Having problems with your Sebo X4 Bagged Upright Vacuum ?

Sebo has become erratic in electrical power and today I have sparking from the top of the electrical lead where the wire goes into the handle. Can this be fixed?


Answers :

Yes it can be fixed.

If you are handy or someone in the house is handy you may even be able to do this yourself.

All that is required is to remove the one screw out of the handle there near where the cord goes into the machine. Cut the cord off the unit about 2 inches from the handle.
Open up the handle and follow where the cord goes to, and disconnect the cord from the switch. Both the white and the black will go to the switch.
Feed the cut cord through the handle.
Bare off about 1 and 1/2 inches of the cord you just cut, bare off the black and white and replace onto the switch.
Reassemble everything and you should be ready to rock and roll again.

Good luck.
Mark
Repair Help & Product Troubleshooting for Sebo X4 Bagged Upright Vacuum

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Sebo has become erratic in electrical power and today I have sparking from the top of the electrical lead where the wire goes into the handle. Can this be fixed?


Yes it can be fixed. If you are handy or someone in the house is handy you may even be able to do this yourself. All that is required is to remove the one screw out of the handle there near where the cord goes into the machine ... Sebo X4 Bagged Upright Vacuum

Oreck Upright Hi Redev, I'm not sure what model I have (about 6 years old...upright, looks like the one in the picture). I changed the belt (which was torn) and then the next time I used it, it cut off on me. Now if won't turn on at all. (I turn the switch on and off and nothing happens as if it is not plugged in but it is!). I noticed at the top where the power cord enters the handle, it is all frayed. Could the electrical wires have detached? Anything you think I should check before taking it


The cord could be bad and will ahve to be replaced. It would have to have a problem inside the handle or down by the motor. ... Oreck XL2600 Vacuum

Vacume did not come with screws to hold handle to Vacume need the screws handle falls off vacume hits the floor [email protected] Model # 3041 Type - B2 The answer is simple, send the screws please this will fix the problem. Thanks Dr.Tracy Massie Dr.Tracy Massie Harvard;Dr/PHD; Chief Officer of Internal Medicine;Lead Surgeon Dr. Child Disorders; Princeton Dr. / PhD.; Chief Medical Officer; Lead Councilor


... Eureka 3041BZ Upright Vacuum

Hoover wiring the blue wire that is in the lead that runs from the hoover to the plug that goes in the wall has come loose at the hoover end and has come out of the actual hoover. i've unscrewed it but am unsure as to where the blue lead (bare copper) needs to be screwed... if you see what i mean?!!


Hello lukeplayer,\015\012Based on your description, ( first disconnect the plug from the wall recptacle).You will need to open up the Hoover Vacuum Body to gaion access to the internal wiring. In order to better assist you, please provide me wi ... Hoover Vacuums

The power brush floor rug attachment on my Eureka 6997 A Oxygen Canister Vacuum goes on an off as I use it. I replaced the The power cord from the handle has 2 plug in connections: 1 at the handle / upper wand 1 at the lower wand top of the power brush attachment I replaced the entire wand assembly and it worked great for a year or so and now it's doing the same thing again. I was told to keep the power switch on the handle set to off when connecting the power brush attachment or it will bu


This is from the prongs not making a good connection causing an arch inside the plugg causing what looks like rust on the plugg. I would try snugging up the connection by squeezing the female section to get a better connection on the prongs when it i ... Vacuums

I have an open in the black wire leading down to the carpet sweeper (after the handle), thus the motor wont turn on. how do i get to the wiring to re-run a black wire?


Did you test the wire with the switch in the "ON" position. If not, try it before opening the handle. \015\012The problem is more likely to be a worn out or broken switch, including a reset switch.\015\012Also try connecting the hose di ... Kenmore 28015 Bagged Canister Vacuum

We have Nilfisk Tempest 1500W bagged cleaner. It just stopped working and I have taken off top cover and all wires/contacts look OK. But power still not getting through I assume. The retractable lead goes into base and cant get to this area. How do I check main lead or perhaps you provide details of serviceman. On North Shore, Auckland, NZ.


... Vacuums

RIVAL electric counter top fry pan. 16"x12" No heat, the indicator light goes on. Never exposed electric parts to water.


I am assuming the appliance you mention is the one at this site.\015\012\015\012It is likely the thermos ... Vacuums

Cleaning solution does not come out of the rotating cleaning head or the hand-held nozzle the solution pump seems ok but does not run (electrical continuity check between the two leads on the pump show very low resistance so they seem to be intact) - no dirt or blockage is apparent (it is a very simple device with 1 moving part wires to the pump also pass a continuity check THERE IS NO VOLTAGE on the pump leads from the control circuit board when I turn on the "manual" cleaning mode - a


You can contact Bissell directly at the following\015\012\015\012For UK inquiries:\015\012Monday - Thursday 9 am — 5 pm\015\012Friday 9 am — 4 pm\015\012\015\012BISSELL Homecare (Overseas) Inc ... Bissell SpotBot Robotic Wet/Dry Vacuum

I have a Wertheim 4808 Barrel vacuum cleaner that has suddenly stopped working. I believe that there is a problem with the electrical cord connection inside. I have tried unsuccessfully to open the compartment that leads to that area. One side unscrewed with a phillips head screwdriver but the other side seems to have a different type of fixing screw that I am unable to undo. It is awkward to get at and in a deep slot and the head of the fixing screw? is not visible.


... Vacuums

Nutone Broan CV556 runs continuously and will not shut off until I unplug it.. I disconnected the low voltage wires and it still runs when I plug it in. Inside the top of the vacuum are 3 electrical devices - one looks like a transformer wire -- one is a rectangular electronic black box. The third is an on off rocker switch. Which piece it likely to be shorted out? It is about 8 years old.


