of the main handle extensions and the power head break after being repaired two times. The new swivel elbow and wiring connection was installed bya local, non-electrolux vacuum shop each time. What is the trick?


Have them replace at the Aerus Electrolux shop. Aerus uses a higher grade plastic (Lexan, read about it on the net) which should last the life of the the power nozzle and wands. The part and labor will have a 1 year warranty. ... Electrolux Epic 6500 Vacuum

We have a Kenmore canister vacuum cleaner 25614504. It has in intermittant light and power flicker in the power mate unit as it is moving over the floor. This behavior can be simulated by jiggling the power cord where it eners the power mate. I do not know how to enter the power mate to see if there is a loose wire.


... Kenmore 28614 Canister Vacuum

Hello, I,ve just bought an Italian designed 3 bulb 70's wall lamp. It has a 2 wire lead feeding out with 2 wire lead running from one bulb socket To the other 2 inside the casing. I'm trying to wire it in my porch which has 3 wire cable coming from a 13amp plug for power. Any suggestions on making this work please ?


... Vacuums

HOW DO I CHANGE THE MAINS POWER CABLE ON A DYSON DC07? my wife cought the cable under the dyson and has stripped it to bare wires so i need to change the cable. i have taken a cover off near where the cable goes into the machine but now cannot get any further


How to open the cover near the cable for dyson upright vacuum ... Dyson DC07 Bagless Upright Cyclonic Vacuum

E series power head handle, internal wire came lose


Here is a pix.\015\012\015\012 ... Rainbow E series Canister Wet/Dry Vacuum

Dyson DC04 i have a loose wire where the cable enters the cleaner how do i open the part where the on/off button is. A wire is loose probably but I cannot get to the interior to check its status. How can I take it apart? the plug is sealed but could it be a loose wire in there?


You have to remove the yellow switch but to do this there is a small hole at the side of the switch nearest to the machine you have to push something in this which will push the clip that is holding the switch if you can do this there is a screw behi ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

Power head handle wiring


That wire goes just above where the trigger is, take the trigger out and there is a slot that the end goes into. ... Rainbow E series Canister Wet/Dry Vacuum

Kenmore canister model 116.25513506 wont turn on. when handle switch is turned to floor. vac motor does not turn on. When switch is turned to carpet, floor nozzle works but vac motor does not. I checked fuse, all o.k. checked continuity for plug, o.k. removed wires for bag full switch...motor wont run. I wired motor directly power cord...motor runs. Thinking it must be the circuit board, how do I bypass it or test it?


... Vacuums

Hi, the main box where all the wires connect to the sensor has the power on, and i've just noticed the small box where you enter the code to set the alarm does not work, yet the buttons are illuminated, normally the led light displays to show the power but no led's are on, the buttons doesn't work to set the alarm. Can you please hepl, many thanks.


Difficult as you didn't say what the equipment is but it sounds like there is a problem with communication between the main box and the keypad box. Have someone check that all the wires in the keypad are connected and there is no break in one of the ... Vacuums

WH5205 upright vacuum power cable replacement. How do you get at the cable connections inside? HELP! :(


... Hoover Vacuums

Dyson DC04 i have a loose wire where the cable enters the cleaner how do i open the part where the on/off button is.


If it is at the on/off switch, you can carefully prise the yellow button out to reveal a torx headed screw. Remove the screw then the housing for the switch can be pulled out which should reveal your loose wire.\015\012\015\012Brian ... Dyson DCO7 Animal Bagless Upright Cyclonic Vacuum

I have power at top of handle, thus start button light up. but when turn on nothing happens. I checked wiring and it all seems plugged in. The lights on the bottom of the cleaner (part of the base) don't light up. so somehow it makes since issue at base. HELP.. retired cop


Hi,\015\012Seems, the motor of vacuum has no power supply ( not connected yet). You may have a loosen/defective connection on motor cables/terminal. Please check and have it fixed. ... Oreck XL2200 Bagged Upright Vacuum

Power head handle wiring


Ok it is a grounding wire and it hooks to the place under the switch and then it hooks over the metal part of the wand where it slips into the plastic sleeve. ... Rainbow E series Canister Wet/Dry Vacuum

E series power head handle, internal wire came lose


Think it comes off of the hose. Maybe it broke off. ... Rainbow E series Canister Wet/Dry Vacuum

Sebo has become erratic in electrical power and today I have sparking from the top of the electrical lead where the wire goes into the handle. Can this be fixed?


Yes it can be fixed. If you are handy or someone in the house is handy you may even be able to do this yourself. All that is required is to remove the one screw out of the handle there near where the cord goes into the machine ... Sebo X4 Bagged Upright Vacuum

How to open 116.23512301 vacuum canister AC section to wire in replacement 4370608 cable assy. This assembly contains the receptacle that powers the hose. I found the two screws below the bag cover, but can't figure out how to release the end near the retractor lever.


... Kenmore Vacuums

Kenmore progressive mod. 116.25615500 vacum cleaner. Wire harness pulled out of handle and is on the power brush. Can iI just reinstall it harness is still in good shape? Thank you


... Kenmore 25614 / 25615 Progressive Bagged Canister Vacuum

DC07 DYSON REPLACEMENT HOSE. HOW DO YOU REMOVE IT FROM THE HANDLE. I have a kenmore whispertone 8540 canister vaccum. The electrical wires (3) to power the beater are embedded in the hose, in a spiral fashion. The yokes that hold the hose on both ends (and attach to the beater on one end and the unit on the other) have no screws or pressure latches; i don't want to use brute force as i may damage the attachment device inside the yoke. If someone can tell me the trick to get these yokes off each


Should be a pry off dot on the underside revealing a screw ... Vacuums

Royal vacuum cleaner model 4600 wiring diagram I have a Royal Vacumm Power Tank Model 4600. I replaced the switch (6 wire - 3 position) that is on the tank. One side of the switch control just the blower. The other side control the blower and the POWER head - wand with a variable control speed. The middkle position is off. After I installed the swith, the power head - wand is powered in either position. There are three wires comming out of the wand: White, Red and Black. I guess I wired somethin


... Vacuums

The power brush floor rug attachment on my Eureka 6997 A Oxygen Canister Vacuum goes on an off as I use it. I replaced the The power cord from the handle has 2 plug in connections: 1 at the handle / upper wand 1 at the lower wand top of the power brush attachment I replaced the entire wand assembly and it worked great for a year or so and now it's doing the same thing again. I was told to keep the power switch on the handle set to off when connecting the power brush attachment or it will bu


This is from the prongs not making a good connection causing an arch inside the plugg causing what looks like rust on the plugg. I would try snugging up the connection by squeezing the female section to get a better connection on the prongs when it i ... Vacuums