... Broan-NuTone CV556 Cyclonic Bagless Central System Vacuum

Electrical My Kirby Ultimate G won't turn on when it is supposed to, sometimes it will and sometimes it won't ...also I see greenish blue sparks in the machine where the handle attaches to the motor when it is on. As a side note, the shampoo attachment won't make suds anymore.


\015\012PROBLEM: THE KIRBY WILL NOT TURN ON AT ALL\015\012POSSIBLE CAUSES: \015\012\015\012\015\012Please note......The Kirby has TWO safety switches that need to be engaged before it will operate. One is on ... Kirby Ultimate G Bagged Upright Vacuum

DC07 DYSON REPLACEMENT HOSE. HOW DO YOU REMOVE IT FROM THE HANDLE. I have a kenmore whispertone 8540 canister vaccum. The electrical wires (3) to power the beater are embedded in the hose, in a spiral fashion. The yokes that hold the hose on both ends (and attach to the beater on one end and the unit on the other) have no screws or pressure latches; i don't want to use brute force as i may damage the attachment device inside the yoke. If someone can tell me the trick to get these yokes off each


Should be a pry off dot on the underside revealing a screw ... Vacuums

Mrs Cleaner flex has pulled out how do I replace Electric supply wire to switch on handle has broken at switch. How do you remove switch to repair? tonysimmons


Hi\015\012\015\012\015\012\015\012\015\012\015\012\015\012 ... Dyson DC07 Bagless Upright Cyclonic Vacuum

I have power at top of handle, thus start button light up. but when turn on nothing happens. I checked wiring and it all seems plugged in. The lights on the bottom of the cleaner (part of the base) don't light up. so somehow it makes since issue at base. HELP.. retired cop


Hi,\015\012Seems, the motor of vacuum has no power supply ( not connected yet). You may have a loosen/defective connection on motor cables/terminal. Please check and have it fixed. ... Oreck XL2200 Bagged Upright Vacuum

I have a shark iron model G1495N It has a cut in the wire inside the rubber hosing that goes around the cord from the base of the iron When using it yesterday I didn't see the cut and it sparked after plugging it in and heating up Is not usable at all What can I do to repair it if at all? I've had it since sept 2008 Thnxs


It's probably best to replace the device, when dealing with sparks and exposed wires. \015\012\015\012If you're electrically-inclined, feel free to pry it apart (when unplugged!) and see if you can re-attach things, but generally soldering or g ... Vacuums

I just received a Sharper Image SI724 Hybrid GP air purifier and it will not turn on. There is a green light that comes on at the bottom front of the unit, but the light on the top do not show any color and do nothing. I have tried to clean the fine wires to no avail. Is it just a bad unit or is there an in-home fix I could use?


If you just got it and it doesn't work ... you should return it for an adjustment. If you fool with it, you will probably void any warranty there may be on the device. ... Vacuums

Dyson DC05 It is a vaccum cleaner in a perfect condition but recently developed a problem. It sparks and sometimes power goes off while operating. It is clear that the wire is loose but do not know how to open the bracket of the main button on the machine. [email protected]


Hi \015\012try this site http://dysonmanuals.llc.nu/\015\012\015\012It has service manuals for the DC05. ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

We have a rainbow e series and in the process of cleaning it, the top came off and the 4 black, red, gray and white wires cam off of thier clips. We see where each connects but don't know what color goes where. Can you help us?


Still need help?\012\012Let me know, Ok :-)\012\012Ralph ... Rainbow E series Canister Wet/Dry Vacuum

When running the 2100 Electrolux vacuum, it is stopping and starting when pulling or pushing the floor attachment. Seems like the connection at the top of the handle is a little loose or the electric tabs are loose where the hose connects. Any ideas?


Other option is that on the hose end of the electrical connection, you can use an awl on the electrical connections to bend them in slightly so they make good contact when they are automatically plugged in when you connect the wands. HOWEVER, ONLY D ... Electrolux UltraLux 2000 Bagged Canister Vacuum

The drive/neutral lever on my Kirby 2000 G fell off. How do I fix it? I disassembled it removing the the top covering the motor and the bottom where the lever goes in, now I'm kinda stuck...


... Kirby G6 Bagged Upright Vacuum

My Dyson DC20 motorhead vacuum has a blocked hose - how can I unclog this? I think there is a sock caught up by the handle. The hose has electrical wires running through it so I cannot cut the hose.


Usually a plugged hose can be cleared using a broom handle, if you can force the blockage through, if not as previously suggested a coat hanger attached to the broom handle (duck tape will do) straighten out hanger so it can be used like a cork screw ... Dyson DC05 Cylinder Bagless Canister Cyclonic Vacuum

How do I change the outer bag clip? Can't figure out how to get the top apart to put in the new clip. The clip that goes to the handle.


I had a Kirby Classic and I had to slide off the clip.Don't rate me if this doesn't work. ... Kirby Generation 3 Bagged Upright Vacuum

My dyson dc animal's brush is not spinning. The machine smells like burning rubber. I believe the clutch has gone out but the machine also only sucks from the top of the hose in the handle. I am wondering if the machine is not locking properly which is causing the brush to not need to spin. If this is the problem how do i fix this problem.


... Dyson DC14 Animal Bagless Upright Cyclonic Vacuum

I have a hoover power scrub steamvac, the main soap dispenser trigger on the handle click when pressed and does not work (broken spring??) the other soap triggers on the hose and the trigger on top to dispense extra water both work. Can I fix the main trigger myself?